My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2050
>
2800 - Aboveground Petroleum Storage Program
>
PR0516363
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2020 10:48:28 AM
Creation date
9/22/2020 8:04:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0516363
PE
2832
FACILITY_ID
FA0010987
FACILITY_NAME
TEC Equipment
STREET_NUMBER
2050
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
Ave
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
2050 E Louise Ave
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
158
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
28 October 2020 AdvancedGeo <br /> Project No. 20-6092 An Employee-Owned Compony <br /> Page 6 of 20 <br /> within UL 142 listed tanks with secondary containments built-in within the warehouse. The <br /> approximate locations where oil is stored are illustrated in Figure 2. <br /> Type Capacity Contents Location Active <br /> (Gallons) <br /> Horizontal Double 250 feet southwest of <br /> Wall Steel AST 6,000 Diesel the building at the west Yes <br /> (UL Listed) perimeter <br /> Horizontal Double 250 feet southwest of <br /> Wall Steel AST 6,000 Diesel the building at the west Yes <br /> (UL Listed) perimeter <br /> Double Wall Steel 1,000 New Motor Oil Southeast of Shop Yes <br /> AST (UL Listed) <br /> Double Wall Steel 120 New Motor Oil Southeast of Shop Yes <br /> AST (UL Listed) <br /> Double Wall Steel 1000 Used Motor Oil Southeast of Shop Yes <br /> AST (UL Listed) <br /> 55 Gal Drums 55 x 8 Drums Waste Filters Southeast of Shop Yes <br /> (approximately) <br /> Approximate Total: 14,560 <br /> 4.0. DISCHARGE PREVENTION - GENERAL SPCC PROVISIONS <br /> The following measures are implemented to prevent oil discharges during the handling, <br /> use or transfer of oil products at the Facility. Oil-handling employees have received <br /> training in the proper implementation of these measures. <br /> 4.1. COMPLIANCE WITH APPLICABLE REQUIREMENTS - 40 CFR 112.7(a)(2) <br /> The two 6,000-gallon ASTs are UL-listed double-wall cylindrical vessels that are <br /> manifolded together and positioned horizontally within a concrete secondary <br /> containment. The concrete secondary containment has the capacity of approximately 104 <br /> cubic feet or 775 gallons. A spill-kit containing absorbent materials is located between the <br /> AST's and the fuel dispensers for quick use, if needed. Two fire extinguishers are <br /> mounted on a column and are within 20 feet from each end of the AST and dispensers. <br /> Approximately ten (10) fire extinguishers are located in the office, maintenance shop and <br /> in the petroleum storage areas. <br /> The petroleum storage tanks on the property are either double walled or are placed on <br /> spill pallets. <br />
The URL can be used to link to this page
Your browser does not support the video tag.