Laserfiche WebLink
SAN" J D�l+ �� I 11411" Environmental Health Department <br /> COUNTY— <br /> Underground <br /> �l O U N T Y-- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RANCHO SAN MIGUEL MARKET* 610 S Cherokee Ln Lodi Joctober 16 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 2641(b) <br /> 402 CCR 2643(d) Failure to conduct monitoring/maintain records for single-walled conventional suction(pre-1984) ❑V ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) 0.1-gph line test for single-walled gravity piping not performed biennialy or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) 71 <br /> Item# Remarks <br /> 106 CCR 2632(d)(2), 2634(e)Failed to have an approved UST response plan. <br /> The response plan is not current not approved by the EHD. <br /> -The response plan found on site was dated 10/7/2019 while the response plan found on CERS was dated 5/8/2018. <br /> The response plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log into <br /> CERS, upload the completed form, and submit for review by the EHD. <br /> This is a minor violation. <br /> 118 CCR 2715(a)(1)(A), 2715(a)(2) Failure to submit the"Underground Storage Tank Statement of Understanding and <br /> Compliance Form". <br /> The Underground Storage Tank Statement of Understanding and Compliance Form was not found in CERS. This form <br /> must be uploaded to the California Environmental Reporting System (CERS). Immediately log into the California <br /> Environmental Reporting System (CERS)at http://cers.calepa.ca.gov and upload the Underground Storage Tank <br /> Statement of Understanding and Compliance Form for this facility. <br /> This is a minor violation. <br /> 201 CCR 2712(b)(1-2)Failure to maintain monitoring, maintenance, and follow up action records. <br /> The following maintenance and monitoring records for the last three years were not found on site: <br /> -2016 Monitoring System Certification <br /> -2018 Monitoring System Certification <br /> -Overfill Prevention Equipment Test results(10/16/2018)(corrected on site) <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of all <br /> monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual <br /> observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6)results of inventory readings and <br /> reconciliations. Immediately locate and maintain all missing maintenance and monitoring records for the last three <br /> years on site and submit copies to the EHD. <br /> This is a minor violation. <br /> FA0014852 PRO521866 SCO01 10/16/2019 <br /> EHD 23-01 Rev.08/27/2019 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />