Laserfiche WebLink
FAXTELSHEET: <br />DRAWN BY: <br />CHECKED BY: <br />DOCUMENT DATE: <br />ISSUE BLOCKCONSULTANTSSTIPULATION FOR REUSEJOB NUMBER:STORE NO:THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT:CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW.PROTO: <br />ARCHITECT OF RECORD: <br />8131 METCALF AVENUE <br />SUITE 300 <br />OVERLAND PARK, KS 66204 <br />www.brrarch.com <br />TEL: 913-262-9095 <br />FAX: 913-262-9044 <br />WWW.HENDERSONENGINEERS.COMR3 <br />REFRIGERATION <br />SCHEDULES 2080622025TRACY, CA06/24/2006/24/202025-248MAP <br />04/24/2004/24/20TRACY, CA3010 W GRANT LINE RDMARIAH B. MEYER <br />TREVOR G. JONES20806220258345 LENEXA DRIVE, SUITE 300LENEXA, KS 66214913.742.5000 913.742.5001 <br />TGJ <br />3.)Contractor to verify information against latest submittals available at time cases/coils are delivered. <br />2.)Temperature control via pressure controller inside the remote condensing unit. <br />1.)Information included in this schedule is taken from manufacturer's submittals. <br />RCU2 OGP RL HUSSMANN CORPORATION RD3033.145-A - 2/9/2017 -12 -12 -- EL 1 0 45 60 0 <br />RCU1 OGP IDD5SU HUSSMANN CORPORATION RD3032.045-A - 2/9/2017 37 37 -- OT 1 0 40 0 <br />CIRCUIT # APPLICATION MODEL NUMBER MFR EQUIP. NUMBER MANUFACTURER'S <br />TARGET (°F) <br />OWNER'S <br />OPERATING <br />SETPOINT (°F) <br />DUAL TEMP <br />TARGET (°F)DEFROST TYPE FREQUENCY PER <br />DAY <br />PUMP OUT TIME <br />(MIN) <br />MAX DURATION <br />(MIN) <br />TERMINATION <br />TEMP (°F)DRIP TIME (MIN) <br />SETTING FOR WALK-IN BOXES <br />RETURN AIR TEMP DEFROST <br />SETTING FOR CASES/ <br />DISCHARGE AIR TEMP <br />SYSTEM RCU DISCHARGE AIR TEMPERATURE AND DEFROST PARAMETERS <br />7.)Existing IDDF5SU case converted from self-contained to RCU-fed. <br />6.)Existing RFL case converted from self-contained to RCU-fed. <br />5.)OEM to ensure adequate size of compressors and condenser to meet 105% NRE at the scheduled ambient temperature conditions above. <br />4.)Furnish RCU(s) with oversized receiver. <br />3.)Furnish with thermostats and solenoid valves for temperature control. <br />2.)Furnish with time clock for defrost control, installed inside condensing unit. <br />1.)Owner's designated refrigeration equipment manufacturer: HUSSMANN. <br />General Notes: <br />SUCTION GROUP #2 REQUIRED CAPACITY (MBH):7.74 -22 <br />(°F) Suction Temperature <br />RCU2.2 4 DRS 1 RFL HUSSMANN CORPORATION <br />OGP 4.4 -- -19 -12 E3S130 EL 13.5 208/1 1.2 120/1 -- 4.7 <br />SEE NOTE 6.RCU2.2 <br />RCU2.1 <br />3 DRS <br />1 RFL HUSSMANN CORPORATION <br />OGP <br />3.3 -- -19 -12 E3S130 EL 10.1 208/1 0.9 120/1 -- 3.5 <br />ADDITIONAL ELEC LOAD = CONDENSATE PUMP. <br />CONDENSATE PUMP, DRAIN PAN, ANTI-SWEAT AND FANS SHARE CIRCUIT. EVAP FANS AND <br />DRAIN PAN RUN ALTERNATELY. <br />RD3033.145-A - 2/9/2017 <br />RCU2.1 <br />RCU2 MAIN CIRCUIT - SUBCIRCUITS ARE