My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013457
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CARDINAL
>
731
>
2600 - Land Use Program
>
PA-1900061
>
SU0013457
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2020 8:32:27 AM
Creation date
10/28/2020 8:30:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013457
PE
2626
FACILITY_NAME
PA-1900061
STREET_NUMBER
731
Direction
S
STREET_NAME
CARDINAL
STREET_TYPE
AVE
City
STOCKTON
Zip
95215-
APN
15911024
ENTERED_DATE
6/30/2020 12:00:00 AM
SITE_LOCATION
731 S CARDINAL AVE
RECEIVED_DATE
6/26/2020 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 . A building permit for each separate structure or building is required . Submit plans , <br /> Specifications and supporting calculations , prepared by a Registered Design Professional <br /> ( architect or engineer ) for each structure or building , showing compliance with The 2016 <br /> California Building , Existing Building , Mechanical , Plumbing , Electrical , Energy and Fire codes <br /> as may be applicable . Plans for the different buildings or structures may be combined into a <br /> single set of construction documents . <br /> 2 . A grading permit will be required for this project . Submit plans and grading calculations , <br /> including a statement of the estimated quantities of excavation and fill , prepared by a <br /> Registered Design Professional . The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code . The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code . <br /> 3 . The required plans must be complete at the time of submittal for a building permit . Plans must <br /> address building design and construction , fire and life safety requirements , accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances . A <br /> complete set of plans must include fire sprinkler plans , truss design submittals , metal building <br /> shop drawings , structural plans and calculations , plumbing , electrical and mechanical drawings <br /> and energy report . <br /> 4 . A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading . All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings . <br /> 5 . For each proposed new building , provide the following information on the plans : <br /> A . Description of proposed use <br /> B . Existing and proposed occupancy Groups <br /> C . Type of construction <br /> D . Sprinklers ( Yes or No ) <br /> E . Number of stories <br /> F . Building height <br /> G . Allowable floor area <br /> H . Proposed floor area <br /> I . Occupant load based on the CBC <br /> J . Occupant load based on the CPC <br /> 6 . If high piled combustible storage is to be used in a building , an automatic fire sprinkler system <br /> will be required . <br /> 7 . Accessible routes shall be provided per CBC § 11 13 -206 . At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones ; public streets and sidewalks ; and public transportation stops to the accessible building <br /> or facility entrance they serve . Where more than one route is provided , all routes must be <br /> accessible . § 11 13 -206 . 2 . 4 <br /> 8 . At least one accessible route shall connect accessible buildings , accessible facilities , <br /> accessible elements and accessible spaces that are on the same site . § 11 13 -206 . 2 . 2 <br /> 9 . At least one accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility , including mezzanines , which are <br /> otherwise connected by a circulation path . § 11 13 -206 . 2 . 4 <br /> 10 . Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> PA- 1900061 — Amended Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.