My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2020 4:37:47 PM
Creation date
9/18/2020 2:54:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O A Q U I N Environmental Health Department <br /> C ©U y'r Y-- <br /> Underground <br /> -Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Fast Lane Central Valle 116 Roth Rd, LathropJune 05, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to <br /> be tested. <br /> The Diesel#3 and Diesel#4 on the truck side spill containers had approximately 5 gallons of standing liquid when the <br /> inspector arrived on site. The spill container did not meet the five gallon capacity with the standing liquid. The service <br /> technician removed the stating liquid prior to the testing and verified the five gallon capacity without the standing <br /> liquid. All spill containers shall have a minimum capacity of five gallons and be capable of containing a spill or overfill <br /> until it is detected or cleaned up. The service technician removed the standing liquid while the inspector was on site <br /> to correct this violation. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations, title 23 division <br /> 3, chapter 16 section 2635(c)(2) shall test overfill prevention equipment once by October 13th, 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair. The site conducted the test on 1/25/19, over three <br /> months late. Ensure to conduct overfill prevention equipment inspection within the time frame provided by the <br /> regulation and submit test results within 30 days of performing the inspection. Overfill prevention equipment <br /> inspection is required once by October 13th, 2018 and every 36 months thereafter. Take all necessary precautions <br /> to ensure testing is performed in a timely manner. Ensure a 48 hour notification is provided to EHD prior to <br /> conducting the inspection. Test result for the testing performed must be submitted within 30 day of testing. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator at the time of inspection. The EHD will generate and <br /> provide a complete report to the facility operator. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: June 24, 2019 Inspector: Inspector Phone: <br /> Printed Name and Title: ZUNA BARKER, REHS (209) 953-7311 <br /> FA0015977 PR0523684 SCO01 06/05/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 10 of 10 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.