Laserfiche WebLink
REVISIONS <br /> NO. DESCRIPTION DATE <br /> VENT DISCHARGE <br /> A MINIMUM OF 48" <br /> ABOVE THE ROOF OR <br /> 48"ABOVE ANY PARAPET <br /> OR FRESH AIR INTAKE <br /> WITHIN 10 FEET AT SIM. EQUIPMENT SUPPORT POST, RE: S3 <br /> FIELD SEAM CONT. BEAD OF SEALANT <br /> STAINLESS STEEL CLAMPING <br /> RING <br /> JOINT COVER SINGLE PLY BONDING <br /> CENTER ON ADHESIVE, RE: SPECS. <br /> VTR/CONDUIT/PIPE PLAN VIEW INTERSECTION MFR. PREFABRICATED SPLIT PIPE <br /> AS OCCURS <br /> BOOT <br /> PROVIDE GAS VENT: TYPE B' <br /> NONCOMBUSTIBLE UL APPROVED FOR SEAM PLATE W/FASTENERS <br /> SEALANT AT SIM. 1" CLEARANCE FROM SPACED @ 12" O.C. MAX. CONT. CUT EDGE <br /> COMBUSTIBLES AT SIM. SEALANT PER MFR., <br /> SEALANT SINGLE PLY MEMBRANE, RE: SPECS. <br /> PROVIDE A 3/4" GOOSENECK RE: SPECS. <br /> ARCH. PROJECT NO. <br /> STAINLESS FOR THE LOTTERY CABLING _ <br /> STEEL CONDUIT LOCATION. CAP END O° HOT AIR WELD 2006 <br /> CLAMPING W/REMOVABLE CAP 2'-0" 2'-0" DRAWN <br /> RING <br /> PRE-MOLDED PIPE BOOT - - - - - - - - - - - - - - - - - - - - � L - - - - - - - - - - - - - - - - - - - - - - D.M. <br /> CHECKED <br /> SEAM PLATE W/ C P <br /> FASTENERS 4 PER <br /> PENETRATION SUBMITTAL DATES <br /> HOT AIR WELD 03/12/20 <br /> JOINT COVER REQUIRED AT <br /> FIELD SEAM, SEE PLAN VIEW PATCH BACK INSULATION TO <br /> MATCH EXISTING ADJACENT OTB DATE <br /> THICKNESS AND SLOPE, RE: SPECS <br /> (E) ROOF DECK <br /> (E)INSULATION <br /> (E) ROOF FRAMING x <br /> (E)ROOF DECK 3 o F <br /> oo�600 <br /> Ua W wp°, <br /> ROOF PENETRATION EQUIPMENT SUPPORT FLASHING <br /> o [t4� a <br /> 45 <br /> 1 1/2" = 1'-011 1 1/2" = 1'-0" z <br /> z <br /> zW �oAoo �'� <br /> �OW E" � wF•' �O <br /> 3 z �u uw cu. <br /> Q uwozaz <br /> �¢ <br /> � ' . o <br /> CA <br /> gu o <br /> 3/4" EXT. CD PLYWOOD W/24 <br /> GA. GALV. METAL FLASHING GALVANIZED METAL FLASHING r <br /> OVER ENTIRE TOP @ M Lc� <br /> PLATFORM @ SIM. CONDITION VENTED CURB W 0 <br /> EXTENSION <br /> 1"xl 1/2"xl/8" Q <br /> MECHANICAL DUCT THRU SKYLIGHT & FRAME, RE: SPECS. PRESSURE TREATED o <br /> ROOF WHERE OCCURS ANGLE , - TWO LAYERS OF co m <br /> RIGID FOAM INSULATION WOOD NAILER 0 <br /> NEW GALVANIZED METAL "FIREMASTER" 00 <br /> DUCT WRAP,RE: M1 7 - PREFABRICATED o <br /> SINGLE PLY MEMBRANE, FLASHING OVER EXISTING MFRS / AIR SEAL TAPE (BY MFR.) METAL CURB, RE: SPECS. O u _ O CN <br /> RE: SPECS. WOOD NAILER. STANDARD Q <br /> MECHANICAL DUCT I I SKYLIGHT FASTENERS @ 24" O.C. r - - - - - L - - - - - - <br /> THRU ROOF WHERE SAFTEY 1 1/4" GALVANIZED TPO SINGLE PLY \ <br /> 1 1/2" GALVANIZED ROOF TPO SINGLE PLY BONDING 1 1/2 GALVANIZED ROOF OCCURS SCREEN, RE: PREFABRICATED METAL CURB, ROOF NAILS @ 12" O.C. �J �� MEMBRANE, RE: SPECS. y w <br /> NAILS @ 12" O.C. ADHESIVE,RE: SPECS. NAILS @ 12 O.C. SPEC. \ / ' w \ <br /> ROOF TOP UNIT ROOF TOP UNIT NEW FELT BACKED SECTION RE: SPECS. TOP OF CURB TO BE O 0 w Z <br /> SINGLE PLY MEMBRANE, RE: O SINGLE PLY BONDING a W <br /> PRESSURE SEAM PLATE W/FASTENERS SINGLE PLY MEMBRANE 077200 <br /> SPACED 12" O.C. MAX. EXISTING WOOD - _ � � � SINGLE PLY BONDING � � � 0 � � � <br /> i L Q <br /> @ NAILER TO BE RE- OVER