Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.sjgov.orcI/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VALLEY PACIFIC HWY99 CARDLOCK 3550 S HWY 99 STOCKTON January 04 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> -2018 test results were not found on site, including monitoring system certification (1/18/18), secondary containment <br /> testing (1/18/18), and overfill prevention testing (10/26/18). <br /> -Alarms logs and/or work orders were not found on site for the L1 (87 STP sump)fuel alarms on 3/14/18 and 4/16/18. <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of all <br /> monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br /> observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> site and submit copies to the EHD. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to document all the alarms from the attached alarm history on the March and April 2018 <br /> designated operator monthly inspection reports and failed to check that they were responded to appropriately. The <br /> missing alarms include: L1 (87 STP sump)fuel alarms on 3/14/18 and 4/16/18. During the monthly inspection, the <br /> designated operator shall review the alarm history for the previous month, check that each alarm was documented and <br /> responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br /> including all of the required information on the reports. <br /> This is a minor violation. <br /> 309 CCR 2636(f)(1) Monitoring in sump/ UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo box float and chain in UDC 1/2 east failed to stop the flow of product at the dispenser when tested. All <br /> monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of product at the <br /> dispenser when it detects a leak. The service technician adjusted the float and bolts and verified functionality. <br /> This was corrected on site. <br /> This is a minor violation. <br /> FA0007030 PR0505827 SCO01 01/04/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 Of 5 Underground Storage Tank Program OIR <br />