15 14 113 112 111 110 9 18 17 6 15 14 13 12 1 <br /> STANDARD FLAT WASHER <br /> A STEEL 4 BRASS PIPE HANGER SCHEDULE COPPER TUBE 4 PIPE HANGER SCHEDULE SCH 40 PVC 4 A55 PIPE HANGER SCHEDULE A <br /> HORIZONTAL SUPPORT HORIZONTAL SUPPORT HORIZONTAL SUPPORT <br /> N < PIPE W/ THREADED OR HE JOINTS SOLDER OR BRAZED JOINTS SOLVENT CEMENTED JOINTS <br /> 0 <br /> X 1Y4�� 3/a" MACHINE BOLT PIPE SIZE HANGER ROD MAX HORIZONTAL SPAN PIPE SIZE HANGER ROD MAX HORIZONTAL SPAN PIPE SIZE HANGER ROD MAX HORIZONTAL SPAN <br /> �n w 1/2" - 3/4" 3/8" 10' 1/2" - 1-1/2" 3/8" 6' 1/2" - 1-1/2" 3/8" 4' <br /> I" - 4" 3/8" 12' 2" - 4" 3/8" 10' 2" - 4" 3/8" 4' <br /> 6" 112" 12' 6" 112" 10' 6" 112" 4' <br /> ANGLE STEEL PIPE FOR WATER OR DWV THREADED OR WELDED JOINTS, COPPER TUBE AND PIPE WITH SOLDER, BRAZED OR WELDED JOINTS, COPPER TUBE AND PIPE WITH SOLDER, BRAZED OR WELDED JOINTS, <br /> B PIPE CLAMP, B-LINE SIZES DEVELOPED FROM TABLE 313.3 t TABLE 313.6 OF THE 2016 CPC. SIZES DEVELOPED FROM TABLE 313.3 t TABLE 313.6 OF THE 2016 CPC. SIZES DEVELOPED FROM TABLE 313.3 $ TABLE 313.6 OF THE 2016 CPC. B <br /> 62000 SERIES (TVP) PIPE SHIELD, THRU ALL PIPE SHALL BE SUPPORTED WITHIN 18" OF A JOINT. ALL PIPE SHALL BE SUPPORTED WITHIN 18" OF A JOINT. ALL PIPE SHALL BE SUPPORTED WITHIN 16" OF A JOINT. <br /> FIG. B3380CT THRU B3384 SEISMIC BRACING REQUIRED FOR: SEISMIC BRACING REQUIRED FOR: SEISMIC BRACING REQUIRED FOR: <br /> I. MEDICAL GAS, VACUUM PIPE, COMPRESSED AIR, FUEL PIPING, AND I. MEDICAL GAS, VACUUM PIPE, COMPRESSED AIR, FUEL PIPING, AND I. MEDICAL GAS, VACUUM PIPE, COMPRESSED AIR, FUEL PIPING, AND <br /> H4ANGER ROD, SEE OTHER HAZARDOUS PIPE I" DIA AND LARGER OTHER HAZARDOUS PIPE I" DIA AND LARGER OTHER HAZARDOUS PIPE I" DIA AND LARGER <br /> TABLE FOR SIZE 2. ALL PIPING 1-1/4" DIA AND LARGER IN BOILER ROOMS, MECHANICAL 2. ALL PIPING 1-1/4" DIA AND LARGER IN BOILER ROOMS, MECHANICAL 2. ALL PIPING 1-1/4" DIA AND LARGER IN BOILER ROOMS, MECHANICAL <br /> EQUIPMENT ROOMS, t REFRIGERATION MECHANICAL ROOMS EQUIPMENT ROOMS, t REFRIGERATION MECHANICAL ROOMS EQUIPMENT ROOMS, t REFRIGERATION MECHANICAL ROOMS <br /> 12" MAX. ADJUSTABLE BAND <br /> HANGER, 6-LINE 63680 <br /> HANGER ROD, SEE TABLE FOR SIZE a rc h i to cts <br /> C WASHER, B-LINE 6200 SERIES TIMOTHY P. HUFF & <br /> ASSOCIATES, INC. <br /> Timothy P. Huff, AIA Architect <br /> WROUGHT STEEL 519 McHenry Ave., Modesto, CA 95354 <br /> CLEVIS HANGER, <br /> Ph: (209)571-2232 Fax: (209)571-1936 <br /> B-LINE B3100 <br /> SES AFR?Cy <br /> 15/8" UNISTRUT BU I LP I NG D ONLY ���o�N� PA�< y���, <br /> HAN6ER <br /> I CW SUPPLY .