Laserfiche WebLink
Hazardous Waste Tank System October <br /> Final Assessment per CCR Title 22 <br /> Premier Hyundai of Tracy, 3480 Naglee Dr.Tracy, CA 95304 2014 <br /> Seismic Calculation <br /> Seismic Calculation -Waste Antifreeze Tank <br /> Cylindrical, Vertical, Closed Top, Flat Bottom <br /> Material of Construction: HDPE <br /> Shell Height, in 48.00 <br /> Shell Dia. In 36.00 <br /> Working Volume, gal 190.00 <br /> S.G. of contents 1.05 <br /> Tank Wall Thickness, in 0.30 <br /> Total Weight of Tank and Contents, lbs 1737.00 <br /> Overturning Moment.Arm, in 24.00 <br /> Resisting Moment Arm, in 18.00 <br /> Sds 0.89 <br /> Importance Factor 1.00 <br /> Fp, ASCE 7-10, 15.4-2 463.78 <br /> Overturning Moment inibf 11130.70 <br /> Resisting Moment, inibf 31266.00 <br /> Overturning Safety Factor- No Tension 2.81 <br /> Shear Strength of Anchor. Lbs 3432.00 <br /> # of Anchors 1.00 <br /> Factor of Safety for Shear 7.40 <br /> Seismic/Anchoring findings: The tank as d 'gned and operated and the <br /> containment area in which it is located are ad tely anchored and are <br /> seismically sound. Initials: <br /> Strandberg Associates 1(866) 388-0404 rwater a Drwaterguy.com 22 <br />