Laserfiche WebLink
SAN JOAQUIN <br />COUNTY— <br />Environmental <br />OU 1TY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />CRUISERS MANTECA #29 <br />1137 W LATHROP RD, MANTECA <br />August 24, 2020 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR- Notice to Comply) <br />Item # <br />Remarks <br />316 <br />HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br />OBSERVATION: Water was found in the Diesel, 91 and 87 fill sumps, 87 and diesel STP sumps. <br />REGULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the <br />system by precipitation, infiltration, or surface runoff. <br />CORRECTIVE ACTION: The service technician removed approximately one gallon of liquid from the diesel, 91, 87 <br />fill, 87 and diesel STP sumps and returned the sensor to its proper location. Immediately contact a properly <br />licensed, trained, and certified contractor to address the water intrusion into the Diesel, 91 and 87 fill sumps, 87 and <br />diesel STP sumps under permit and inspection of the EHD. <br />This was corrected on site. <br />This is a minor violation. <br />319 <br />CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br />tested. <br />OBSERVATION: The 87 and 91 spill containers failed when tested. <br />REGULATION GUIDANCE: All spill containers shall have a minimum capacity of five gallons and be capable of <br />containing a spill or overfill until it is detected or cleaned up. <br />CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to repair or <br />replace the spill container under permit and inspection of the EHD. <br />This is a minor violation. <br />Overall Inspection Comments: <br />An inspection checklist was provided to the facility operator on the day (08/24/20) of inspection. The EHD has <br />written the complete report on 08/26/2020 which replaces the initial checklist. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 09/25/2020. <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />Documents provided during inspection: Return to compliance certification form and list of approve free CUPA <br />training classes. <br />FA0019793 PR0530093 SCO01 08/24/2020 <br />EHD 23-01 Rev. 8/11/2020 Page 5 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />