Laserfiche WebLink
EXHAUST FAN SCHEDULE <br /> EST. ESP. VOLTS/ MOTOR <br /> MARK MANUFACTURER MODEL CFM (IN W.G.) PHASE WATTS NOTES <br /> EF-4 GREENHECK SP-8150 150 0.3 120/1 19.2 1-5 <br /> EF-5 GREENHECK SP-8150 150 0.3 120/1 19.2 1-5 <br /> EF-6 GREENHECK SP-8150 150 0.3 120/1 19.2 1-5 <br /> Architect of Record: <br /> EF-7 GREENHECK SP-8150 150 0.3 120/1 19.2 1-5 <br /> Mariah B. Meyer <br /> EF-8 GREENHECK SP-8150 150 0.3 120/1 19.2 1-5 <br /> 8131 Metcalf Avenue <br /> Suite 300 <br /> Overland Park,KS 66204 <br /> www.brrarch.com <br /> NOTES: <br /> Tel:913-262-9095 <br /> 1. RUN CONTINUOUS <br /> Fax:913-262-9044 <br /> 2. FURNISHED BY OWNER <br /> 3. DIRECT DRIVE <br /> 4. DISCONNECTING MEANS <br /> 5. BACKDRAFT DAMPER <br /> w w <br /> LLJ v c=n r O <br /> Diiz� w2WXW' Uz 'X <br /> LU wa~pw~w, ��z z <br /> GRILLES, REGISTERS DIFFUSER SCHEDULE a�~�LLW0T'g ~><ww �¢gLL a�S❑z¢CO�Ua�t�Q Z Q❑Q'oL"U WzWW�U� <br /> MINIMUM MAX MAX PRESS O 3:J_W 9 Z 0�W°'o <br /> FRAME FRAME VOLUME MAX NC THROW THROW DROP Q Z o ° Z a <br /> MARK MANUFACTURER MODEL APPLICATION FINISH SIZE TYPE DAMPER (DB) (FT) (FT) (IN.W.G.) NOTES o o o a w o x wo a W<0, F <br /> SA NAILOR UNI SUPPLY WHITE 24 x24" LAY—IN N 25 4 17 0.1 1-5 �w z I-"o w o o❑T o <br /> (n r��oma0000_ua¢rQa0 <br /> SB NAILOR 4320CBA SUPPLY WHITE 16:x16" SURFACE N 25 7 17 0.1 1-5 <br /> RA NAILOR 6145H RETURN WHITE 24 x24" LAY—IN N 25 -- -- 0.05 1-5 <br /> GENERAL NOTES: CONSULTANT LOGO <br /> A. MINIMUM THROWS ARE BASED ON 50 FEET PER MINUTE VELOCITY. <br /> B. MAXIMUM THROWS ARE BASED ON 150 FEET PER MINUTE VELOCITY. <br /> C. OPPOSED BLADE DAMPERS SHALL BE PROVIDED ON ALL DIFFUSERS REQUIRING VOLUME DAMPERS. <br /> NOTES: <br /> 1. BORDER TYPES SHALL BE COMPATIBLE WITH ARCHITECTURAL CEILING TYPE FOR THE ROOM IN WHICH THE AIR DEVICE IS LOCATED r m <br /> 2. REFER TO HVAC PLANS FOR AIR QUANTITIES AND NECK SIZE OF EACH AIR DEVICE <br /> 3. ALL AIR DEVICES SHALL BE TESTED IN ACCORDANCE WITH ASHRAE STANDARD 70-91. <br /> 4. NC VALUES ARE BASED UPON A 10dB ROM ATTENUATION. engineering consultants <br /> 5. OWNER PROVIDED AND CONTRACTOR INSTALLED. 650 E.Algonquin Road I Suite 250 1 Schaumburg,IL 60173 <br /> T:913.322.1400:www.rtmec.com <br /> LU <br /> U Z <br /> Q <br /> 00 <br /> � Q <br /> U) U <br /> 1 O <br /> DLUL <br /> LULU <br /> Y <br /> RADIUS ELBOW WITH O w LU <br /> CENTERLINE RADIUS <br /> OF 1.5xDUCT WIDTH LL w <br /> (INTERIOR MITERED < C/) <br /> CORNERS ARE NOT U N o <br /> 4xDUCT WIDTH ALLOWED) <br /> MINIMUM O U O <br /> zZ w I= <br /> SUPPORT FROM— �rr O� O LL1 00 <br /> STRUCTURE MAIN OR BRANCH DUCT �� ^^ a- Q <br /> I..L <br /> FLEXIBLE DUCT 0 o <br /> 5'-0" MAXIMUM LENGTH N <br /> CD <br /> N <br /> MITERED ELBOW \45* BRANCH DUCT C° <br /> WITH TURNING FITTING PER 3/M21 <br /> VANES <br /> FACTORY FABRICATED, <br /> RECTANGULAR TO ROUND LU <br /> CONTROL VOLUME DAMPER/>4] BRANCH TAKE—OFF WITH g <br /> DAMPER AS SHOWN <br /> z <br /> m <br /> BELL MOUTH FITTING O <br /> EXTERNAL FLEXIBLE DUCTWORK ELBOW— DUCTWORK <br /> CONSTRUCTION DETAIL <br /> THERMAFLEX FLEXFLOW