Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.s'gov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CENTRAL GAS STOCKTON 3440 E MAIN ST, STOCKTON February 22, 2019 <br /> Item#I Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br /> are required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) <br /> at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a Class II violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Facility Operating Permit is not current in CERS. Any change of information must be updated in CERS within <br /> 30 days of the changes. Immediately log into CERS, update the required information, and submit for review by the <br /> EHD. <br /> UST Tank Information forms for the [note which ones] are not current in CERS. The tank forms for all three tanks <br /> indicate the vent piping is single-walled, but state there is a vent sump on site. Any change of information must be <br /> updated in CERS within 30 days of the changes. Immediately log into CERS, update the required information, and <br /> submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. In the UDC Monitoring section of the Monitoring <br /> Plans for all three tanks, Detection of Leak, UDC Leak Alarm, and Failure/Disconnection options were all left blank. <br /> In the UDC Monitoring section of the Monitoring Plans for all three tanks, Panel Manufacturer and Model have been <br /> filled in with Bravo float information. The dispenser leak monitoring system is not connected to a monitoring panel. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 106 CCR 2632(d)(2), 2634(e) Failed to have an approved UST response plan. <br /> The response plan is not current and/or not approved by the EHD. The response plan must be uploaded to the <br /> California Environmental Reporting System (CERS). Immediately log into CERS, upload the completed form, and <br /> submit for review by the EHD. Ensure a copy is available for inspection at any time. <br /> This is a Class II violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The Monitoring Site Plan (map) does not include annular <br /> sensors. A site plan must be submitted identifying the locations where monitoring will be performed. Immediately <br /> log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of <br /> the UST Monitoring Site Plan. <br /> This is a Class II violation. <br /> FA0006423 PR0231173 SCO01 02/22/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 8 Underground Storage Tank Program OIR <br />