Laserfiche WebLink
MEN ;�'p Environmental Health Department <br /> SAN 10AQUIN �� <br /> COUNTY-- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MAIN STREET ARCO AM PM* 1 1100 S MAIN ST, MANTECA March 27, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the all tanks are not current in CERS. The tank forms state under riser secondary <br /> piping to be None, during the field inspection secondary containment of the rise piping was observed. Any change of <br /> information must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the <br /> required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For all tanks,the monitoring plan stated that ELD <br /> testing is performed, however the operator Mr. Chadda had a letter from the Water Board stating that it was not <br /> required to perform ELD testing. Furthermore the 87 product Leak Detector listed in the monitoring plan is FE Petro <br /> MLD however VMI LD2000 was observed during the field inspection. Lastly the 87 product STP sump list sensor <br /> 323 however sensor 208 was observed during the field inspection.The monitoring plan must be uploaded to the <br /> California Environmental Reporting System(CERS). Immediately log into CERS, make the necessary changes, and <br /> submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 202 CCR 2715(c)(3),2715(c)(4) Failure to maintain the"Facility Employee Training Certificate"on-site(after October 1, <br /> 2018). <br /> Employees Timmy(No last name provided in the training log),Varinder Kuar and Brianna(No last name provided in <br /> the training log)were trained on 10/8/18 and the"Facility Employee Training Certificate"was not used to document <br /> the training. Furthermore the employee Hapreet(no last name provided in the training log)was trained on 12/3/18 <br /> and the date of assuming responsibility was on 11/30/18. Lastly the date of training for Hapreet and Jeet Sing were <br /> not provided.All site employees must be trained prior to taking responsibility as a facility employee if after October <br /> 1,2018, or within 30 days of hire if prior to October 1, 2018. the"Facility Employee Training Certificate"shall <br /> contain accurate information for all employees trained. Update the"Facility Employee Training Certificate"to contain <br /> the accurate information and submit a copy of the updated form to the EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(i)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> FA0007464 PRO506504 SCO01 03/27/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />