My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1991-2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
0
>
4400 - Solid Waste Program
>
PR0515734
>
CORRESPONDENCE_1991-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2025 11:32:48 AM
Creation date
9/25/2020 3:47:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1991-2001
RECORD_ID
PR0515734
PE
4430 - SOLID WASTE CIA SITE
FACILITY_ID
FA0012312
FACILITY_NAME
CITY OF TRACY LANDFILL
STREET_NUMBER
0
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303015
CURRENT_STATUS
Active, billable
SITE_LOCATION
CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Pending
Scanner
SJGOV\cfield
Supplemental fields
Site Address
CORRAL HOLLOW RD TRACY 95376
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
352
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND IkORTING PROGRAM NO. 0 6 <br /> SAN JOAQUIN COUNTY DEPARTMENT OF PUBLIC WORKS <br /> FOR POST-CLOSURE AND CORRECTIVE ACTION MONITORING <br /> CORRAL HOLLOW MUNICIPAL SOLID WASTE LANDFILL <br /> SAN JOQUIN COUNTY <br /> groundwater with respect to the elevations of the top and bottom of the screened <br /> interval and the elevation of the pump intake. Hydrographs of each well shall be <br /> prepared quarterly and submitted annually. <br /> Groundwater samples shall be collected from the point-of-compliance wells, <br /> background wells, and any additional wells added as part of the approved <br /> groundwater monitoring system. Samples shall be collected and analyzed for the <br /> monitoring parameters in accordance with the methods and frequency specified in <br /> Table I. <br /> The monitoring parameters shall also be evaluated each reporting period with <br /> regards to the cation/anion balance, and the results shall be graphically presented <br /> using a Stiff diagram or a Piper graph. Samples for the constituents of concern <br /> specified in Table I shall be collected and analyzed in accordance with the <br /> methods listed in Table V every five years. <br /> 2. Unsaturated Zone Monitoring <br /> The Discharger shall install and operate an unsaturated zone detection monitoring <br /> system that complies with the applicable provisions of§20415 and §20420 of <br /> Title 27 in accordance with a detection monitoring plan approved by the <br /> Executive Officer. The Discharger shall collect,preserve, and transport samples <br /> in accordance with the quality assurance/quality control standards contained in the <br /> approved Sample Collection and Analysis Plan. <br /> Unsaturated zone samples shall be collected from the monitoring devices and <br /> background monitoring devices of the approved unsaturated zone monitoring <br /> system. The collected samples shall be analyzed for the listed constituents in <br /> accordance with the methods and frequency specified in Table H. All monitoring <br /> parameters shall be graphed sous to show historical trends at each monitoring <br /> point. <br /> 3. Surface Water Monitoring <br /> The Discharger shall install and operate a surface water detection monitoring <br /> system where appropriate that complies with the applicable provisions of§20415 <br /> and §20420 of Title 27 and has been approved by the Executive Officer. <br /> For all monitoring points and background monitoring points assigned to surface <br /> water detection monitoring, samples shall be collected and analyzed for the <br /> monitoring parameters in accordance with the methods and frequency specified in <br /> Table III and IV. All surface water monitoring samples shall be collected and <br />
The URL can be used to link to this page
Your browser does not support the video tag.