My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 3:11:20 PM
Creation date
9/28/2020 9:19:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
FACILITY_NAME
H&S Energy Products,#3034
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK ANNULAR TESTING <br /> Test Method By : • Manufacturer C Industry Standard O Professional Engr, O Other (see below) <br /> Test Method Uses : o Pressure • Vacuum o Hydrostatic o Other ( see below ) <br /> Measuring Equipment Used : Vacuum Gauge ( range 0 to 30 inches Hg ) <br /> Description Tank # 1 Tank #2 Tank #3 <br /> Product stored _ Gasoline - 87 Gasoline - 89 Gasoline - 91 <br /> Tank manufacturer Unknown Unknown Unknown <br /> Tank material Steel Steel Steel <br /> Tank capacity (US gallons) 12 , 000 10 , 000 8 ,000 <br /> Is this a multi-compartment tank? No No No <br /> Dry or Brine filled annular? Dry Dry Dry <br /> Monitoring system show normal annular? Yes Yes Yes <br /> Is water table above tank bottom? Unknown Unknown Unknown <br /> Was sensor removed for testing? Yes Yes Yes <br /> Was sensor properly replaced after testing ? Yes Yes Yes <br /> Wait time for vacuum to stabilize (hr: min) 0 :05 0 :05 0 :05 <br /> Test start time 9 :59 AM 9 :47 AM 9 :39 AM <br /> Initial vacuum (inches Hg) 7.0 7 .0 7 . 0 <br /> Test end time 10 :59 AM 10:47 AM 10:39 AM <br /> Final vacuum (inches Hg) 7.0 7 . 0 7 .0 <br /> Test duration (hr:min ) 1 : 00 1 :00 1 :00 <br /> Change in vacuum (inches Hg) 0 .0 0 . 0 0 .0 <br /> Pass/Fail threshold (inches Hg / hour) 2 .0 2 . 0 2 . 0 <br /> TEST RESULT PASS PASS PASS <br /> Comments : <br /> © 2017 Walton Engineering , Inc. <br />