COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 12:57:14 PM
Creation date
9/21/2020 10:28:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
CHEVRON STATION #212470/2222*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J O A Q U ( N Environmental Health Department <br /> ---- - C� uNTY--- �� RECEIVED FEB 21Zit <br /> � <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION #212470/2222` 3400 MACARTHUR DR, TRACY February 21 , 2019 <br /> UST System Observations <br /> 314 HSC 25290. 16 25290.21 Failed to have secondary containment or secondary containment not tight o V o R ❑ COS <br /> 25291 <br /> 315 HSG 25291 (e) Water in secondary containment not removed, analyzed, and properly disposed of (pre•Jul 2003) o V o R ❑ COS <br /> 316 HSC 25290. 1 (c3), Secondary containment not constructed to prevent water Intrusion (after Jul 2003) o V o R o COS <br /> 25290.2(c3) <br /> 317 CCR 2636, 2643(c)( 1 ) , Line leak detector (LLD) not installed ❑ V o R ❑ COS <br /> 2666(f) <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch o V o R o COS <br /> 319 CCR 2635, 2637. 1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested ■ V o R o COS <br /> 2665, 2712 <br /> 320 CCR 2635, 2637. 2, Failure to comply with the installation, inspection , or record keeping of the overfill prevention v V o R ❑ COS <br /> 12665, 2712 <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden o V o R ❑ COS <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status o V ❑ R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑ V o R o COS <br /> 324 CCR 2717. 1 (g) Tampered with red tag o V ❑ R o COS <br /> 325 CCR 2717. 1 (0 Deposited petroleum into a red tagged UST o V ❑ R o COS <br /> 326 NSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V OR o COS <br /> 327 CCR 2631 . 1 UST system not compatible with the substance stored o V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V ❑ R o COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements o V o R o COS <br /> 330 CCR 2636(Q, 2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm c V ❑ R o COS <br /> 2666(f) <br /> 331 CCR 2630(d), 2641 (a) Liquid does not flow into the sump in the event of a leak (i .e., failure to remove test boot). c V o R o COS <br /> 332 CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards v V o R o COS <br /> 2666(b&e) <br /> 333 CCR 263512636(b) , Failure to comply with the cathodic protection system requirements u V ❑ R o COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single•walled pipe not upgraded to double-walled interstitially monitored pipe during repair u V ❑ R o COS <br /> 335 CCR 2630, 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an Independent third-party c V o R o COS <br /> 2644. 1 <br /> Single-Wailed Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve r._ V ❑ R o COS <br /> 2641 (b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984). c V o R o COS <br /> 403 CCR 2643(d), 2661 (f) Failure to conduct 0. 1 gph test for single-walled conventional suction systems (pre•Jan 1984) c V ❑ R ❑ COS <br /> 404 CCR 2643(e) , 2661 (0 Biennial 0. 1 gph line integrity test for single-walled gravity piping not performed (pre•Jan 1984) c V u R ❑ cos <br /> Other Violations <br /> 2010 See below Unlisted General violation <br /> u ❑ R (3 COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS l; CLASS 11, or MINOR% ^ Notice to Comply) <br /> FA0014111 PR0518738 SCO01 02/21 /2019 <br /> EH0 2MI Rev, 09!28/2016 Page 3 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 1 www. sjcehd , Com <br />
The URL can be used to link to this page
Your browser does not support the video tag.