My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS (2)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4600
>
3600 - Recreational Health Program
>
PR0360045
>
WORK PLANS (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2020 4:52:57 PM
Creation date
9/24/2020 3:19:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
WORK PLANS
RECORD_ID
PR0360045
PE
3616
FACILITY_ID
FA0002104
FACILITY_NAME
SUSD-FRANKLIN HIGH SCHOOL
STREET_NUMBER
4600
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14331006
CURRENT_STATUS
01
SITE_LOCATION
4600 FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> - - LL � `o1. <br /> I � <br /> I I 1 <br /> o <br /> I <br /> / o <br /> / <br /> / <br /> / <br /> ° O <br /> o <br /> / <br /> ❑ ° x <br /> VERDE DESIGN <br /> ❑ ° / <br /> / ° U LANDSCAPE ARCHITECTURE <br /> / / \ CIVIL ENGINEERING <br /> / SPORT PLANNING& DESIGN <br /> / ® 1843 Iron Point Rd #140 <br /> \ Folsom,CA 95630 <br /> / \ ° tel: 916.415.6554 <br /> o fax:408.985.7260 <br /> o <br /> WS ix www.VerdeDesignlnc.com <br /> o / 1 <br /> / E2.1 <br /> 0 / J STAMP <br /> 0 r , <br /> IDS1771 <br /> CgpF <br /> o ® In <br /> 0 ° ° <br /> o <br /> No. 4089 <br /> / w n <br /> o LJ o // / c o ° Signature <br /> o II // `` IXPJUL0 <br /> Y 2021 <br /> zP'l <br /> CONSULTANT <br /> Z <br /> O ❑p © FS / C <br /> - - - - - \ (E) 5qG LLd <br /> / o ���5 <br /> --OH_ DE 3 E168 N <br /> � -oH_ L BOX <br /> _ 1 1 <br /> x <br /> Exp. 21 <br /> LL <br /> ♦ I �FCTR�C <br /> .. °H--- off----� \/ o e ° gTFOFCA��F� <br /> --pH---- <br /> Q <br /> W ° ° I� 12 13 I 2 SEIGNAL // \// ° �♦ ° <br /> 0 <br /> O CONDUIT <br /> G <br /> o <br /> Of <br /> a_WLLI � � e <br /> American Consulting Engineers <br /> W ox Electrical nc. <br /> o Lr a Q 8 ® ` 2 ® 1590 The Alameda, Suite 200 408/236-2312 <br /> Q ar ° © 1 ® o \ E2.2 \ San Jose, ca 95126 Fax: 408/236-2316 <br /> N - p50i o / JOB # E19147.00 <br /> a of I / <br /> Of <br /> " <br /> pit <br /> s �. O/Of <br /> / x( <br /> V © ® (N) XFMR <br /> 2 / <br /> o � <br /> ° (N) PANEL "TC"LL] <br /> I <br /> __o_°°°°°°°°°e__________ <br /> \ x <br /> Z T 11 <br /> o �I 5 ' ` \\ ♦♦ <br /> a_ <br /> E1.211 4T <br /> ) <br /> I � x <br /> z q SHEET TITLE <br /> 0 <br /> w . 000000000 0000000000 0000000000 00�� 0000 ♦ �° \ <br /> z . 000000000 . 000000000 0000000000 0000 000 <br /> 0 0000000000 0000000000 0000000000 000 oo o <br /> 0000000000 . 000000000 0000000000 000000 ��00 4 �0 ELECTRICAL <br /> Z . 0000000 0000000000 0000000000 0000000 r <br /> 00 o x <br /> z o ° 5 11 0 NEW SITE PLAN <br /> o ° o <br /> w <br /> o \ b <br /> 0 0 ` E4.1 x <br /> uj PROJECT NAME <br /> >Li <br /> 5 5 o X <br /> 0 11 4 4 ♦♦ <br /> CC <br /> Q E' ) ° o X FRANKLIN HIGH SCHOOL <br /> � 4 I <br /> ATHLETIC IMPROVEMENTS <br /> s� <br /> ��� W� <br /> W o <br /> o0 0 o 0 <br /> Of <br /> 0 0 0 0 0 0 o O O o 0 0 0 0 0 0 0 <br /> - - - - - - _ - - - o 0 0 0 0 <br /> z T `E Y ) \ ) n I A Of <br /> PROJECT ADDRESS <br /> Q <br /> 4600 E. FREMONT ST. <br /> z ELECTRICAL NEW SITE PLAN STOCKTON, CA 95215 <br /> 0 <br /> w <br /> E 1 .1 50ALE: 1" = 40'-0" <br /> 0 <br /> SUBMITTAL DATE <br /> NORTH <br /> o <br /> DD/50% SUBMITTAL 03/06/2020 <br /> Of <br /> GENERAL NOTES: SHEETS NOTESi CONDUIT SCHEDULE <br /> (L <br /> w <br /> DSA 100% SUBMITTAL 05/01/2020 <br /> z <br /> z <br /> m 1. CONTRACTOR SHALL COORDINATE UNDERGROUND REQUIREMENTS WITH ALL 11. CONTRACTOR SHALL COORDINATE FINAL LOCATION OF ALL IN-GRADE PULL L LOCATE AND INTERCEPT (E) (2) 4"C WITH NEW POWER PULL BOX. EXTEND POWER SYSTEMS