Laserfiche WebLink
Table 3. Assumptions for Nitrate Loading Calculation <br /> Variable Value Units Description <br /> Q 400 gpd Effluent flow rate <br /> Nw 35 mg/L-N Effluent stream concentration <br /> A 1.46 acres Site area <br /> Nb 0.30 mg/L-N Concentration of rain <br /> d 0.35 constant Denitrification factor <br /> R 4.92 inches per year Recharge rate of rainfall <br /> W 3.7 inches per year Uniform waste water loading (calculated) <br /> The details of the nitrate loading calculation are included in Plate 15. The results of the <br /> calculation are presented in the following table. <br /> Table 4. Result of Nitrate Loading Calculation <br /> Variable Value Units Description <br /> Nc 9.9 mg/L-N Long-term average concentration of percolating effluent <br /> The US EPA recommended MCL for nitrate in drinking water is 10 mg/L-N. In a worst- <br /> case situation, the maximum buildup of nitrates in the aquifer from the use of septic <br /> systems on the Site is predicted to be 9.9 mg/L-N. The result of the nitrate loading <br /> estimate is below the maximum drinking water standard. <br /> Discussion of Nitrate Loading Results <br /> Total Nitrate Impact <br /> Based on the method and assumptions described, the result of the nitrate loading <br /> estimate indicates that the existing and proposed development on the Site should not <br /> cause a buildup of nitrates in the aquifer above 10 mg/L-N. No nitrate mitigation is <br /> recommended. <br /> LOGE 20-44 Page 11 <br />