BELOW HUSSMANN CORPORATION OGP TOTAL MAIN CIRCUIT 7.7 -19 -12 EL 23.5 208/1 2.1 120/1 -- 8.1 <br />CIRCUIT LOAD AND ELECTRICAL ARE TOTALS OF SUBCIRCUITS RD3033.145-A - 2/9/2017 RCU2 <br />SUCTION GROUP #1 REQUIRED CAPACITY (MBH):8.48 31 <br />(°F) Suction Temperature <br />RCU1.3 <br />12 FT <br />1 IDD5SU HUSSMANN CORPORATION <br />OGP <br />3.2 -- 33 37 E3S130 OT -- -- 1.0 120/1 -- -- <br />ADDITIONAL ELEC LOAD = CONDENSATE PUMP. <br />CONDENSATE PUMP AND FANS SHARE CIRCUIT.RD3032.045-A - 2/9/2017 <br />RCU1.3 <br />RCU1.2 12 FT 1 IDD5SU HUSSMANN CORPORATION <br />OGP 3.2 -- 33 37 E3S130 OT -- -- 1.0 120/1 -- -- <br />SEE NOTE 7.RCU1.2 <br />RCU1.1 8 FT 1 IDD5SU HUSSMANN CORPORATION <br />OGP 2.0 -- 33 37 E3S130 OT -- -- 0.6 120/1 -- -- <br />SEE NOTE 7.RCU1.1 <br />RCU1 MAIN CIRCUIT - SUBCIRCUITS ARE BELOW HUSSMANN CORPORATION OGP TOTAL MAIN CIRCUIT 8.5 33 37 OT -- -- 2.6 120/1 -- -- <br />CIRCUIT LOAD AND ELECTRICAL ARE TOTALS OF SUBCIRCUITS RD3032.045-A - 2/9/2017 RCU1 <br />CKT #FT /# of Doors 2 Dr/4' 3 Dr/6' 4 Dr/8' 5 Dr/12' L W H <br />Case/Coil Model Case/Coil Manuf.Application WI Evaps Distributor Nozzle (MBH) Load (MBH) <br />SST Air Temp EPR LLSV Type Amps Voltage Amps Voltage (120v) (120v)Comments Equip Number CKT # <br />& Model #Coil TXV / Sub-Circuit Load Circuit Evap Walk-In Circuit Control Valves Defrost Defrost Heaters Fans Amps Amps <br />Case Fixture Length / Quantity Walk-In Box Size LSHX Y or N?Evaporator Case/Lights Anti-Sweat <br />CIRCUIT INFORMATION FIXTURE ELECTRICAL INFORMATION <br />Date Prepared: -- Design DB (°F) / WB (°F): 109°F / 79°F Interior Design DB (°F) / RH%: 75°F / 50% Fixture and Field Piping (lbs): N/A Sys. Pilot Elec: 208V 1 Ph Cond. Elec. 208/220V 3 Ph 60Hz Est. Winter THR Avail (MBH): N/A ASHRAE Design Conditions Weather Station: STOCKTON METROPOLITAN, CA, USA <br />Proto Cycle Date: 1/1/2020 Elevation (ft): 26 Prepared By: MARK PFLUGHOEFT Rack & Cond. Charge (lbs): N/A Defrost Elec: 208V 60Hz 1 or 3 Ph Est. Summer THR (MBH): N/A Evap. Superheat (°F): 10 0.4% Monthly Max WB from ASHRAE Pub. 2017 <br />Proto Size: Special Project City/State: TRACY, CA Consultant: HEI Estimated Refrigerant Charge (lbs): N/A System Elec: 208/220V 3ph 60Hz Cond. Design TD (°F): 15 Heat Reclaim Water (GPM): --EXTERIOR WET BULB (WB) (°F): 79.2 <br />Format: Supercenter Store #: 2025 System Type: Condensing Unit Refrigerant: R407A Refrig. EMS: NOVAR Sat. Cond. Temp (°F): 124 Heat Reclaim Use: N/A SG1 Comp RGT (°F): 50 SG2 Comp RGT (°F): 30 SG3 Comp RGT (°F): N/A 5 yr. Extreme DB from ASHRAE Pub. 2017 <br />REFRIGERATION SCHEDULE SYSTEM RCU Refrig. OEM: HUSSMANN Condenser Type: Air Heat Reclaim Media: N/A <br />SG1 Refrig. Liquid <br />Temp (°F):117 <br />SG2 Refrig. Liquid <br />Temp (°F):117 <br />SG3 Refrig. Liquid <br />Temp (°F):N/A EXTERIOR DRY BULB (DB) (°F): 108.7 <br />ADD SHEET TO SET <br />1 <br />1 07/17/20 CCD#1