Laserfiche WebLink
15 14 113 112 111 110 9 18 17 16 15 14 13 12 1 <br /> A A <br /> TYPICAL PIPE CLAMP REFER TO DETAIL 7.AD.2 FOR SPACING AND FINISHES - TYPICAL <br /> ® CONDENSATE PIPE, SEE PLANS FOR SIZE B-LINE C-PORT SET IN <br /> SINGLE-PLY ROOFING UNISTRUT - STRAP TO <br /> ADHESIVE ALLOW MOVEMENT OF PIPE <br /> B GAS PIPE B <br /> SLIP OR THR'D EXTERIOR APPROVED TYPE 24 GA. G.I. CAP f CLEAT <br /> CAP FOR C.O. FLEXIBLE METAL HOSE 4 <br /> B-LINE C-PORT, SET IN SINGLE PLY ? SINGLE PLY ROOF MEMBRANE <br /> 4 <br /> q0° ELBOW TURNED DOWN VENT GAS COCK ROOFING ADHESIVE <br /> SEE DETAIL 3/AD.2 FOR SPACING <br /> t SPILL AT ROOF RECEPTOR }-HVAC UNIT NATURAL GAS SUPPLY 6 <br /> PROVIDE MIN. I" AIRBREAK TYPE "L" COPPER (DRAW-THRU) <br /> (MIN. I% SLOPE) Yff I zzz zzz <br /> SINGLE-PLY ROOF SYSTEM PER DETAIL 3/AD.2OIOIOIEE— a rc h i tects <br /> C c TIMOTHY P. HUFF & <br /> LJ 6" LONG DIRT LEG <br /> MIN. 3" HVAC UNIT CURB a 6 ASSOCIATES, INC. <br /> Timothy P. Huff, AIA Architect <br /> PIPE SUPPORT LONG RADIUS SIZE AS NOTED95354 <br /> PER DETAIL 4/PO.2 ELBOWS ON PLANS ROOF DECK MATERIAL h: (McHenry Ave., Modesto, )5 1-193 <br /> ( Ph: (209)571-2232 Fax: (209)571-1936 <br /> THICKNESS VARY) <br /> �5�o ARcti <br /> P <br /> NOTE: CONTRACTOR SHALL VERIFY CONDENSATE TRAP SIZING C� o�N� A�< ti <br /> $ DEPTHS WITH MANUF. PRINTED INSTALLATION INSTRUCTIONS ; �� GT�-A <br /> T <br /> D D * No. C 15527 <br /> ASC UNIT CON�EN5A�TE 4 6A5 PIPING �ETA�I Lr2 �'� ROOr- PIPE SUPPORT DETAIL 3 R00P GABS P I P I NIS SUPPORT DETAIL N� REN. 5/21 <br /> ��`� �\�oe� <br /> P0.3 SCALE: NONE P0•3 SCALE: NONE P0•3 of SCALE: NONE CA <br /> Copyright 2019-Timothy P. Huff&Associates <br /> E DRAIN PIPE STEEL4 BRASS PIPE HANGER SCHEDULE COPPER TUBE 4 PIPE HANGER SCHEDULE BCH 40 PVC 4 ABS PIPE HANGER SCHEDULE E ne�Xius <br /> DOME STRAINER I" MIN. AIR GAP HORIZONTAL SUPPORT HORIZONTAL SUPPORT HORIZONTAL SUPPORT <br /> GRATE PIPE YV THREADED OR YeLDED JOINTS SOLVER OR BRAZED JOINTS SOLVENT CEMENTED JOINTS engineering <br /> FINISH FLOOR VENEER <br /> 6 <br /> PIPE SIZE HANGER ROD MAX HORIZONTAL SPAN PIPE SIZE HANGER ROD MAX HORIZONTAL SPAN PIPE SIZE HANGER ROD MAX HORIZONTAL SPAN <br /> Consulting Mechanical Engineers <br /> 1/2" - 3/4" 3/S" 10' 1/2" - 1-1/2" 3/S" ' 1/2" - 1-1/2" 3/S" 4' 1400 Lone Palm Ave,Suite A <br /> 1" - 4" 3/8" 12' 2" - 4" 3/S" 10' 2" - 4" 3/S" 4' Modesto,CA 95351 <br /> Tel:209.572.7399 Fax:209.236.1579 <br /> 6" I/2" 1 12' 1 1 6" I/2" 1 10' 1 1 6" 1 I/2" 1 4' <br /> www.nexusengineering.net <br /> 4" BRASS DRAIN GRATE STEEL PIPE FOR WATER OR DWV THREADED OR WELDED JOINTS, COPPER TUBE AND PIPE WITH SOLDER, BRAZED OR WELDED JOINTS, COPPER TUBE AND PIPE WITH SOLDER, BRAZED OR WELDED JOINTS, HVAC.Plumbing/Piping.Fire Sprinklers <br /> SIZES DEVELOPED FROM TABLE 313.3 $ TABLE 313.6 OF THE 2016 CPC. SIZES DEVELOPED FROM TABLE 313.3 $ TABLE 313.6 OF THE 2016 CPC. SIZES DEVELOPED FROM TABLE 313.3 $ TABLE 313.6 OF THE 2016 CPC. Process/Plant Engineering .Refrigeration <br /> F ALL PIPE SHALL BE SUPPORTED