My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 4:37:47 PM
Creation date
9/22/2020 1:43:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
FACILITY_NAME
H&S Energy Products,#3035
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMENDEDEnvironmental Health Department <br /> SAN JOAQUIN zg � ► 3o � iy <br /> cr � iai .l i �r <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date: <br /> Colonial Energy CE 40135 ( DBA Power Mart) 192 Lathrop Rd , Lathrop January 03 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 211 CCR 2715 (c) (2) No employee present that were trained in the operation and maintenance of the UST system by a <br /> D0 . <br /> The designated operator employee training for Casey Smith was not performed . The designated operator shall <br /> train facility employees for which he or she is responsible in the proper operation and maintenance of the UST <br /> system once every 12 months . The training shall include , but is not limited to : <br /> 1 . Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2 . Employee 's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3 . Employee ' s role with regard to spills and overfills as specified in the facility's response plan <br /> 4 . Name of the contact person (s) for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site , and submit a copy of <br /> the training records to the EHD . <br /> The designated operator that was on site , trained Casey Smith while the inspector was on site to correct this on site . <br /> This was corrected on site . <br /> This is a repeat violation , Class II . <br /> 301 HSC 25292 , 1 (a) UST system is not operated to prevent unauthorized release , including spills and overfills . <br /> A seepage was observed the fuel filter and meter located in dispenser 11 . The underground storage tank system <br /> shall be operated to prevent unauthorized releases . Immediately Immediately repaired or replaced by a properly <br /> licensed , trained , and certified contractor under permit and inspection of the EHD , if needed and provide proof of <br /> repair to EHD . <br /> This is a repeat violation , Class II . <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The diesel fill sump sensor was laying on its side at the top of the saddle of the tank and not located to detect a leak <br /> at the earliest opportunity. Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br /> possible opportunity. The sensor was relocated to the lowest point of the sump by the service technician . Ensure <br /> that all monitoring equipment is maintained to detect a leak at the earliest opportunity. <br /> This was corrected on site. <br /> This is a Class II violation . <br /> 307 CCR 2631 (g) , 2632 (c) Monitoring system of the interstitial space of a double walled system not maintained . <br /> The 91 product annular sensor failed to activate an audible and visual alarm when tested and , therefore , the tank is <br /> not monitored . The interstitial space shall be monitored with a monitoring system connected to an audible and <br /> visual alarm system . The sensor was replaced and retested during the inspection . A " UST Retrofit Verification with <br /> Inspector Already Onsite" form has been completed and provided to the operator and contractor. <br /> This was corrected on site . <br /> This is a Class II violation . <br /> FA0007059 PR0505867 SCO01 01 /03/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 I F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.