Laserfiche WebLink
CA GREEN CODE REQUIREMENTS , <br /> 1. PER CALGREEN SECTION 5.303.2, PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN <br /> IN TABLE 5.303.2.3. EXCEPTION: BUILDING THAT DEMONSTRATE 20% OVERALL WATER USE REDUCTION. IN THIS <br /> CASE, A CALCULATION DEMONSTRATING A 2% REDUCTION IN THE BUILDING "WATER USE BASELINE," AS <br /> ESTABLISHED IN TABLE 5.303.3 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATIONS TO <br /> THE BUILDING. <br /> MAXIMUM FIXTURE FLOW RATES: <br /> FIXTURE TYPE MAXIMUM FLOW RATE <br /> LAVATORY FAUCETS-NONRESIDENTIAL 0.5 GPM ® 60 PSI <br /> KITCHEN FAUCETS 1.8 GPM @ 60 PSI z <br /> METERING FAUCETS 0.25 GALLONS/CYCLE 0 <br /> WATER CLOSETS 1.28 GALLONS/FLUSH <br /> URINALS 0.5 GALLONS/FLUSH <br /> w <br /> 2. PER CALGREEN SECTION 5.303.3.1, THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT 0 <br /> EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE <br /> CRITERIA OF THE US EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE <br /> FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO <br /> REDUCES FLUSHES AND ONE FULL FLUSH. <br /> 3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE <br /> DEPOSITING, STORAGE, AND COLLECTION OF NONHAZARDOUS MATERIALS FOR RECYCLING. PER SECTION <br /> 5.410.1.1 ANY ADDITION OR ALTERATION RESULTING IN LESS THAN A 30% INCREASE IN THE TENANT SPACE <br /> FLOOR AREA IS EXEMPT FROM THIS REQUIREMENT. <br /> 4. PER CALGREEN SECTION 5.504.3, AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE <br /> CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL <br /> DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, w <br /> SHEET METAL, OR OTHER APPROVED METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH Q <br /> MAY ENTER THE SYSTEM. o <br /> 5. PER CALGREEN SECTION 5.504.4.1, ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, <br /> SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH TABLE 5.504.4.1 AND 5.504.4.2. w <br /> Of <br /> SEALANT VOC LIMIT: ARCHITECT OF RECORD: <br /> ARCHITECTURAL 250 SED ARC/ <br /> y/ <br /> DECK 760 i� <br /> NONMEMBRANE ROOF 300 V CRAIG S. <br /> ROADWAY 250 BLUME- <br /> SINGLE-PLY ROOF MEMBRANE 450 <br /> OTHER 420 * NO.-C-31661 <br /> Q .331 2021 (q <br /> y <br /> 6. PER CALGREEN SECTION 5.504.4.3, ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE �cSC ,�y <br /> 5.504.4.3. d0 �o <br /> VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS: <br /> INDOOR CARPET ADHESIVES 50 <br /> CARPET PAD ADHESIVES 50 � , O <br /> OUTDOOR CARPET ADHESIVES 150 <br /> WOOD FLOORING ADHESIVES 100 <br /> RUBBER FLOOR ADHESIVES 60 <br /> SUBFLOOR ADHESIVES 50 <br /> CERAMIC TILE ADHESIVES 65 <br /> VCT AND ASPHALT TILE ADHESIVES 50 <br /> DRYWALL AND PANEL ADHESIVES 50 <br /> COVE BASE ADHESIVES 50 <br /> MULTIPURPOSE CONSTRUCTION ADHESIVES 70 W <br /> STRUCTURAL GLAZING ADHESIVES 100 m <br /> SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 D a ° <br /> OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 O r <br /> SPECIALTY APPLICATIONS PVC WELDING 510 Q ° <br /> cj <br /> } � 3 <br /> CPVC WELDING 490 a o 3 <br /> ABS WELDING 325 <br /> PLASTIC CEMENT WELDING 250 o °' <br /> ADHESIVE PRIMER FOR PLASTIC 550 0 � 3-p `o N N <br /> CONTACT ADHESIVE 80 o V o °`o ° °�_'° `o <br /> SPECIAL PURPOSE CONTACT ADHESIVE 250 0 J a ° <br /> STRUCTURAL WOOD MEMBER ADHESIVE 140 ° <br /> N ` °' ` ° p <br /> a `oa�v° � <br /> TOP AND TRIM ADHESIVE 250 o o-o <br /> J ;, ° c <br /> c -p a� 0o0� <br /> SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 0 �+ ° °'ate n+' a N <br /> PLASTIC FOAMS 50 v - , 10- <br /> POROUS MATERIAL (EXCEPT WOOD) 50 aci N E - o.5 °'o <br /> WOOD 30 0 � o.5o °cv,a <br /> N o C °p ' <br /> FIBERGLASS 80 OO " -.