� G� -A <br /> D1 2 4 PIPE ETA I i.. STAINLESS STEEL D * o. C 15 5 7 <br /> P0.2 SCALE: NONE AccEss DOOR ��� <br /> %2"CW OF <br /> ° ° ° ° Copyright 2019-Timothy P. Huff&Associates <br /> 7 <br /> w <br /> a ° ° °d ° <br /> v ° <br /> BALL VALVE <br /> E ° a ° ° E ne.Tus <br /> PRECAST CONCRETE 60X CLEANOUT engineering <br /> WITH COVER-LABEL "SEWER" [PLUG TRAP PRIMER <br /> 3 PAVEMENT Consulting Mechanical Engineers <br /> /I iinnninnniiiuiiiiiiiiiu1400 Lone Palm Ave,Suite A <br /> OR GRADE <br /> SEAL WITH MASTIC Modesto,CA 95351 <br /> Ill 6" I Tel:209.572.7399 Fax:209.236.1579 <br /> �� ���������������������������������������������������� �� 5 26 GA. GALV. SHEET METAL 12" www.n e x u s e n g i n e e r i n g.n e t <br /> 7 O 12" MIN. AFF UNION JACK-MATCH SLOPE�` MIN. HVAC.Plumbing/Piping.Fire Sprinklers <br /> F 6 18"xl8" POURED FINISH ROOFING F Process/Plant Engineering .Refrigeration <br /> CONCRETE ALL 1/8 BEND I <br /> I. FINISHED GRADE AROUND IN PIPE QRcjFESS/0N <br /> 2. BRONZE COVER UNPAVED AREAS SUPPORT <br /> 3. FLOOR DRAIN WYE BRANCH %2" COPPER TO FLOOR DRAIN <br /> TRAP PRIMER CONNECTION <br /> 4. CONCRETE FLOOR, REFER TO STRUCT PLANS CONTRACTOR TO SUPPLY I PLUMBING VENT, SEE 3 9 m <br /> FOR RECESSED SLAB LOCATIONS — ADDITIONAL FRAMING AS PLANS FOR SIZES 20 <br /> REQUIRED <br /> 5. NO-HUB CLAMP � <br /> PIPE SIZE AS CLEANOUT PLUG 1 �FCHA14 <br /> G. SEWER PIPE RISER NOTED ON PLANS AT END OF RUN qTF OF CA0F�� <br /> G 7. TRAP PRIMER CONNECTION G <br /> 2FLOOR ORS I i�ETA�I 3 CLEANOUT TO GRADE DETAILr4`� TRAP PRIMER DETAILr5_`� VENT THRU ROOF DETAIL Consultants <br /> P0.2 SCALE: NONE <br /> P0.2 SCALE: NONE P0.2 SCALE: NONE P0.2 SCALE: NONE <br /> CONDENSATE DRAIN <br /> W <br /> . . n <br /> H THERMOMETER 1�T CAST IRON DOME (TYP.) H J p <br /> (0° - 150 °) COLD WATER INLET T OVERFLOW DRAIN O <br /> m ROOF DRAIN O a <br /> ROOF/FLASHING 1 <br /> CHECK VALVE 4, 21' <br /> o+1 > <br /> 2 ET-I t ET-2, EXPANSION TANK 0 <br /> UNION, TYP. SECURE TO WALL WITH 16 gauge x 2" WIDE ROOF DECK <br /> 0OLTED 0 <br /> 0 TOSOLID LV. EBLOCK NG WITH ET METAL E%4'*4'R SDAP S (TYP) <br /> I TSP RELIEF VALVE INCLUDED WITH TANK, I <br /> DICHARGE TO EXTERIOR 2 BOLTS PER STRAP. <br /> - ' <br /> @ 6" A.F.G. WITH NO LIFTS. LOCATE (1) STRAP