My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 3:11:20 PM
Creation date
9/28/2020 9:19:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
FACILITY_NAME
H&S Energy Products,#3034
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> CERTIFICATION / TEST DATE : December 06 , 2017 <br /> Al . FACILITY A2 . OWNER <br /> Name Colonial Energy #40134 Name Colonial Energy, LLC . <br /> Address 1434 W. Yosemite Avenue, Manteca , CA 95337 Address 2860 N . Santiago Blvd , 2nd Floor, Orange , CA 92867 <br /> Phone # 916-285-7402 Phone # 714=761 =5426 <br /> Contact Station Manager Contact Victor Hassan <br /> D . RESULTS OF TESTING / SERVICING <br /> Make / Model of Monitoring System : Veeder-Root TLS -350 SN# 10914201805001 <br /> Software Version Installed . 331 . 00 <br /> Complete the following checklist : <br /> FM Yes ❑ No * Is the audible alarm operational? <br /> ■ Yes ❑ No * Is the visual alarm operational? <br /> ■ Yes ❑ No * Were all sensors visually inspected , functionally tested , and confirmed operational? <br /> ■ Yes ❑ No * Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper operation ? <br /> ❑ Yes ❑ No * If alarms are relayed to a remote monitoring station , is all communications equipment (e.g. modems) <br /> ■ N/A operational ? <br /> ■ Yes ❑ No * For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected ? If yes : which sensors initiate <br /> positive shutdown ? (check all that apply) ■ Sumplrrench sensors ; ■ Dispenser Containment Sensors . <br /> ■ Yes ❑ No * Did you confirm positive shut-down due to leaks and sensor failure/disconnection? <br /> ■ Yes ❑ No * For tank systems that utilize the monitoring system as the primary tank overfill warning device (i .e . no <br /> ❑ N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% <br /> ■ Yes * ❑ No Was any monitoring equipment replaced ? If yes , identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E , below. <br /> ■ Yes * ❑ No Was any liquid found inside any secondary containment systems designed as dry systems ? <br /> (Check all that apply) ❑ Product; ■ Water. If yes , describe causes in Section E, below. <br /> ■ Yes ❑ No * Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable . <br /> ■ Yes ❑ No * Is all monitoring equipment operational per manufacturer's specifications ? <br /> * In Section E below, describe how and when these deficiencies were or will be corrected . <br /> E . COMMENTS <br /> TLS alarm light replaced . <br /> 89 grade leak detector replaced . <br /> Small amount of water found in 87 and 91 STP . <br /> © 2017 Walton Engineering , Inc. <br /> Page 2 of 3 <br />