• c L 0'a <br /> N p 0 o L O <br /> 7. PER CALGREEN SECTION 5.504.4.3.2, VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED �' r- ..2 °-° p <br /> w 2 -p 0.5' E U c <br /> AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE o c Ucy o N O <br /> FOLLOWING: ma � L 0 ° N <br /> 1. MANUFACTURER'S PRODUCT SPECIFICATION m ° ~` ° o p <br /> 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS 2 ° � ami `o <br /> N p N c <br /> U ? U <br /> O p <br /> a N p,� U+N+ <br /> 8. PER CALGREEN SECTION 5.504.4.6, RESILIENT FLOORING SYSTEMS SHALL COMPLY WITH THE VOC-EMISSION v o ° 8- a <br /> ,� aN �— <br /> LIMITS DEFINED IN THE 2012 CHPS CRITERIA AND LISTEN ON ITS HIGH PERFORMANCE PRODUCTS DATABASE, o 0 0 , ° a o <br /> PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGAURD CHILDREN & SCHOOLS U <br /> 0 N L O <br /> PROGRAM, CERTIFIED UNDER THE FLOORSCORE PROGRAM OF THE RESILIENT FLOOR COVERING INSTITUTE, OR g'm u�° cc,a� <br /> SHALL MEET CALIFORNIA DEPARTMENT OF PUBLIC HEALTH 2010 SPECIFICATION. Wo o o � o 20.3 o o <br /> o ® v T3 `o Lo <br /> enc <br /> w 5 a <br /> 9. PER CALGREEN SECTION 5.508.1, RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE a U) o L L�, ° <br /> NONHAZARDOUS CONSTRUCTION OR DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.29 OR w a'3 <br /> c-w M <br /> 5.408.1.3 OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS a <br /> MORE STRINGENT. Ztk <br /> bi <br /> rn00 <br /> r w o m o Q w <br /> 10. PER CALGREEN SECTION 5.504.1.3, TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM 00 o 0 o 0 N <br /> w N w Q (n \ O <br /> SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR Z o 0 N <br /> AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL o z - z > � a o <br /> AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN o z o <br /> AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE (n O ci <br /> 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE <br /> ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING <br /> ALTERATION AT THE CONCLUSION OF CONSTRUCTION. Q <br /> U <br /> W <br /> 11. PER CALGREEN SECTION 5.504.3, COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL <br /> EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE <br /> CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT <br /> AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, <br /> SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF <br /> DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. <br /> 12. PER CALGREEN SECTION 5.504.7, ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR <br /> AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR o <br /> INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR 0 O Q z $ <br /> REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY z of _ <br /> AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS 0 Q Dw g <br /> OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR <br /> POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. 0 w o w <br /> LL_ m w Q <br /> ~ W <br /> 0 0 J V <br /> z <br /> LLJ Q <br /> LD w <br /> 0 w N04 <br /> 00 gz w o0 <br /> o0 <br /> w <br /> 0 X w 0 w Ld <br /> L <br /> N W o U) 0 <br /> wOGN1 . 1 <br /> W GENERAL NOTES <br />