ELBOW OR A ISSUE BLOCK <br /> APPROVED EQUIVALENT L <br /> CEILING <br /> �01 NO SCALE NO. DATE DESCRIPTION <br /> �l 1� GALV. IRON STRAP SECURE TO STRUCTURE <br /> OR ALUM. SEE ABOVE AS RECOMMENDED HANGER ROD SEE <br /> TABLE FOR SIZE BY SMACNA TABLE FOR SIZE <br /> SUPPLY DIFFUSER <br /> 4 CEILING DIFFUSER DETAIL <br /> M301 NO SCALE <br /> CHECKED BY: BJK <br /> I I II <br /> DRAWN BY: JHF <br /> CLOTHES DRYER EXHAUST SHALL DOCUMENT DATE: 09/01/2020 <br /> NOT BE CONNECTED TO A VENT <br /> 3'-0"CONNECTOR, VENT, OR CHIMNEY PROTO TYPE: <br /> (IMC 504.4); TERMINATE WITH SHEET METAL SCREWS NUT & WASHER <br /> ROOF GOOSENECK FITTING TO BOTTOM OF DUCT AT END OF ROD PROTO CYCLE: <br /> INSULATE INDOOR DRYER EXHAUST WITH TYPE "A" TYPE "B" <br /> 2—INCH THICK EXTERIOR DUCT WRAP <br /> WITH FRK FACING. PROFESSIONAL SEAL <br /> ANY NECESSARY OFFSETS SHALL BE DUCT HANGER SCHEDULE <br /> MADE IN A GRADUAL MANNER NO <br /> GREATER 45' <br /> DUCT TYPE HANGER STRAP ROD ANGLE Q�oFEss/py <br /> -DUCTS SHALL NOT BE CONNECTEDSIZE OF SPACING SIZE SIZE FOR �p oN K c 9( <br /> OR INSTALLED WITH SHEET METAL ( INCH) HANGER (FT) ( INCH) BRACING 0��Fyc <br /> SCREWS OR OTHER FASTENERSv Z <br /> THAT WILL OBSTRUCT THE EXHAUST UP TO 12 A 8'-0" <br /> 1 "x16GA N.A. N.A. � r*1 <br /> 13 TO 18 A 8'-0" 1 "x16GA N.A. N.A. No. 33167 <br /> rri <br /> FLOW (IMC 504.4) 19 TO 30 A/B 8'-0" 1 "x16GA 1/4" 1-1/2"x1-1/2"x1/8" Exp. 9-30-21 <br /> 0 31 TO 42 B 8'-0" N.A. 1/4" 1-1/2"0-1/2"0/8" <br /> 43 TO 54 B 8'-0" N.A. 1/4" 1-1/2"0-1/2"0/8" LP �F GQV P <br /> F-1 PROVIDE ACCESS DOOR FOR 55 TO 60 B 8'-0" N.A. 1/4" 1-1/2"x1-1/2"x1/8" �,� , CHANE �\ <br /> CLEANOUT AT BASE OF DRYER 61 TO 84 B 8'-0" N.A. 1/4" 1-1/2"x1-1/2"x3/16" 01 <br /> EXHAUST RISER (IMC 504.3) / 1-1/3"x1-1/2"x3/16" signed by Cameron Collins <br /> 85 TO 96 B 8'-0" N.A. 1 4" =us, <br /> N E=Cameron.collins@rtmassociates.com, <br /> OVER 96 B <br /> 81-01, N.A. 3/8 2%2 x1/4" ameron Collins O=RTM Engineering,OU=RTM, <br /> R/D=1.5 lTl <br /> CN-Cameron Collins <br /> Date-2020.08 31 11:18:42-05'00' <br /> NOTES: <br /> FLOOR L— <br /> 1 ) FOR SEVERAL DUCTS ON ONE HANGER, TYPE "B" MAY BE USED. SIZE OF <br /> INCREASE DUCT SIZE FROM 8" TO 10" HANGER WILL BE SELECTED ON THE SUM OF DUCT WIDTHS EQUAL TO MAX <br /> WITH ECCENTRIC OR CONCENTRIC WIDTH OF DUCT SCHEDULE. <br /> TRANSITION AS REQUIRED 2) ON TYPE "A" HANGER, PROVIDE 3 HANGERS AT EACH TAKE—OFF OR BRANCH. <br /> HVAC SCHEDULES AND <br /> 3 DRYER DUCT SCHEMATIC- 1 DUCT SUPPORT DETAIL DETAILS <br /> M301 NO SCALE M301 NO SCALE <br /> SHEET: <br /> M301 <br /> Copyright Notice:This drawing was prepared for use on a specilc site contemporaneously with <br /> BRR Original printed on recycled paper its iss„e date and it is not suitable for ase on a different projea site or at a later time.use of this <br /> drawing for reference or example on another project requires the services of properly licensed <br /> architects and engineers.Reproduction of this drawing for reuse on another project is not <br /> authorized and may be contrary to the law. <br />