My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1829
>
2300 - Underground Storage Tank Program
>
PR0546066
>
INSTALL_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 2:27:27 PM
Creation date
10/12/2020 8:08:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2020
RECORD_ID
PR0546066
PE
2351
FACILITY_ID
FA0026050
FACILITY_NAME
7 ELEVEN STORE #41187
STREET_NUMBER
1829
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
CURRENT_STATUS
03
SITE_LOCATION
1829 N WILSON WAY
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN10 A Q U I N Environmental Health Department <br /> COUNTY <br /> 7 . The following items must be completed prior to scheduling the final inspection : <br /> a . An accurate and drawn to scale as- built drawing , which indicates the location of the UST system <br /> ( underground storage tanks , piping , auxiliary and monitoring equipment) with respect to buildings <br /> or other landmarks , per CCR 2711 ( a ) ( 8 ) , must be submitted to EHD . <br /> b . Copies of any required installation checklists (tank , etc . ) must be submitted to EHD . <br /> c . The designated operator ( DO ) training requirement must be satisfied , per CCR 2715 ( f) . <br /> d . Submit to CERS all applicable hazardous materials , hazardous waste , and UST submittals . The <br /> submittal must be approved by EHD . <br /> 8 . The installed UST system must be compliant with all applicable laws , regulations , and industry standards . <br /> All installation and testing shall be in compliance with manufacturer' s instructions and CCR 2635 and 2636 . <br /> All monitoring system components shall be listed in the State Water Resources Control Board ' s Local <br /> Guidance Letter ( LG ) 113 . <br /> 9 . All primary containment including any integral secondary containment system must be certified by an <br /> independent testing organization and labeled as required by the organization ( California Code of <br /> Regulations Title 23 Chapter 16 ( CCR ) 2631 ( b ) ; UL , ULC , ANSI , API , ASTM , etc . See CCR Table B for <br /> complete list. ) . Pursuant to Underwriters Laboratories Inc . ( UL) listing requirements , only those products <br /> bearing the UL mark will be considered listed . ANY PART/PRODUCT NOT MARKED WITH THE UL <br /> LABEL OR ANOTHER LISTED TESTING ORGANIZATION WILL BE REJECTED . All secondary <br /> containment system which is not an integral part of the primary containment shall be designed and <br /> constructed according to an engineering specification approved by a state registered professional engineer <br /> or according to a nationally recognized industry code or engineering standard , per CCR 2631 ( d ) . <br /> 10 . All metal components in direct contact with the ground , such as flexible connectors , swing joints , fittings , <br /> clamps , bands , and pumps , shall have adequate corrosion protection . <br /> 11 . Install concrete of sufficient thickness over USTs and around sumps and dispensers , according to the <br /> manufacturer' s written installation instructions and buoyancy calculations . <br /> 12 . All tank top openings that are connected to the primary space of the UST must have secondary <br /> containment, audible/visual alarm , and be vapor tight or terminate at grade . <br /> 13 . Sumps , including UDCs , must be constructed in a manner to prevent vapors from entering the backfill . <br /> 14 . All secondary containment must be constructed to prevent water intrusion and must be continuously <br /> monitored as required under HSC 25290 . 1 . <br /> 15 . Chase piping must be VPH monitored and included in its respective product piping vacuum monitoring <br /> zone . All vacuum zone volumes must be accurately programmed and their volumes adequate for their <br /> respective vacuum sensors . All sensors must be installed to detect a leak at the earliest opportunity . <br /> 16 . No additional shut off valves should be installed between the monitored interstitial spaces and their <br /> respective sensors . <br /> 17 . Overfill prevention shall satisfy CCR 2635 ( b ) (2 ) ( C ) , pursuant to the permit application . No ball floats shall <br /> be installed on vent lines to comply with overfill prevention requirements ( Code of Federal Regulations , <br /> Title 40 , section 280 . 20 (c) ) <br /> 18 . Hazardous material or waste cannot be released , intentionally or unintentionally , to the sewer/septic <br /> system , storm water system , or any other waters of the state . If a release occurs , it will be considered <br /> illegal hazardous waste disposal and will be subject to enforcement. <br /> 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.