My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINNE
>
1728
>
2800 - Aboveground Petroleum Storage Program
>
PR0540694
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2021 8:48:08 AM
Creation date
11/18/2020 10:59:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0540694
PE
2832
FACILITY_ID
FA0009536
FACILITY_NAME
CONCRETE INC
STREET_NUMBER
1728
STREET_NAME
LINNE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25311027
CURRENT_STATUS
01
SITE_LOCATION
1728 LINNE RD
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tar. 9roves hr <br />SAN JOAQUIN <br />-COUNTY <br />Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />i <br />Facility Name: <br />CONCRETE INC <br />Facility Phone: <br />(209) 839-4169 <br />Date: <br />November 17, 2020 <br />Facility Address: <br />1728 LINNE RD, TRACY, CA 95376 <br />CERS ID: <br />10182761 <br />Inspection Contact: <br />Rudy Belmonte <br />Title: <br />Batchman <br />Phone: <br />(209) 839-4169 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2832- AST FAC 10 K - </=100 K GAL CUMULATIVE <br />Consent For: <br />El Inspection El Photos El Samples <br />Consent Given By: <br />Rudy Belmonte, Batchman <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Title 40 Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />Aboveground Petroleum Storage Act <br />101 HSC 25270.6(b) Failed to pay APSA program annual fees DV oR oCOS <br />102 HSC 25270.4.5(a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112 oV oR oCOS <br />103 HSC 25270.6(a) Failed to file HMBP or annual facility tank statement oV oR oCOS <br />104 HSC 25270.8 Failed to report spills or releases of 42 gallons (one barrel) or more oV oR oCOS <br />105 CFR 112.1(b)(3), 112.2 Failure to properly close tanks when making a claim of permanently closed oV ER oCOS <br />106 HSC 25404.1.2 Failed to submit a certification and written response within 30 days for minor violations oV oR oCOS <br />107 HSC 25270.2(a)(4) Failure to prepare SPCC plan when facility no longer meets oil-filled electrical equipment exclusion oV oR oCOS <br />108 HSC 25270.4.5(a) Failure of conditionally exempt facility to conduct inspections or install secondary containment V oR (EGOS <br />109 HSC 25270.2(o)(1)(C) <br />(iv)(III) <br />Failure to have secondary containment and/or leak detection if TIUGA piping cannot be viewed DV oR oCOS <br />110 HSC 25404(e)(4) Failed to report program data in the California Environmental Reporting System (CERS) oV oR oCOS <br />111 HSC 25270.2(a)(8) Failure of a TIUGA with less than 55 gallons capacity to have secondary containment and a log V oR oCOS <br />112 CFR 112.20(e) Failure to complete and maintain a Substantial Harm Criteria certification DV oR COS <br />Requirement to Prepare and Implement a SPCC Plan <br />201 CFR 112.3(d) Failure to have a licensed PE properly review and certify the SPCC plan oV ER H COS <br />202 CFR 112.3(e)(1) Failed to maintain a copy of the Plan on site oV ER oCOS <br />203 CFR 112.3 Failure to implement the SPCC Plan oV oR COS <br />204 CFR 112.3(g) Failure to prepare SPCC Plan when facility no longer meets Qualified Facility criteria DV oR oCOS <br />205 CFR 112.3, 112.6 Failure to prepare SPCC Plan that meets all applicable requirements oV oR oCOS <br />206 CFR 112.3(d)(1) Failure of owner to assure that the PE makes all required attestations in the Plan ri V E R ii COS <br />Amendment of SPCC Plan by Owners or Operators <br />301 CFR 112.5(a) Failed to amend Plan as necessary oV oR DCOS <br />302 CFR 112.5(b) Failed to review Plan once every five years and/or implement any resulting amendments oV oR DCOS <br />303 CFR 112.5(c) Failed to have a PE certify technical amendments DV oR oCOS <br />304 CFR 112.5(a), 112.5(b) Failure to implement SPCC plan amendments within 6 months oV oR oCOS <br />Qualified Facility - Tier I <br />401 CFR 112.6(a), 112.6(b) Tier I Qualified Facility Plan not certified by the owner or a PE DV oR DCOS <br />402 CFR 112.6(a)(2) Owner of Tier I Qualified Facility failed to self certify technical amendment oV oR COS <br />403 CFR 112.6(a)(3)(i) Plan failed to predict direction/rate of flow/total quantity of oil potentially discharged oV oR oCOS <br />FA0009536 PR0540694 SC001 11/17/2020 <br />EFID 28-01 Rev. 9/16/2020 Page 1 of 5 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.