My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINNE
>
1728
>
2800 - Aboveground Petroleum Storage Program
>
PR0540694
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2021 8:48:08 AM
Creation date
11/18/2020 10:59:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0540694
PE
2832
FACILITY_ID
FA0009536
FACILITY_NAME
CONCRETE INC
STREET_NUMBER
1728
STREET_NAME
LINNE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25311027
CURRENT_STATUS
01
SITE_LOCATION
1728 LINNE RD
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 3A <br />INTEGRITY TESTING PROGRAM-SCOPE & FREQUENCY <br />KRC TRACY PLANT <br />li Te~; I <br />#1 <br />Tank Volume (GA"' 10,000 <br />Tank Type Horz Tnk <br />Ul2085 <br />Contents Diesel <br />CRDM Sides, Base <br />Seepage <br />RPB AS : design and <br />PCC footing <br />I STI Cateaor·v Category 1 <br />' Visual inspection by facility personnel (as M <br />II per checklist App B) A <br />I' External inspection by certified inspector (as 1 Oyr* <br />I per STI Std SP-00'!) <br />I External inspection by certified inspector (as <br />I perSTi Std SP-001\ <br />EE <br />, <br />I <br />' Tank tightness test nla <br />meeting req'ts of <br />40 CFR 280 (USTs) <br />Legend. <br />CRDrv1: Continuous Release Detection Method <br />RPB: Release Prevention Barrier <br />M: Monthly Q: Quarterly <br />A: Annual <br />* Or ear!ier as recommended by certified inspector <br />based on findings from extemat :nspection <br />J ~2/ #3 <br />Oit vi Jvvl"~"" <br />500 Est. 200 GA <br />Horz Tnk UL 2085 Utility Co Elect <br />Rectangular Transformer <br />Diesel Off Hiahwav Heat Transfer <br />Sides, Base Sides, Base <br />Seepage Seepage <br />AST design and Concrete Pad <br />PCC footing <br />Category 1 Category 1 <br />M M <br />A A <br />10 yr* 10yr* <br />EE EE <br />n/a n/a <br />EE: Inspection not required given use <br />of environmentally equivalent measure