My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 11:25:17 AM
Creation date
9/22/2020 2:57:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMEnvironmental Health Department <br /> SAN JOAQUIN tiil�►c9 <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MAIN STREET ARCO AM PM` I 1100 S MAIN ST, MANTECA March 27, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> within the past 36 months?"The overfill prevention equipment inspection was scheduled to be completed on 3/27/19. <br /> On the 3/7/19 designated operator(DO)inspection report under <br /> -Section I <br /> The DO failed to write the CERS ID and zip code <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A from section VII through XI. <br /> -Section X <br /> The DO failed to mar YES, NO or N/A under the question"Are all sensors in containment sumps inspected located to <br /> detect a leak at the earliest opportunity?" <br /> -Section XI <br /> The DO failed to mark Yes or No to the question"Have all individuals performing facility employee duties received <br /> the required facility employee training within the past 12 months?" <br /> During the designated operator inspection,the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br /> history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing inspections at least once every 30 days at this facility and are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class II. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> In dispenser 9/10 in the 87 product fuel meter a seepage was observed, indicating a leak in the primary piping. All <br /> primary containment for the UST system must be tight. Immediately have a properly licensed,trained, and certified <br /> contractor repair or replace the failed component under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 91 product fill sump. If water could enter into the secondary containment by precipitation <br /> or infiltration, it must be removed and disposed of properly. The service technician removed approximately 1-2 <br /> gallons of liquid from the 91 product fill sump. Ensure that all sumps and annular spaces are maintained free of <br /> liquid. <br /> This is a repeat violation, Class II. <br /> FA0007464 PRO506504 SC001 03/27/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 7 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.