WITHIN UPPER 1/3 <br /> Q Cn <br /> � OF WATER HEATER, LOCATE OTHER STRAP ND-HUB OUTLET, SEE I <br /> WITHIN LOWER 1/3 OF WATER HEATER. SEE PLANS FOR SIZE. TYP. W <br /> LL WALL (TYP. OF EACH HEATER) <br /> a <br /> Q o (3 )-%4110 x 2%2" SDS EACH STUD TO W <br /> 0 3/q" DRAIN. DAYLIGHT TO EXTERIOR IN AN APPROVED MANNER 44 BLOCKING' TYP. PARAPET 06 U <br /> QEWH 22 GA. GALV. SM PAN MIN. 3/4' DEEP. ROOF DECK W <br /> SOLDER SEAMS t APPLY C/) <br /> LAV/SINK SECURE PLYWOOD PLATFORM I/2 RUST RESISTANT PAINT J ( D <br /> ---------- <br /> `n TO BLOCKING EDGE t WEDGES oo J JT' W <br /> ^� W/#10 WOOD SCREWS @ 12"O.C. (3) %4'* " SDS OR (3) #12 TEKS O O u) <br /> N <br /> 3/" CONDENSATE UP IN WALL ' TNRU 2x4 PLATFORM a O <br /> q TOP OF PLATFORM FRAMING INTO 4x4 WALL J <br /> r �� BLOCKING @ 12" O.C. W LL r C Q <br /> ~ Oco 0 W <br /> m �'/ ______ _______\ OVERFLOW TO DAYLIGHT SEE PLANS FOR > Z co 0 <br /> 2x4 BLOCKING WEDGES CONTINUATION $ DETAIL 13/AD.2of <br /> PROVIDE VACUUM BREAKER AT a W a' <br /> SANITARY WYE 3/q" PLYWOOD PLATFORM NO-NUB COUPLING, TYP. Z Q Z <br /> EACH WATER HEATER HOSE BIBB DRAIN. <br /> (3)-16d EACH END OF MIN. SUPPORT OF VERTICAL I I Z U Z) <br /> 3/q" FLEXIBLE CONNECTION 4x4 BLOCKING FRONT EDGE NO-NUB PIPE SUPPORT AT bJ W cn Z <br /> E 4x4 INTO 2x4 BLOCKING CAST IRON NO-NUB PIPE, Q U U <br /> BASE AND EVERY FLOOR. I �� �� m <br /> a K VERTICAL SUPPORT SPACING MIN. SLOPE /q PER I -0 K 'J W W <br /> TRAP NOTES: SHALL NOT EXCEED 15'-0". UNLESS OTHERWISE NOTED W V o Z Z <br /> INSULATION, INTERIOR Z ID Q Q J <br /> I. UNLESS OTHERWISE NOTED, ALL VALVES t FITTINGS SHALL BE LINE SIZE. USE HORIZONTAL RWL ONLY Z i a <br /> BELL REDUCERS WHERE REDUCERS ARE REQUIRED <br /> L <br /> FLOOR 2. PROVIDE AND INSTALL A THERMAL EXPANSION TANK ON THE WATER Project Number 1838 <br /> HEATER INLET, PER THE CALIFORNIA PLUMBING , Date JUNE 2019 <br /> "U CODE. TANK TO BE SIZED IN ACCORDANCE WITH THE MANUFACTURERS INSTALL COMBINATION ROOK/OVERFLOW DRAIN PER MANUFACTURERS INSTRUCTIONS. <br /> RECOMMENDATIONS. SEE DETAIL 10 t II/AD.2 FOR ARCHITECTURAL FINISHES Drawn by DW <br /> Checked by AL <br /> z L6 CONDENSATE TAILPIECE DETAIL 7 ELECTRIC AATER HEATER DETAIL rB ROOF DRAIN DETAIL <br /> P0.2 SCALE: NONE P0.2 SCALE: NONE P0.2 SCALE: NONE P01 <br /> N Plot Date &Time <br /> 0 <br /> rn <br /> 15 14 1 13 1 12 1 11 1 10 1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 <br /> 0 <br /> N <br />