My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2021 10:36:10 AM
Creation date
9/28/2020 12:43:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0527728
PE
2351
FACILITY_ID
FA0018792
FACILITY_NAME
MARCH AND BIANCHI INC
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
01
SITE_LOCATION
1916 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L� <br /> Appendix VI DEC 18 2020 <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at I6VI Ild <br /> r,— .r' 7; . ICES <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, and California Code <br /> of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: March&Bianchi Chevron Bldg.No.: <br /> Site Address: 1916 March Lane City: Stockton Zip: 95207 <br /> Facility Contact Person: JEET Contact Phone No.: 209-954-0945 <br /> Make/Model of Monitoring System:VEEDER ROOT TLS 350 Date of Testing/Servicing: 11/16/2017 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: 1 UNLEADED Tank ID: DIESEL <br /> X In-Tank Gauging Probe. Model: VR MAG PROBE 1 X In-Tank Gauging Probe. Model:VR MAG PROB 1 <br /> X Annular Space or Vault Sensor. Model: VR 420 X Annular Space or Vault Sensor. Model:VR 420 <br /> X Piping Sump/Trench Sensor(s). Model: VR 208 X Piping Sump/Trench Sensor(s). Model:VR 208 <br /> X Fill Sump Sensor(s). Model: VR 208 X Fill Sump Sensor(s). Model:VR 208 <br /> 7 Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: VR ELLD X Electronic Line Leak Detector. Model: VR ELLD <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> X Other(specifies equipment type and model in Section E on Page 2). X Other specifies equipment t e and model in Section E on Page 2). <br /> Tank ID:2 PREMIUM Tank ID: <br /> X In-Tank Gauging Probe. Model:VR MAG PROB 1 ❑ In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model:VR 420 ❑ Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model:VR 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model:VR 208 ❑ Fill Sump Sensor(s). Model: <br /> -'Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> lectronic Line Leak Detector. Model:VR ELLD ❑ Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> X Other(specifies equipment t e and model in Section E on Page 2). ❑ Other(specifies equipment t e and model in Section E on Page 2). <br /> Dispenser ID:1/2 Dispenser ID:7/8 <br /> X Dispenser Containment Sensor(s). Model:VR 208 X Dispenser Containment Sensor(s). Model:VR 208 <br /> Shear Valve(s). ❑ Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). Dis enser Containment Floats and Chain(s). <br /> Dispenser ID:3/4 Dispenser ID: 9/10 <br /> X Dispenser Containment Sensor(s). Model:VR 208 X Dispenser Containment Sensor(s). Model:VR 208 <br /> J Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). --Dispenser Containment Floats and Chain(s). <br /> Dispenser ID:5/6 Dispenser ID: 11112 <br /> X Dispenser Containment Sensor(s). Model:VR 208 X Dispenser Containment Sensor(s). Model:VR 208 <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s Dispenser Containment Floats and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g. manufacturers'checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): System set-up Alarm history epert <br /> Technician Name(print):BRIAN ROTH Signature: <br /> Certification No.: B49349 License.No.: 920455 <br /> Testing Company Name:MID VALLEY CONSULTING Phone No.:(530)749-9892 <br /> Testing Company Address: 1097 BRONCO DRIVE,PLUMAS LAKE.CA 95961 Date of Testing/Servicing:11/16/2017 <br /> Monitoring System Certification Page 1 of 4 12/07 <br /> 1 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.