My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
1600 - Food Program
>
PR0517445
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2023 11:37:32 AM
Creation date
12/2/2020 4:01:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0517445
PE
1625
FACILITY_ID
FA0013430
FACILITY_NAME
LOVES COUNTRY STORES OF CALIFORNIA #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24517054
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br /> MECHANICAL SYMBOLS p 10" DIA DUCT UP TO ROOF. <br /> O2 4" METAL DRYER EXHAUST DUCT UP THRU ROOF. TERMINATE <br /> WITH GOOSENECK FITTING AND BACKDRAFT DAMPER. A <br /> U INSULATED FLEXIBLE DUCT O REMOVE DRYER DUCT AND SEAL WALL PENETRATION WEATHER <br /> TIGHT. FINISH TO MATCH ADJACENT SURFACE. <br /> O4 CONNECT NEW EXHAUST FAN INTO EXISTING DUCTWORK WITH <br /> 6" ROUND DUCT AND BACKDRAFT DAMPER. <br /> VOLUME DAMPER WITH LOCKING QUADRANT O EXTEND FLEX DUCT AS NECESSARY TO CONNECT NEW DIFFUSER Architect of Record: <br /> TO EXISTING BRANCH DUCT. <br /> Mariah B. Meyer <br /> REMOVE <br /> PRESSURE REDUCING APIPE <br /> OHE Metcalf Avenue <br /> THISLOCATION. EXTEND HORIZONTALLY WITHL" (5PSIG) Suite 300 <br /> BRANCH DUCT WITH 45e BOOT FITTING BELOW GRADE AS SHOWN. Overland Park,KS 66204 <br /> O7 STUB UP 1" GAS PIPE. PROVIDE AND INSTALL SECONDARY www.brrarch.com <br /> GAS REGLUATOR (5 PSIG TO 11" W.C.) AND MAIN SHUTOFF <br /> J) ELBOW WITH TURNING VANES VALVE. EXTEND 3" GAS PIPE UP AND PENETRATE EXTERIOR Tel:913-262-9095 <br /> WALL ABOVE CEILING. Fax:913-262-9044 <br /> OTAPLNEW 3' GAS SUPPLY INTO EXISTING 3" GAS PIPE ABOVE <br /> BRANCH DUCT WITH BELLMOUTH SPIN—IN <br /> FITTING WITH MANUAL VOLUME DAMPER O REMOVE 3" GAS PIPE FROM EXISTING PRESSURE REDUCE <br /> VALVE TO INSIDE ROOM AND CAP. BRANCH LINE TO WATER <br /> HEATERS SHALL REMAIN INTACT. W a Lw) w r <br /> — — — — — — — — — EQUIP. WITH FLEXIBLE DUCT CONNECTION 10 APPROXIMATE LOCATION OF EXISTING GAS SERVICE LINE. � oz www 1C_)_0z <br /> Z <br /> VERIFY BEFORE ANY EXCAVATION WORK. EXISTING GAS METER W 0 a r���w p w o � <br /> I S LOCATED NEAR THE STREET. � W,cr=z LL X w a.of U 0 0 <br /> ¢�~mLL�ww00DL[j�p <br /> 11 14" DIA TRANSFER DUCT CONNECTING TWO GRILLS FOR 0-<3:F-¢:50w-<0::)z. <br /> w <br /> 3 RETURN, EXHAUST OR FRESH AIR DUCT UP EXHAUST AIR MAKE-UP. z w <br /> 30 I 12 EX I STING <br /> T I NGCFMTON RTU-2 ON ROOF. BALANCE SUPPLY AIRFLOW O 3 W zwN Z)0 o p w= <br /> U Cn O p z <br /> zaY�O~Ow�>w19 ztr❑ <br /> �� RETURN, EXHAUST OR FRESH AIR DUCT DOWN 13 EXISTING 4 TON RTU-4 ON ROOF. BALANCE TO SUPPLY D a g z J =g w w(Da w ir <br /> + ❑+ AIRFLOW TO 945 CFM. mol__OX5�woxp= <br /> �wz��Owwa'Oo�O�� <br /> FO1 I 14 REMOVE 10" DIA BRANCH DUCT SERVING EXISTING DIESEL x fn o¢D fn rc w fr z x zO <br /> SUPPLY AIR DUCT UP <br /> DESK. TAP MAIN WITH NEW 14x8 RECTANGULAR DUCT. r U D 0 Co a D o of 0-Q r a a r <br /> _- , _ ® <br /> O EF-B---® 15 OPEN ENDED 12" DIA RETURN DUCT THRU WALL. <br /> I I 2 ,00 CFMJ I5 s6 4W GENERAL NOTESi CONSULTANT LOGO <br /> 5o 11 1 1 E II - W so o �Xy SUPPLY AIR DUCT DOWN <br /> 8"0 RA II I 10"0 II 1. ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH THE <br /> 200 80 � I I 395 2 12"0(E) is A REQUIREMENTS OF THE 2019 CALIFORNIA MECHANICAL CODE. <br /> 200 I I I <br /> — ;x: 10x10 REGISTER, SIZE, TYPE & CFM <br /> II I SA 2. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING <br /> 15 � I I 2 s 0 250 CONSTRUCTION PRIOR TO SUBMITTING HIS BID. NO EXTRAS <br /> 400 ------------ WILL BE PAID DUE TO UNANTICIPATED EXISTING <br /> LEFT7— B CONDITIONS. <br /> s6 10x10 REGISTER, SIZE, TYPE & CFM <br /> II I I I X 250 3. CONTRACTOR SHALL SCHEDULE AND EXECUTE ALL WORK WITH <br /> II I 11 I i 50 REGARD TO THE OWNER'S USE OF THE BUILDING. <br /> O 4 ID 10"0 REGISTER SIZE TYPE & CFM 4. PLANS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. REFER engineering consultants <br /> � E i t t eng g TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. <br /> + I F6" v ` --------- —J 250 650 E.Algonquin Road I Suite 250 1 Schaumburg,IL 60173 <br /> p 5. BRANCH DUCTS SHALL BE THE SAME SIZE AS DIFFUSER NECK T 913.322.1400 www.rtmec.com <br /> 0 945 4 UNLESS NOTED OTHERWISE. <br /> 13 5O <br /> 011sro'co) <br /> 6. ROUND TAKE-OFF FITTINGS FROM RECTANGULAR DUCTWORK <br /> SHALL BE MADE WITH BUCKLEY BELLMOUTH FITTINGS, OR <br /> ZVE APPROVED EQUAL. W°° 6"0 OLE_ <br /> 50 EF 6 X 7. PROVIDE TURNING VANES IN ALL ELBOWS Qz200 8. EQUIVALENT MANUFACTURERS OF GRILLES REGISTERS AND p O <br /> S7 _ <br /> DIFFUSERS SHALL BE CARNES, TITUS, KRUEGER, OR U <br /> 5 ANEMOSTAT. U) O <br /> 1 2 TYP 5�w 9. CONDENSATE DRAINS SHALL BE INSTALLED PER THE (� LU W <br /> 30 30 o INTERNATIONAL MECHANICAL CODE AND RELATED DETAILS./) <br /> w0 o DISCHARGE WITH AN AIR GAP TO THE CLOSEST WASTE Y <br /> N 12 700 RECEPTOR OR AS NOTED ON PLANS. O U) W <br /> a 4 10. ALL AIR TERMINALS NOTED WITH AN "(E)" ARE EXISTING TO uJ <br /> 14 REMAIN. BALANCE AIRFLOW TO SPECIFIED VOLUME IN TAG. /r LL Ij <br /> 1ox,0(E) 11. ALL DUCT NOTED WITH AN "(E)" IS EXISTING TO REMAIN. 1 N 0_ co <br /> I I <br /> 16x,0(E) 22x16(E) <br /> I <br /> 225 CFM I SB X Z z w l <br /> S§E I I 6� ` wO <br /> a-0w S"0 i /�' � Q <br /> N 220 i i EF-4 O <br /> fro0 <br /> 0020O <br /> CD <br /> loLo�� N <br /> lo <br /> M <br /> + p ❑+ \ 4 O <br /> I <br /> LU <br /> 24x16(E) 32x,6(E) <br /> 16x14(E) <br /> z <br /> 00 <br /> ®T 4 O <br /> g,0 16x14 <br /> 200 <br /> ISSUE BLOCK <br /> NO. DATE DESCRIPTION <br /> I <br /> I <br /> I <br /> J <br /> �/. O <br /> 8 <br /> 9 <br /> CHECKED BY: BJK <br /> J <br /> N <br /> DRAWN BY: JHF <br /> DOCUMENT DATE: 09/01/2020 <br /> E PROTO TYPE: <br /> 8"0 fro g'0 <br /> 75 75 200PROTO CYCLE: <br /> LJ0 <br /> 14— <br /> v <br /> C9 <br /> a <br /> 4 TYP PROFESSIONAL SEAL <br /> Sro3E E <br /> 75 200 O Q�QF ESS l04 l <br /> � l c� <br /> / 500 <br /> 0 o w m <br /> No. 33167 7-0 <br /> 0 Exp. 9-30-21 <br /> 6 7Qr �� signed by Cameron Collins <br /> US <br /> E=came ron.col li ns@nmassociates.com, <br /> 10 Cameron Collins O=RTM Engineering,OU=RTM, <br /> CN-Cameron Collins <br /> Date:2020.08.31 11:20:17-05'00' <br /> MECHANICAL PLANS <br /> 1 HVAC AND GAS PLAN <br /> M201 SCALE 3/1611-11-011 NORTH <br /> SHEET: <br /> M201 <br /> Copyright Notice:This drawing was prepared for use on a specific site contemporaneously with <br /> BRR Original printed on recycled paper its Issue date and it Is not s,it,bl,f,,,,,on a different project site or at a later time.use of this <br /> drawing for reference or example on another project requires the services of properly licensed <br /> architects and engineers.Reproduction of this drawing for reuse on another project is not <br /> authonzed and may be contrary to the law. <br />
The URL can be used to link to this page
Your browser does not support the video tag.