Laserfiche WebLink
00. ARC <br /> DOOR ELEVATIONS -NOT TO SCALE Patrick C. <br /> 9'-8" 4'-4" <br /> 01 <br /> C-21492 <br /> NOTE: DOOR HARDWARE SHALL BE EASY TO GRASP AND SHALL NOT REQUIRE GRASPING, TIGHT <br /> PINCHING, OR TWISTING OF WRIST. ALL DOORS SHALL HAVE LEVER HARDWARE, PANIC RELEASES, JAN 31, 2021 <br /> OR PUSH-PULL PLATES CENTERED BETWEEN 34-44" A.F.F. ` <br /> 7 1„ <br /> 2'-0"48 3'-52 3 —32 LEASE LINE � ��Dat�r �� ► <br /> 0 C� <br /> 2 <br /> I hereby certify that this plan, specification, or report was <br /> i i � i � prepared by me or under my direct supervision and that I <br /> am a duly Registered Architect under the laws of the <br /> o oW1 V I I State of CALIFORNIA <br /> 00 <br /> I I I a � O 13 Number C21492 <br /> o Date <br /> 1.0 i <br /> (.0 I I I x7100 This drawing is and will remain the property of the <br /> I 3 (V 4 6 1 rr) architects and any reproduction or use for any but the <br /> 7 I specifically agreed upon purposes, without the prior <br /> A / W2 5 13'-104"f 71 , 5'-6" written consent of the architects, is strictly prohibited. <br /> Information contained in these drawings was prepared <br /> I I for the specific site listed below. Use of these drawings for <br /> 6'-0" 4'-0" 3'-0" 3'-0" 3'-6" I B I any other location or project is strictly prohibited without <br /> prior written consent of the architects. <br /> (N.T.S.) (N.T.S.) (N.T.S.) (N.T.S.) (N.T.S.) I I Nr-100 <br /> ELEV. TYPE 1 ELEV. TYPE 2 ELEV. TYPE 3 ELEV. TYPE 4 ELEV. TYPE 5 <br /> WORK ROOM <br /> ENTRY DELIVERY ELIASON RESTROOM SALES TO STOCK AREA i 14 15 I A <br /> ,0 O <br /> LEASE LINE <br /> NOTE: ALL DOOR HEIGHTS ARE TO BE INSTALLED AT FINISHED FLOOR HEIGHT. (6'-8", 7'-0", ETC.) I RESTROOM 1 <br /> NO EXCEPTIONS I C <br /> A>* - <br /> 10 11 I o <br /> I <br /> I I O A&�� <br /> I 1 MBA PROJECT MANAGEMENT, LLC <br /> DOOR DESCRIPTION I I N5560 CTH ZM, SUITE 3 <br /> NEW (PR)3'-O"X 7'-0" DOORS. G.C. TO PROVIDE: GRID INSERTS AND SIGNAGE SUPPLIED & INSTALLED BY GC. G.C. SHALL PROVIDE THE FOLLOWING: NEW I 1 Onalaska, WI. 54650 <br /> O THRESHOLD, WEATHERSTRIPPING, CONCEALED SWEEPS, BLACK OFFSET RADIUS "C" HANDLES (BOTH IN AND OUT), JACKSON OVERHEAD FULLY CONCEALED I I 608-785-2760 CELL: 507-458-8034 <br /> CLOSER W/ NON HOLD OPEN 90', DOUBLE ACTING PIVOT HINGE SQUARE GLASS STOPS, BOTH LEAFS TO RELEASE WITH