WITHIN IS" OF A JOINT. ALL PIPE SHALL BE SUPPORTED WITHIN IS" OF A JOINT. ALL PIPE SHALL BE SUPPORTED WITHIN 18" OF A JOINT. F <br /> 2" DRAIN PIPE SEISMIC BRACING REQUIRED FOR: SEISMIC BRACING REQUIRED FOR: SEISMIC BRACING REQUIRED FOR: <br /> I. MEDICAL GAS, VACUUM PIPE, COMPRESSED AIR, FUEL PIPING, AND I. MEDICAL GAS, VACUUM PIPE, COMPRESSED AIR, FUEL PIPING, AND I. MEDICAL GAS, VACUUM PIPE, COMPRESSED AIR, FUEL PIPING, AND QROFESS/ON <br /> FLOOR SINK OTHER HAZARDOUS PIPE I" DIA AND LARGER OTHER HAZARDOUS PIPE I" DIA AND LARGER OTHER HAZARDOUS PIPE I" DIA AND LARGER y q� <br /> CONCRETE SLAB 2. ALL PIPING 1-1/4" DIA AND LARGER IN BOILER ROOMS, MECHANICAL 2. ALL PIPING 1-1/4" DIA AND LARGER IN BOILER ROOMS, MECHANICAL 2. ALL PIPING 1-1/4" DIA AND LARGER IN BOILER ROOMS, MECHANICAL -0- <br /> EQUIPMENT ROOMS, t REFRIGERATION MECHANICAL ROOMS EQUIPMENT ROOMS, t REFRIGERATION MECHANICAL ROOMS EQUIPMENT ROOMS, t REFRIGERATION MECHANICAL ROOMS <br /> NO-HUB COUPLING (TYP) 0 3 9 20 <br /> �FOHAN10 ��\P <br /> BARE METAL DECK F0 <br /> G OQ OOQ TYP G OF CAOF <br /> D O Z5 ui i <br /> COMPACTED SUBGRADE 24" ABS WASTE PIPE Consultants <br /> DRAIN ROCK 00 OaO� SEE PLANS FOR CONT. <br /> FILTER FABRIC <br /> 4"0 PVC DRAIN PIPE <br /> O P-TRAP ��- <br /> 0 <br /> 4" '% <br /> HH� 12" J O� = � <br /> SEE UPPER ATTACHMENTS (THIS DETAIL) = O0 <br /> i� <br /> 4 R /I ELL DETAIL 5 fL00R BINK is ETA I L _ = I ORR S" CHANNEL (UNISTRUT O a. <br /> SIMILAR), SPAN 3 FLUTESSMIN. <br /> ro r <br /> Q <br /> o P0.3 SCALE: NONE PO 3 SCALE: NONE _ _ (2)#10 SHEET METAL SCREW, MIN 3 FLUTES V <br /> (PROVIDE WASHERS IF SLOTTED <br /> a� <br /> 12" MAX FOR - _ CHANNEL IS USED) U) O <br /> PIPE 2-I/2" DIA. _ = CHANNEL NUT O <br /> o AND LARGER OR = _ <br /> I PROVIDE SEISMIC I <br /> PIPE CLAMP (TYP) BRACING <br /> Cn <br /> �? PIPE SHIELD INSERT <br /> LL HANGER ROD-SEE W <br /> o- SCHED. FOR SIZE Z <br /> 0 <br /> u <br /> PRECAST CONCRETE BOX��WITH �� W � <br /> o LID MARKED GAS ADJUSTABLE BANDI 06 U <br /> Q HANGER - B-LINE <br /> FINISHED GRADE 6300 OR EQUAL W W <br /> Ln J (n <br /> Ln <br /> J = = II J ❑ <br /> s O <br /> 0 1AROUND NNUNPAVED AREAS " " " " a O J <br /> �, GAS COCK u u Z ^ 2 <br /> � W r ❑ � C <br /> m <br /> > H Q co ❑ W <br /> WROUGHT STEEL Z O co w Q <br /> CLEVIS HANGER - SEE Q Uj M L <br /> PRECAST CONCRETE BQX WITI� I Z Q Z <br /> B' WASHER $ NUT (TYP) 1-5/S" CHANNEL B-LINE 83100 OR EQUAL = W � Q Q Z <br /> LID MARKED WATER <br /> E <br /> K FINISHED GRADE K ' j Q W W m <br /> W Z <br /> M C) Z z <br /> QQ <br /> _ <br /> CY) IS" X IS" MIN. CONCRETE ALL 5U I LD I N6 H ONL I Z a <br /> AROUND IN UNPAVED AREAS BALL VALVE I <br /> PIPE HAN6ER DETAIL Project Number 1838 <br /> P0.3 SCALE: NONE Date JUNE 2019 <br /> LU <br /> Drawn by DW <br /> Checked by AL <br /> z L SHUT-Or-r- VALVE I N 15OX DETAIL I L L <br /> P03 <br /> SCALE: NONE <br /> N Plot Date &Time <br /> 0 <br /> rn <br /> 15 1 14 1 13 1 12 1 11 1 10 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 <br /> 0 <br /> N <br />