EXISTING FASTENERS ADHESIVE, RE: SPECS. SEAM PLATE W/FASTENERS <br /> TREATED WOOD MEMBRANE RE: SPECS. PATCH BACK INSULATION TO W Q <br /> USED. v� 24" O.C. SEAM PLATE W/FASTENERS EXHAUST SPACED @ 12 O.C. MAX. z <br /> NAILER CG MATCH EXISTING ADJACENT r r - <br /> CONT. CUT EDGE SEALANT w H <br /> w � \ / SPACED 12 O.C. <br /> O PER MFR., RE: SPECS O SINGLE PLY BONDING @ THICKNESS AND SLOPE, RE: CONT. CUT EDGE SEALANT W <br /> PREFABRICATED v� `f' H ADHESIVE, RE: SPECS. CONT. CUT EDGE SEALANT SPECS 6" 6" PER MFR., RE: SPECS T <br /> METAL CURB, RE: - x x 2'_ 0" PER MFR., RE: SPECS = Z d o <br /> HOT AIR WELD SEAM PLATE W/ _ N MIN. MIN. N <br /> M1 &M2. FASTENERS SPACED 12" - 2 0 HOT AIR WE JL o <br /> 21-011 - 2'-0" - @ (E)INSULATION o <br /> N PREFABRICATED `� O.C. MAX.VELD 2'-0" 2'-0" w <br /> METAL CURB TO BE - HOT AIR WELD Q <br /> RE-USED. PROTECT v _ <br /> U CONT. CUT EDGE w <br /> DURING RE-ROOF SEALANT PER MFR., RE: <br /> ACTIVITIES. SPECS <br /> I I I I <br /> EXISTING INSULATION <br /> EXISTING ROOF DECK � ����� <br /> (E)ROOF DECK � (E) ROOF DECK <br /> PATCH BACK INSULATION TO SUPPORT FRAMING OR STEEL PATCH BACK INSULATION TO SUPPORT FRAMING, (E)ROOF DECK, RE: S3 (E)ROOF DECK C,37 9 X <br /> 01/31/21 <br /> MATCH EXISTING ADJACENT FOR REINFORCING AT � _���� � <br /> MATCH EXISTING ADJACENT DECK REINFORCING AS RE: S3 & 53.1-1 SUPPORT FRAMING OR STEEL �' <br /> THICKNESS AND SLOPE, RE: SPECS OCCURS,RE: S3.1-2 &3 THICKNESS AND SLOPE, RE: SPECS OPENING DECK REINFORCING AS 4 <br /> OCCURS,RE: S3.1-2 &3 A <br /> PREFABRICATED CURBED OPENING EXISTING PREFABRICATED CURB SKYLIGHT & CURBED OPENING EXHAUST DUCT W/ ONE HOUR WRAP <br /> 6 11/2" F-0" 7 1 1/2" F-0" 8 11/2" F-0" 9 11/2" F-0" <br /> O <br /> I I <br /> SEAM PLATES & <br /> FASTENERS PER O <br /> I I <br /> NOTE: WALKWAY PADS SHALL BE MFR'S.RECOMMENDATIONS, rTl <br /> SPACED 1"MIN. 3"MAX. APART IN ALL RE: SPECS <br /> DIRECTIONS TO ALLOW FOR O <br /> DRAINAGE I <br /> FACE OF CURB O �I <br /> TPO SINGLE PLY M--1 <br /> MEMBRANE, RE: SPECS MM <br /> SINGLE PLY BONDINGHOT AIR WELD <br /> W <br /> ADHESIVE, RE: SPECS <br /> I I <br /> SEAM PLATE W/FASTENERS <br /> I <br /> SPACED @12" O.C. - - L - - I - - - L - - - - - - - - - - - - O <br /> HOT AIR WELD O <br /> 1 WALKWAY PAD, HOT WELD CRISS-CROSS HALF O <br /> ALL FOUR SIDES SHEETS AT PERIMETER O <br /> &CORNERS FOR <br /> ADDITIONAL O <br /> REINFORCEMENT <br /> (E)INSULATION <br /> (E)ROOF DECK \ \ <br /> 'I 'I <br /> CONT. CUT EDGE SEALANT <br /> PER MFR.,RE: SPECS <br /> 1 o WALKWAY PAD WALL OR CURBS l l PERIMETER SECUREMENT LAYOUT <br /> U 1 1/2" = 1'-0" 1/4" = 1'-0" <br /> �I <br /> U <br /> z <br /> 0 <br /> U <br /> O <br /> H <br /> o (E) WOOD NAILER <br /> 0 <br /> u (N) 24 GA. METAL FLASHING <br /> (N) FASTENERS W/NEOPRENE <br /> WASHERS @ 12" O.C. <br /> a� <br /> p�p HGCIui <br /> R� <br /> O (E) EQUIP. CURB <br /> U <br /> g SHEET TITLE <br /> a� <br /> Nwo,::�t <br /> U <br /> (E) INSULATION <br /> ROOF DETAILS <br /> (E) ROOF DECK <br /> (E) ROOF JOIST <br /> a <br /> N <br /> 7; SHEET <br /> 0 <br /> 0 <br /> FLASHING E EQUIPMENT CURB <br /> 19 N <br /> N 1 1/2" F-0" <br /> A7 ,01 <br />