Laserfiche WebLink
MEH '� D <br /> SAN 10 A Q U I N Environmental Health Department <br /> IY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date: <br /> Colonial Energy CE 40135 ( DBA Power Mart) 192 Lathrop Rd , Lathrop January 03 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR = Notice to Comply) <br /> Item # Remarks <br /> 315 HSC 25291 (e) Water in secondary containment not removed , analyzed , and properly disposed of (pre-Jul 2003 ) . <br /> Liquid was observed in the diesel fill sump . If water could enter into the secondary containment by precipitation or <br /> infiltration , it must be removed and disposed of properly. The service technician removed the liquid from the diesel <br /> fill sump . Ensure that all sumps and annular spaces are maintained free of liquid . <br /> This was corrected on site . <br /> This is a repeat violation , Class II , <br /> 320 CCR 2635 , 2637 . 2 , 2665 , 2712 Failure to comply with the installation , inspection , or record keeping of the overfill <br /> prevention . <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations , title 23 division <br /> 3 , chapter 16 section 2635(c)(2 ) shall test overfill prevention equipment once by October 13th , 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair. The site did not performed the testing by October 13th , <br /> 2018 however the service technician on site was able to conduct the overfill prevention equipment inspection today <br /> ( 1 /3/19) while the inspector was on site. Ensure to conduct overfill prevention equipment inspection within the time <br /> frame provided by the regulation and submit test results within 30 days of performing the inspection . Ensure a 48 <br /> hour notification is provided to EHD prior to conducting the inspection . <br /> This was corrected on site. <br /> This is a Class II violation . <br /> Overall Inspection Comments : <br /> An inspection checklist was provided to the facility operator on the day of inspection . The EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> paperwork , within 30 days of receiving the complete inspection report . <br /> AFTER THE COMPLIANCE DATE , EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE . <br /> Received by: Date: January 30 , 2019 Inspector: Inspector Phone : <br /> Printed Name and Title: ZUNA BARKER , REHS (209) 953-7311 <br /> FA0007059 PR0505867 SCO01 01 /03/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 6 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />