My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DANIELS
>
2164
>
1600 - Food Program
>
PR0546307
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2020 4:18:11 PM
Creation date
12/2/2020 4:08:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546307
PE
1614
FACILITY_ID
FA0026229
FACILITY_NAME
SEE'S CANDIES #SF-94
STREET_NUMBER
2164
STREET_NAME
DANIELS
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
2164 DANIELS ST
P_LOCATION
04
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J Ai; <br /> Patrick C. <br /> ia <br /> C-21492 <br /> 9'-4"f 4'-8" EXTERIOR <br /> JAN 31, 2021 , <br /> \ 5Date � <br /> 8 l l \ 8 ;� ' GA � t� <br /> II <br /> I hereby certify that this plan, specification, or report was <br /> DEMOLITION PLAN KEYNOTES prepared by me under my direct supervision and that I <br /> am a duly Registered Architect under the lows of the <br /> jll�� I I I State of CALIFORNIA <br /> OGC TO REMOVE ALL EXISTING FLOORING, ADHESIVES, ETC. AS REQUIRED BACK TO SUBFLOOR. 141 I I~O 13 I Number C21492 Date <br /> GC TO REMOVE ANY UNUSED ELECTRICAL EQUIPMENT, PANELS, CONDUIT, CIRCUITS, ETC. GC TO I 12 LJ_ \ I This drawing is and will remain the property of the <br /> O \ <br /> PROVIDE NEW ELEC/PHONE STUB UP. REFER TO ELECTRICAL PLANS FOR EXTENT OF ELECTRICAL specifically agreed upon purposes, without the prior <br /> WORK, FIELD VERIFY CONDITIONS PRIOR TO BID. �� 10 architects and any reproduction or use for any but the <br /> \ written consent of the architects, is strictly prohibited. <br /> ODIAMOND GRIND EXISTING CONCRETE FLOOR. FILL EXISTING CRACKS AS REQUIRED FOR to 0 I Information contained in these drawings was prepared <br /> I I_�J — I for the specific site listed below. Use of these drawings for <br /> PREPARATION OF NEW FLOORING. I any other location or project is strictly prohibited without <br /> I4 REMOVE EXISTING INTERIOR PARTITION WALL OR INTERIOR FURRING. _ _ _ _ _ _ _ _ — prior written consent of the architects. <br /> O5 REMOVE EXISTING DOOR AND FRAME. I 5 I <br /> OEXISTING STOREFRONT GLAZING, FRAMING AND STOREFRONT DOORS TO BE REMOVED. REFER TO I 4 <br /> 6 SHEETS Al AND A3 FOR NEW STOREFRONT CONFIGURATION AND EXTENTS. <br /> 07 EXISTING DEMISING WALL TO REMAIN. PATCH/REPAIR AS REQUIRED AFTER DEMOLITION. I I <br /> I I <br /> O8 EXISTING EXTERIOR WALL TO REMAIN. PATCH/REPAIR AS REQUIRED AFTER DEMOLITION. <br /> O9 REMOVE EXISTING COUNTERS AND FURNISHINGS. �� I I <br /> I I MBA PROJECT MANAGEMENT, LLC <br /> 10 TRENCH EXISTING CONCRETE FLOOR AS REQUIRED FOR NEW UNDERGROUND PLUMBING. REFER TO I I N5560 CTH ZM, SUITE 3 <br /> PLUMBING PLANS. COORDINATE WITH LANDLORD FOR ALL REQUIREMENTS PRIOR TO START OF <br /> WORK. I I Onalaska, WI. 54650 <br /> O11 EXISTING ELECTRICAL PANEL TO BE REMOVED IF EXISTING IN SPACE. VERIFY CONDITIONS IN FIELD. I ' 608-785-2760 CELL: 507-458-8034 <br /> COORDINATE WITH ELECTRICAL PLANS. I I E—mail: mbapm.tim@gmail.com <br /> 12 REMOVE ANY UNSED EXISTING DRAINS, PIPING, PLUMBING FIXTURES AND ACCESSORIES AND ANY I I <br /> OTHER RELATED PIPING FROM LEASED AREA. VERIFY CONDITIONS IN FIELD. COORDINATE WITH I I <br /> PLUMBING PLANS. <br /> 13 REMOVE PORTION OF EXISTING WALL, EXISTING DOOR AND EXISTING DOOR FRAME AS REQUIRED I I <br /> FOR NEW DOOR OPENING. I I <br /> 14 GC TO REMOVE ALL EXISTING CEILING AND ASSOCIATED SUPPORT SYSTEMS THROUGHOUT LEASED I I CLIENT'S <br /> AREA. VERIFY CONDITIONS IN FIELD. EXCEPT WHERE NOTED OTHERWISE. I I STORE NUMBER SF-94 <br /> REMOVE ALL EXISTING HVAC DIFFUSERS AND UNUSED DUCTWORK FROM LEASED AREA. VERIFY I I <br /> 15 CONDITIONS IN FIELD. COORDINATE WITH MECHANICAL PLANS. <br /> 16 REMOVE ALL EXISTING EXIT/EGRESS LIGHTING FROM LEASED AREA. I I SEE S CANDIES <br /> z <br /> EXISTING SPRINKLER HEADS AND PIPING TO REMAIN THROUGHOUT THE LEASED AREA. GC TO 0 2164 DANIELS STREET <br /> 17 Q I 1 2 3 9 10 11 12 14 15 16 17 I Cf) <br /> Q <br /> CONFIRM SPRINKLER HEADS ARE IN PROPER WORKING ORDER OR REPLACE WITH SAME AS z z z <br /> NECESSARY. GC TO CLEAN/REPAINT TO "LIKE NEW" FINISH. z I THROUGHOUT ENTIRE I g z <br /> I SPACE TYPICAL I o <br /> w Q w <br /> U I I w U <br /> DEMOLITION NOTES Q I I 0 Q MANTECA, CA 95336 <br /> 1. ALL DEMOLITION NOTES ARE INTENDED TO IMPLY THE BASIC PROJECT SCOPE, AND MAY NOT I I C° <br /> BE FULLY INCLUSIVE OF ALL WORK REQUIRED. THE G.C. IS RESPONSIBLE TO FIELD VERIFY I I 9 <br /> ALL EXISTING CONDITIONS PRIOR TO BIDDING. SEE'S CANDIES AND THE ARCHITECT WILL NOT <br /> BE LIABLE FOR OMISSIONS OR VARIATIONS TO BID PLANS. <br /> I I <br /> 2. 50% OF NONHAZARDOUS DEMOLITION MATERIALS SHALL BE RECYCLED. I I <br /> 3. TENANT'S CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE DONE TO LANDLORD PROPERTY <br /> Cz�HIMHEH <br /> DURING BUILD OUT. <br /> 7 3423 S LA. CIENEGA BLVD. <br /> 4. TENANT MUST BARRICADE THE STOREFRONT PER THE LANDLORD'S SPECIFICATIONS. TENANT LOS ANGELES, CA 90016 <br /> MUST USE LANDLORD'S CONTRACTORS FOR BARRICADE CONSTRUCTION AND APPROVED I I PH: 310/287-4616 <br /> GRAPHICS. I I FAX: 310/842-4436 <br /> 5. TENANT CAN NOT REMOVE ANY STRUCTURAL MEMBERS WITHOUT THE REVIEW OF STRUCTURAL I I <br /> ENGINEER AND THE LANDLORD. <br /> SEES CONTACT <br /> RICHARD ESCALANTE <br /> I 310/ 287-4616 <br /> Tim R. Benson <br /> ARCHITECT'S PROJECT MANAGER <br /> I 608/ 785-2760 <br /> L <br /> 0 <br /> I I U L <br /> 0 .- O <br /> NE -0 <br /> date 2 Q ° > comments <br /> I I AS 07/03/200 <br /> I I BUILT <br /> PRELIM 08/03/200 O <br /> REVIEW <br /> I I BID/ 08/10/20 O O O O O <br /> PERMIT <br /> I I <br /> FE- <br /> I I <br /> I I <br /> I I <br /> _ _ drawn by: checked by: <br /> — - - —— — TRB TRB <br /> II � <br /> 8 II � 6 8 THIS SHEET CONTAINS: <br /> IL DEMOLITION PLANS <br /> 20'-72" LEASE DIMENSION <br /> EXTERIOR <br /> r_i_' DEMOLITION FLOOR PLAN <br /> D1 1/4" = V-0" <br /> NORTH <br /> D 1 <br /> ARCHITECT'S COMMISSION NUMBER <br /> 20 - 1010 . 008 <br />
The URL can be used to link to this page
Your browser does not support the video tag.