My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082950
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SUGAR
>
9375
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0082950
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/24/2020 2:50:30 PM
Creation date
12/3/2020 2:22:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0082950
PE
4201
STREET_NUMBER
9375
Direction
N
STREET_NAME
SUGAR
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21216017
ENTERED_DATE
12/2/2020 12:00:00 AM
SITE_LOCATION
9375 N SUGAR RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\fgarciaruiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Access risers (indicated as 24"for septic tanks, 30"for surge/dosing tank)inadequate <br /> for physical entry;normally minimum 36 to 48 inches with ladder required for entry. <br /> The above operational issues should be addressed or the design modified to eliminate the <br /> anticipated risks and problems. The rational for proposing such deep tanks and sewer lines is <br /> unclear. <br /> 3. Problematic Effluent Sewer Design.The effluent sewer design which incorporates a dozen <br /> or more conventional sewer manholes is problematic and contrary to industry practice for <br /> effluent sewer systems conveying septic tank effluent. Sewer manholes are unnecessary since <br /> the sewage solids are retained in the septic tanks. More importantly, concrete manholes (not <br /> vented)will rapidly deteriorate from the corrosive gases given off by the anaerobic septic <br /> tank effluent passing though the pipes. They will be a constant source of nuisance odors— <br /> and also a potential safety issue due to collection of hazardous gases. Conveyance of septic <br /> tank effluent from septic tanks to the surge/dosing tank should be via fully sealed piping. The <br /> only access to the pipes (e.g., for flushing)should be through capped clean-outs installed at <br /> various points in the collection system. Also, for the deep sewer line depth proposed,the <br /> manholes will introduce additional points of entry for groundwater infiltration into the <br /> wastewater system, which has very limited capacity for extraneous water. <br /> 4. Filter Bed Drain Rock Depth. Detail 9 ("Leach Field Line")on Sheet C7.3 indicates an 8- <br /> inch depth of drain rock below the 4"perforated pipe; 12 inches is required. <br /> APPENDIX A—NITRATE LOADING STUDY(Chesney Consulting, dated May 6,2019) <br /> The appended Nitrate Loading Study by Chesney Consulting utilizes an annual chemical-water <br /> mass balance analysis (per Hantzsche-Finnemore Equation)to estimate the nitrogen loading <br /> impact on groundwater from onsite disposal of wastewater for the E&E Trading project. <br /> The analysis projects a resultant percolate concentration of 1.55 mg-N/L reaching the <br /> groundwater table, averaged over the 42-acre footprint of the E&E Trading project site. This is <br /> compared against the drinking water nitrate-nitrogen standard of 10 mg-N/L to conclude that the <br /> discharge is within appropriate limits and will not significantly degrade groundwater quality. <br /> Comments: <br /> 1. Methodology. The mass balance analysis per the Hantzsche-Finnemore Equation is a <br /> simplified method for assessing wastewater-nitrogen loading for typical rural residential <br /> properties served by septic systems. It doesn't explicitly account for large amounts of <br /> impervious surface,nor drainage retention facilities, as proposed for this proposed project. <br /> The improvement plans indicate nearly the entire site will be covered with buildings and <br /> paving, leaving very limited amount of open land area for deep percolation/recharge. The <br /> rainfall-runoff from impervious surfaces is planned to be collected and routed to an adjacent <br /> detention/retention basin for percolation and downstream discharge. The concept and <br /> 3 <br />