Laserfiche WebLink
SAN ` ' J o H Q U ( 1 \ Environmental Health Department <br /> C () U N T - RECEIVED FEB 212019 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address: bate : <br /> CHEVRON STATION #212470/2222` 3400 MACARTHUR DR , TRACY February 21 , 2019 <br /> File Review <br /> 123 CCR 2637. 1 (d), Failure to submit the "Spill Container Testing Report Form" within 30 days after the test ❑ V ❑ R ❑ COS <br /> 2637, 1 (e) <br /> 124 CCR 2637. 2(d&e), "Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days of inspection c V o R ❑ COS <br /> 2665(a&b) <br /> On Site Records + <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records QV ❑ R o COS <br /> 202 CCR 2715(c) (3), Failure to maintain the "Facility Employee Training Certificate" on-site (after October 1 , 2018) a V ❑ R ❑ COS <br /> 2715(c)(4) <br /> 203 CCR 2712(b) Failure to maintain records of repairs, lining, and upgrades on site, for the life of the UST c V o R ❑ COS <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site ❑ V ❑ R a COS <br /> 205 CCR 2712(i), 2634(e) Failure to submit a current UST Response Plan and have it available onsite ❑ V a R ❑ COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions <br /> o o ❑ COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment ❑ V ❑ R ❑ COS <br /> 208 CCR 2650(e), 2652 Failed to notify the EHD of a reportable unauthorized release and/or prepare a report o V c R o COS <br /> 209 CCR 2716(a•e) Failure to conduct the designated UST operator visual Inspection at least once every 30 days ® V o R o COS <br /> 210 CCR 2716(!) DO monthly reports not maintained on site for 12 months or for 36 months (after October 11 2018) c V ❑ R a COS <br /> 211 CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a DO o V o R ❑ COS <br /> 212 CCR 2715(0(2) Unstaffed facility failed to have or implement a training program approved by the EHD ❑ V ❑ R ❑ COS <br /> 213 HSC 25281 . 5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept ❑ V ❑ R o COS <br /> 214 HSC 25281 . 5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept c V ❑ R a COS <br /> 215 CCR 2712(i) Failure to retain a copy of the permit to operate at the facility <br /> cV a ❑ COS <br /> UST System Observations <br /> 301 HSC 25292. 1 (a) UST system is not operated to prevent unauthorized release, Including spills and overfills o V ❑ R o COS <br /> 302 HSC 25291 (b) UST system Incapable of detecting leak from primary into secondary containment (pre-Jul 2003) o V o R ❑ COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment (Jul 2003-Jun 2004) n V c R o COS <br /> 304 HSC 25290. 1 (d) Monitoring system not maintained to detect entry into secondarycontainment (after Jul 2004) o V ❑ R a COS <br /> 305 HSC 25290. 1 (e) VPH monitoring of the Interstitial spaces of the UST system is not maintained ❑ V ❑ R ❑ COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity ® V ❑ R a COS <br /> 307 CCR 2631 (g) , 2632(c) Monitoring system of the interstitial space of a double walled system not maintained i V ❑ R ❑ COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm t, V ❑ R ❑ COS <br /> 309 CCR 2636(f)( 1 ) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product r_; V c R o COS <br /> 310 CCR 2636(0(4) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs ❑ V ❑ R o COS <br /> 311 CCR 2638(a), 2641 Q) Failed to properly program, calibrate, operate, or maintain leak detection equipment o V ❑ R c COS <br /> 312 CCR 2638(01 2641 (i) Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced ❑ V ❑ R c COS <br /> 313 HSC 25290, It 25290.21 Failure to construct, operate, and maintain primary containment as product-tight ❑ V ❑ R ❑ COS <br /> 25291 <br /> FA00141ll PROM8738 SC001 02121 /2019 <br /> EHD 23,01 Rev. 09/28!2018 Page 2 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 ( F 209 464-0138 1 www, sjcehd . com <br />