Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> MAKE / MODEL OF MONITORING SYSTEM : Veeder- Root TLS -350 <br /> CERTIFICATION / TEST DATE : December 06 , 2017 <br /> Al . FACILITY A2 . OWNER <br /> Name Colonial Energy #40134 Name Colonial Energy , LLC . <br /> Address 1434 W. Yosemite Avenue , Manteca , CA 95337 Address 2860 N . Santiago Blvd . 2nd Floor, Orange , CA 92867 <br /> Phone # 916 -285-7402 Phone # 714 -761 -5426 <br /> Contact Station Manager Contact Victor Hassan <br /> A3 . C U P A A4 . TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering , Inc . <br /> Address 1868 E . Hazelton Avenue , Stockton , CA 95202 Address P . O . Box 1025 , W . Sacramento , CA 95691 <br /> Notified November 21 , 2017 Lic # 617238 A , B , Haz <br /> Inspector John/Zuna Contact Veronica Freitas <br /> Phone # 209 -468-3442 Phone # 916 -373-1166 <br /> B . INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced ) <br /> B1 : TANKS <br /> Tank #1 ( Product) : 87 Tank #2 (Product) : 89 <br /> ❑ In -Tank Gauging Probe Model : ❑ In -Tank Gauging Probe Model : <br /> Annular Space or Vault Sensor Model : 0794390420 Annular Space or Vault Sensor Model : 0794390-420 <br /> Piping Sump / Trench Sensor(s) Model : 0794380 -208 Piping Sump I Trench Sensor(s) Model : 0794380 -208 <br /> ❑ Fill Sump Sensor(s) Model : ❑ Fill Sump Sensor(s) Model : <br /> Mechanical Line Leak Detector Model : VMI 99LD -2000 Mechanical Line Leak Detector Model : VMI 99LD-2000 <br /> I <br /> ❑ Electronic Line Leak Detector Model : ❑ Electronic Line Leak Detector Model : <br /> ❑ Tank Overfill / High -Level Sensor Model : ❑ Tank Overfill / High -Level Sensor Model : <br /> ❑ Other (specify equipment in Section E ) Model : ❑ Other (specify equipment in Section E) Model : <br /> Tank #3 ( Product) : 91 Tank #4 (Product) : <br /> ❑ In -Tank Gauging Probe Model : ❑ In -Tank Gauging Probe Model : <br /> 0 Annular Space or Vault Sensor Model : 0794390420 ❑ Annular Space or Vault Sensor Model : <br /> 0 Piping Sump I Trench Sensor(s) Model : 0794380-208 ❑ Piping Sump I Trench Sensor(s) Model : <br /> ❑ Fill Sump Sensor(s) Model : ❑ Fill Sump Sensor(s) Model : <br /> Mechanical Line Leak Detector Model : VMI 99LD-2000 ❑ Mechanical Line Leak Detector Model : <br /> i <br /> ❑ Electronic Line Leak Detector Model : ❑ Electronic Line Leak Detector Model : <br /> ❑ Tank Overfill / High -Level Sensor Model : ❑ Tank Overfill / High -Level Sensor Model : <br /> ❑ Other (specify equipment in Section E ) Model : ❑ Other (specify equipment in Section E ) Model : <br /> 132 : DISPENSERS/UDC's <br /> Dispenser # : 1 -2 Dispenser # : 3 =4 <br /> 0 Dispenser Containment Sensor(s) Model : 0794380 -208 E Dispenser Containment Sensor(s) Model : 0794380 -208 <br /> ❑ Shear Valves � ElShear Valves <br /> ElDispenser Containment Float(s) and Chain (s) ❑ Dispenser Containment Float(s) and Chain(s) <br /> Dispenser # : 5 =6 Dispenser # : 7 =8 <br /> 0 Dispenser Containment Sensor(s) Model : 0794380 -208 0 Dispenser Containment Sensor(s) Model : 0794380 -208 <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s) and Chain (s) ❑ Dispenser Containment Float(s) and Chain (s ) <br /> Dispenser # : Dispenser # : <br /> ❑ Dispenser Containment Sensor(s) Model : ❑ Dispenser Containment Sensor(s) Model : <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s ) and Chain (s) ❑ Dispenser Containment Float(s) and Chain(s) <br /> C . CERTIFICATION 1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines . <br /> Attached to this Certification is information (e . g , manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing th <br /> layout of monitoring equipment. For any equipment capable of generating such reports , I have also attached a copy of the report; (check all that apply <br /> ■ System set-up ■ Alarm History Report <br /> LTON <br /> Signature : WAENGINEERING, INC. <br /> Technician / Cert M Scott Beall / B45116 8319310 Date : December* 6, 2017 <br /> © 2017 Walton Engineering , Inc. <br />