ONE MOTION PER CODE. G.C. I � I _ E—mail: mbapm.tim@gmail.com <br /> SHALL PROVIDE SIGN STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUSINESS IS OCCUPIED" IN 1" LETTERS WITH CONTRASTING BACKGROUND. SEE r-100 <br /> DOOR DETAILS 4/A7 & 5/A7. I I <br /> I 1 <br /> AB A <br /> ONEW 3'-6"X 7'-0" METAL DOOR SUPPLIED AND INSTALLED BY G.C. G.C. SHALL PROVIDE THE FOLLOWING: NEW THRESHOLD, SMOKE GASKET, CONCEALED I 20'-0"f 14 <br /> SWEEP, JACKSON OVERHEAD FULLY CONCEALED CLOSER W/ NON HOLD OPEN 90', AND PANIC HARDWARE AS REQUIRED TO ALARM LOCK SET BY <br /> ALARM SYSTEMS #250X28 W/ RIM CYLINDER CERKA-12345. I1» 1» 1 <br /> I 4 _3» 3>_6» 7'-12 f 3 —02 2'-1" I <br /> ONEW 3'-0" x 6'-8" "ELIASON" BRAND, MODEL LWP6 SELF-CLOSING, DOUBLE 6" X 30" DOOR WITH PLASTIC LAMINATE (WHITE) FINISH BOTH -I10' I CLIENT'S <br /> SIDES AND ACRYLIC WINDOW IN BLACK RUBBER MOLDING. VIEW PANEL MUST BE MIN. 200 SQ. IN. AND 1 <br /> WHITE CERAMIC PULLS (SUPPLY & 14 i STORE NUMBER SF-94 <br /> INSTALLED BY G.C.), NO LATCH. (NOTE: THIS DOOR IS JAMBLESS). DOOR SUPPLIED & INSTALLED BY G.C. REFER TO <br /> SPEC. 9, SHEET SP3, AND SHEET A6. NO SUBSTITUTIONS. 14 <br /> NEW _ _ DOOR AND _ O B <br /> O SCHLAGEO"DX SERFS ^LE ER D00 D ENWITH APUSHP OFFICE LLOCK. RE ERM TO SPEC.C9 TSHEETOVSP3. 1 1/2 PR HINGES, NORTON 1601 BF CLOSER, S EES CANDIES <br /> I 1 <br /> I IONEW 3'-6" X 6'-8" METAL DOOR & 3-PIECE KNOCK DOWN METAL FRAME BY G.C., PAINT W-1. NORTON 1601 BF CLOSER, KICK DOWN DOOR I it it � I z 2164 DANIELS STREET <br /> STOP. PAINT BOTTOM 6" W-2 SALES SIDE. PROVIDE PEEP HOLE AT 60" A.F.F. REFER TO SPEC. 9, SHEET SP3. KEYLESS ENTRY LOCKSET. O <br /> I i I I 1 w <br /> I I g <br /> I I o <br /> i I I <br /> I I w <br /> NOTES: -ALL DOORS WITH EXPOSED DOOR CLOSERS TO HAVE NORTON 1601BF DOOR CLOSERS I 1 Cf) <br /> -REFER TO SPEC. SHEET SP2, DIVISION 8 FOR ADDITIONAL DOOR AND HARDWARE INFORMATION. I 1 w M A N T E CA, CA 95336 <br /> DOOR QTY. ELEV. DOOR SPECIAL <br /> MARK REQ'D TYPE SIZE REQ'D NOTES 00 <br /> I i I i 1 I <br /> 1 1 1 (PR)3'-O" X 7'-0" COORDINATE DOOR INSTALLATION WITH SEE'S PROJECT MANAGER. I 1 9 <br /> O 1 2 3'-6" X 7'-0" PROVIDE/INSTALL CLOSER AND ALARM LOCK SET BY ALARM SYSTEMS #250X28 W/ RIM <br /> CYLINDER CERKA-12345. <br /> I I i i 1 <br /> 3 3'-0" X 6'-8" SUPPLIED & INSTALLED BY G.C. Cz�HIMHEH <br /> O4 1 4 3'-0" X 6'-8" INSTALL CLOSER AS REQUIRED, ADD TOILET ROOM SIGNAGE PER SHEET CS. I --�2�►I 1 <br /> 0 1 5 3'-6" X 6'-8" KEYLESS ENTRY - SIMPLEX MECHANICAL DOOR LOCK #5021-XS-WL-26D-41 BY G.C. I 1 3423 S LA. CIENEGA BLVD. <br /> LOS ANGELES, CA 90016 <br /> J I PH: 310/287-4616 <br /> SALES AREA 1 FAX: 310/842-4436 <br /> WALL TYPE SCHEDULE REFER TO SPEC SHEETS I 10 1 SEE'S CONTACT <br /> CD RICHARD ESCALANTE <br /> A (EXISTING) B NEW C NEW I I 310/ 287-4616 <br /> r� <br /> I I <br /> Tim R. Benson <br /> LEASE LINE ARCHITECTS PROJECT MANAGER <br /> L EXISTING DEMISING WALL INTERIOR PARTITION INTERIOR PARTITION I 1 608/ 785-2760 <br /> GC TO EXTEND GYP. BD. SEE DESCRIPTION BELOW SEE DESCRIPTION BELOW & I I L <br /> TO CEILING AND INSULATE -0& DET. 13/A6 DET. 3/A5 (6" MTL. STUDS <br /> IF NOT EXISTING IN LIEU OF 3 5/8") I 1 L_ � a L <br /> I I � <br /> 0 .— 0 <br /> � � E � -0 <br /> INTERIOR PARTITION: 3 5/8" X 20 GA. MTL. STUDS © 16" O.C. WITH 5/8" TYPE 'X' GYP. BD. BOTH SIDES. TAPED, SPACKLED, SANDED & PAINTED. A I I date ° Q o > comments <br /> PARTITION HGT. © LAY-IN CLG'S TO 6" ABOVE HIGHEST CEILING LEVEL; © GYP. BD. CLG'S, STUDS SHALL EXTEND TO JOISTS EVERY 4'-0" (SEE DETAIL). <br /> NOTE: ® TOILET & WET AREAS PROVIDE MOISTURE RESISTANT (GREEN BOARD) GYP. BD., G.C. TO PROVIDE 16 GA. METAL STUDS AT WATER HEATER. WALLS AS BUILT 07/03/20 O <br /> TO BE LATERALLY BRACED WITH 3 5/8" METAL STUDS AT 48" O.C. <br /> NOTE: INSULATE ALL WALLS FOR SOUND INSULATION I I PRELIM 08 03 200 O <br /> REVIEW / / <br /> I <br /> • THE G.C. IS RESPONSIBLE TO FIELD VERIFY ALL TENANT DEMISING I 1 BID/ 08/10/20 O O O O O <br /> WALLS ARE DRYWALLED TO THE DECK IF NOT ALREADY EXISTING. PERMIT <br /> FLOOR PLAN KEY NOTES MAXIMUM THRESHOLD AND TRANSITION SHALL <br /> A <br /> I i BE 1/2" MAX AT ENTRY DOOR. CHANGE IN 1 <br /> I J LEVEL BETWEEN 1/4" AND 1/2" SHALL BE 1 <br /> BEVELED WITH A SLOPE NO GREATER THAN <br /> 1 ELECTRICAL PANEL LOCATION, REFER TO ELECTRICAL PLANS. 1 UNIT VERTICAL TO 2 UNITS HORIZONTAL. <br /> 8 GC TO PROVIDE HEAVY DUTY THRESHOLD ABLE <br /> 2 LINE REPRESENTS EDGE OF CABINETRY. I TO SUPPORT HEAVY DELIVERIES ON A PALLET 1 <br /> JACK. 1 <br /> 3 PROVIDE NEW MOP SINK. REFER TO SHEET A5 FOR DETAILS. COORDINATE WITH PLUMBING DRAWINGS. <br /> drawn by: checked by: <br /> O NEW 3—COMPARTMENT STAINLESS STEEL SINK, REFER TO PLUMBING DRAWINGS. TRB TRB <br /> 0@ <br /> OPROVIDE NEW WATER HEATER ABOVE MOP SINK. REFER TO SHEET A5 FOR DETAILS. COORDINATE WITH PLUMBING DRAWINGS. THIS SHEET CONTAINS: <br /> O NEW HANDSINK, REFER TO PLUMBING PLANS. 8 LEASE LINE 8 8 <br /> FLOOR PLAN <br /> G.C. TO PROVIDE 5/8" FIRE TREATED PLYWOOD IN PLACE OF GYP. BOARD BEHIND MANAGERS DESK, FLOOR TO 8'-0". 3'-2" 6'-4" 3'-2" 3'-2" WALL TYPES <br /> 7 DOOR SCHEDULE AND NOTES <br /> 8 EXISTING EXTERIOR STOREFRONT WALL TO REMAIN. PROVIDE NEW STOREFRONT DOORS, STOREFRONT GLAZING AND FRAMING AS REQUIRED. SUPPLIED & <br /> INSTALLED BY G.0 VERIFY ALL MIN. ENERGY COMPLIANCE IS MET. REFER TO ENERGY REQUIREMENTS ON SHEET T-1. REFER TO EXTERIOR ELEVATION, SHEET 2'_38» 16'-0" 2 —38» <br /> A3, FOR NEW FINISHES AND NEW STOREFRONT CONFIGURATION. <br /> OEXISTING ENTRY DOORS TO REMAIN. PROVIDE NEW LATTICE IF REQUIRED — SEE DETAILS 4/A7 & 5/A7. 20'-72" LEASE DIMENSION <br /> 10 G.C. IS TO INFILL / REPAIR CONCRETE FLOOR AS REQUIRED FOR NEW UNDERGROUND PLUMBING. REFER TO PLUMBING PLANS. COORDINATE WITH 70, <br /> LANDLORD FOR ALL REQUIREMENTS PRIOR TO START OF WORK. G.C. TO INSTALL NEW VAPOR BARRIER AT ALL DEMO'D FLOORING AREA. NEW CONCRETE l <br /> TO BE DOWELED IN TO EXISTING W/ #4 REBAR O 18" O.C. W/ 4" EPDXYED EMBED. A3 <br /> 1 1 PROVIDE AND INSTALL NEW RESTROOM FIXTURES AND ACCESSORIES. VERIFY ALL FIXTURES COMPLY WITH ACCESSIBILITY REQUIREMENTS. REFER TO l FL00 R PLAN <br /> CODE SHEET CS. COORD. WITH PLUMBING SHEETS. Al 1/4" = V-0" <br /> 12 EXISTING EXTERIOR WALL TO REMAIN. SEE DEMOLITION SHEET D1, EXTERIOR ELEVATION SHEET A3. NORTH <br /> 13 PROVIDE INFILL TO MATCH EXISTING ADJACENT CONSTRUCTION AS REQUIRED. FLOOR PLAN NOTES <br /> 14 PROVIDE PLYWD. BACKING FROM 5-6" TO 7'-6" A.F.F. FOR WALL SHELVING ABOVE (TYP). NOTE TO G.C.: <br /> PROVIDE PLYWD. FULL LENGTH OF EQUIPMENT THIS AREA. SEE SHEET A2 FOR FIXTURE LOCATIONS AND FIELD VERIFY EXACT LOCATIONS PRIOR TO 1. FIELD VERIFY EXISTING CONCRETE SLAB CONDITIONS AT ENTRY PRIOR <br /> Al <br /> 15 INSTALLATION OF EQUIPMENT/PLYWOOD. TO BIDDING. MODIFY / REMOVE SLAB AS REQUIRED FOR A FLUSH <br /> TRANSITION TO EXISTING EXTERIOR COMMONS AREA. <br /> 2. ALL FLOOR TRANSITIONS TO BE FLUSH, 1/2" MAXIMUM HIGH <br /> THRESHOLD AT ALL DOORS. ARCHITECT'S COMMISSION NUMBER <br /> 3. SEE SHEETS A2.1 AND A4 FOR FINISH SCHEDULE. 20 - 1010 . 008 <br />