COMMUNICATION SYSTEMS <br /> o OTHER TRADES TO AVOID CONFLICT. BOX WITH LAND50APE ARCHITECT. THE INTENT 15 TO VOID RELOCATING CONDUITS TO NEW SWITCHBOARD. <br /> w PULL BOXES. I (N) (2) 4"C - MAIN 5WITCHBOARD 10 (N) (4) 4"GO - DATA <br /> 2. CONTRACTOR TO SITE SURVEY EXISTING CONDITIONS AND LOCATIONS OF L2 UTILIZE (E) 4" 51GNAL CONDUIT TO RUN NEW FIBER FROM (E) 'MDF' IN MAIN (1) (1) 2"C, - SPARE <br /> W� EXISTING UNDERGROUND SYSTEMS, WHERE (N) TRENGHWORK OCCURS PRIOR 12. ALL POWER SYSTEM CONDUITS STUB IN "ELECTRICAL" PULL BOX AND ALL BUILDING 'A' TO NEW ATHLETIC, FIELD CONCESSION BUILDING. 2 (N) (2) 2"G - POWER - MUSGO. (I) (I) I"GO - SPARE <br /> <Z TO BIDDING. CONTRACTOR SHALL TAKE PROPER PRECAUTIONS TO ENSURE COMMUNICATION SYSTEMS CONDUIT IN "SIGNAL" BOXE5 AS REQUIRED BY <br /> O (E) UNDERGROUND 5Y5TEM5/CONDUIT/PIPE5 ARE NOT DAMAGED DURING CODE. (N) 2"G - POWER - LIGHTING. <br /> 0o INSTALLATION. CONTRACTOR 15 RESPONSIBLE FOR ANY REPAIRS REQUIRED O 5TUB CONDUIT IN (E) SIGNAL BOX. REPLACE IN-GRADE EXTENSION TO (N) TOO - POWER - SPARE. II (2) TOO - SIGNAL - SPARE. NO. REVISIONS DATE <br /> �o IN THE EVENT THE (E) UNDERGROUND SYSTEMS ARE DAMAGED A5 A RESULT 13. ALL IN-GRADE PULL BOXES SHALL BE 82436 UNLE55 OTHERWI5E NOTED. SUCCESSFULLY GROUT/CAULK CONDUIT 5TUB-INS. EXTEND (E) SIGNAL 3 (N) 2"G - POWER - GOLF. Q <br /> OF THE (N) ELECTRICAL TRENCHWORK. CONDUIT FROM (E) 516NAL BOX TO NEW CONCESSION BUILDING. <br /> }> 12 (E) (1) TOO - SIGNAL - DATA <br /> M U-00 3. SEE SINGLE LINE DIAGRAM FOR WIRE SIZES AND CONDUIT REQUIREMENTS. O UTILIZE (E) (2) 4"C TO ROUTE NEW FEEDERS FROM 5UE35TATION #2 TO NEW 4 (N) 1 I/4"C - POWER - RECEPTACLE. (E) (1) TOO - 516NAL - CLOCK, PAGING, INTERCOM, INTRUSION Q <br /> W N SWITCHBOARD. (E) (2) 2"CO - 51GNAL - SPARE <br /> W2 4. CONTRACTOR TO COORDINATE 517E PLAN TO COMBINE ALL UNDERGROUND 5 (N) 2"G - POWER - TENNIS COURT. (E) (I) I"GO - SIGNAL - EMS (SPARE) Q <br /> W a CONDUIT IN COMMON TRENCH AS NECESSARY. <br /> 6 (N) 2"C, - POWER - XFMR- PANEL "TC„ 13 (E) (I) 4"00 - SIGNAL - DATA, TELEPHONE <br /> Of (E) (1) 4"CO - SIGNAL - CLOCK, PAGING, INTERCOM, INTRU51ON <br /> Of Q <br /> 5. ALL EMPTY CONDUIT SHALL BE PROVIDED WITH NYLON PULL CORD A5 (E) (2) 4"GO - SIGNAL - SPARE <br /> a NOTED IN THE SPECIFICATIONS. <br /> (E) (1) TOO - 51 GNAL - SPARE <br /> 00 6. ALL ELECTRICAL WORK SHALL BE INSTALLED PER 2016 NEC. (E) (1) 1"GO - 51GNAL - EM5 (SPARE) <br /> N� <br /> of 7. PRIOR TO ALL (N) TRENCHES, CONTRACTOR TO USA ALL (E) ELECTRICAL <br /> aw CONDUITS AND OTHER UTILITIES TO FAMILIARIZE THEMSELVES WITH THE DRAWN BY CHECKED BY <br /> <QFIELD CONDITIONS AND ADJUST (N) TRENCHES ACCORDINGLY. MG SB/ SF <br /> W W 8 . IN-GRADE PULL BOX IDENTIFIED WITH 'P' SHALL HAVE LID LABELED DATE ISSUED SCALE <br /> o ELECTRICAL'. <br /> Z Of <br /> 05/01 /2020 AS NOTED <br /> Qa cl. IN-GRADE PULL BOX IDENTIFIED WITH '55HALL HAVE LID LABELED '51157NAL'. <br /> ZPROD. NO. <br /> Z w 10. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY 5AW GUTTING AND 1911000-1211 <br /> Fn w REMOVAL OF EXI5TING SURFACES TO FACILITATE UNDERGROUND SYSTEMS. <br /> 0o THE CONTRACTOR SHALL PATCH AND REPAIR ALL DAMAGED AND GUT SHEET NO. <br /> 0 o SURFACES TO MATCH ADJACENT. C • <br /> OF <br /> <0 <br /> DRAWING NAME: \\ACEEDC2\projects\projects\Year 2019\E19147 Franklin HS Additional Athletic Improvement\ATHLETICS (Ball Fields & POOL)\E1.1—Electrical Site Plan NEW.dwg <br /> PLOT DATE: 04-30-20 PLOTTED BY: sbuhay <br />
The URL can be used to link to this page
Your browser does not support the video tag.