Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> CERTIFICATION / TEST DATE : December 06 , 2017 <br /> Al . FACILITY A2 . OWNER <br /> Name Colonial Energy #40134 Name Colonial Energy, LLC . <br /> Address 1434 W. Yosemite Avenue, Manteca , CA 95337 Address 2860 N . Santiago Blvd , 2nd Floor, Orange , CA 92867 <br /> Phone # 916-285-7402 Phone # 714=761 =5426 <br /> Contact Station Manager Contact Victor Hassan <br /> D . RESULTS OF TESTING / SERVICING <br /> Make / Model of Monitoring System : Veeder-Root TLS -350 SN# 10914201805001 <br /> Software Version Installed . 331 . 00 <br /> Complete the following checklist : <br /> FM Yes ❑ No * Is the audible alarm operational? <br /> ■ Yes ❑ No * Is the visual alarm operational? <br /> ■ Yes ❑ No * Were all sensors visually inspected , functionally tested , and confirmed operational? <br /> ■ Yes ❑ No * Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper operation ? <br /> ❑ Yes ❑ No * If alarms are relayed to a remote monitoring station , is all communications equipment (e.g. modems) <br /> ■ N/A operational ? <br /> ■ Yes ❑ No * For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected ? If yes : which sensors initiate <br /> positive shutdown ? (check all that apply) ■ Sumplrrench sensors ; ■ Dispenser Containment Sensors . <br /> ■ Yes ❑ No * Did you confirm positive shut-down due to leaks and sensor failure/disconnection? <br /> ■ Yes ❑ No * For tank systems that utilize the monitoring system as the primary tank overfill warning device (i .e . no <br /> ❑ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% <br /> ■ Yes * ❑ No Was any monitoring equipment replaced ? If yes , identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E , below. <br /> ■ Yes * ❑ No Was any liquid found inside any secondary containment systems designed as dry systems ? <br /> (Check all that apply) ❑ Product; ■ Water. If yes , describe causes in Section E, below. <br /> ■ Yes ❑ No * Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable . <br /> ■ Yes ❑ No * Is all monitoring equipment operational per manufacturer's specifications ? <br /> * In Section E below, describe how and when these deficiencies were or will be corrected . <br /> E . COMMENTS <br /> TLS alarm light replaced . <br /> 89 grade leak detector replaced . <br /> Small amount of water found in 87 and 91 STP . <br /> © 2017 Walton Engineering , Inc. <br /> Page 2 of 3 <br />