Laserfiche WebLink
PLUMBING LEGEND <br />SYMBOL <br />DESCRIPTION <br />WASTE <br />SOIL, WASTE OR SANITARY SEWER BELOW GRADE OR SLAB <br />GW <br />GREASE WASTE BELOW GRADE <br />AW <br />ACID WASTE <br />CW <br />SOIL, WASTE OR SANITARY SEWER ABOVE GRADE OR SLAB <br />- - - - - - <br />VENT PIPING <br />- <br />COLD WATER PIPING <br />- - <br />HOT WATER PIPING <br />--- <br />HOT WATER RETURN PIPING <br />T <br />TEMPERED WATER PIPING <br />F <br />FILTERED WATER PIPING <br />G <br />GAS PIPING - PRESSURE NOTED <br />CA <br />COMPRESSED AIR PIPING <br />FS <br />FIRE SPRINKLER PIPING <br />SD <br />STORM DRAIN PIPING <br />P4TR <br />PRESSURE AND TEMPERATURE RELIEF PIPING <br />CD <br />CONDENSATE DRAIN PIPING <br />' <br />EXISTING PIPING OR FIXTURE TO BE REMOVED OR ABANDONED IN PLACE <br />--111--- <br />UNION <br />-Df3--- , SOV <br />SHUT OFF VALVE <br />tea- <4 GV <br />GATE VALVE <br />___0_ GV/VB <br />GATE VALVE IN VALVE BOX <br />-}- CKV <br />CHECK VALVE - DIRECTION OF FLOW INDICATED <br />--i�--- BV <br />BALL VALVE <br />C> <br />AUTOMATIC GAS SHUT-OFF VALVE <br />P4TRV <br />PRESSURE AND TEMPERATURE RELIEF VALVE <br />-� GCO, FCO <br />GRADE CLEAN OUT, FLOOR CLEAN OUT <br />�t-- CO, WCO <br />CLEANOUT, WALL CLEANOUT <br />-® FD <br />FLOOR DRAIN <br />�-- FS <br />FLOOR SINK <br />-+ HB <br />HOSE BIBS <br />-+- -�}- POC <br />POINT OF CONNECTION <br />I.E. <br />INVERT ELEVATION <br />FF. <br />FINISHED FLOOR <br />/FT <br />PER FOOT <br />US,UF,UG <br />UNDER SLAB, UNDER FLOOR, UNDERGROUND <br />FA, TA <br />FROM ABOVE, TO ABOVE <br />FB, TB <br />FROM BELOW, TO BELOW <br />TYP. <br />TYPICAL <br />(N) <br />NEW <br />(E), EXISTING <br />EXISTING TO BE FIELD VERIFIED BY CONTRACTOR <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />ABC <br />ABOVE CEILING <br />CI <br />CAST IRON <br />VCP <br />VITRIFIED CLAY PIPE <br />V, VR, VTR <br />VENT, VENT RISER, VENT THRU ROOF <br />A WD <br />WASTE, WASTE DROP <br />HW, HWD, HWR <br />HOT WATER, HOT WATER DROP, HOT WATER RISER <br />CW, CWD, GWR <br />COLD WATER, COLD WATER DROP, COLD WATER RISER <br />TDL <br />TOTAL DEVELOPED LENGTH <br />FIXTURE CONNECTION SCHEDULE <br />SYMBOL FIXTURE DESCRIPTION <br />VENT <br />WASTE <br />WATER <br />0 <br />GAS <br />DIRECT <br />IIID. <br />CW <br />HW <br />BTUH <br />WC <br />WATER CLOSET, FV <br />2 <br />3 <br />- <br />11/4 <br />- <br />- <br />L <br />LAVATORY <br />11/z <br />2 <br />1-114" <br />3/4 <br />3/4 <br />- <br />MS <br />MOP SINK <br />11/2 <br />2 <br />- <br />1/2 <br />1/2 <br />6.3 <br />FD/FS <br />2" FLOOR DRAIN/SINK <br />2 <br />2 <br />- <br />- <br />72.5 <br />7.5 <br />FD/FS <br />3" FLOOR DRAIN/SINK <br />2 <br />3 <br />- <br />- <br />- <br />- <br />13 <br />3 -COMPARTMENT SINK <br />DIRECT CPG 104.3 <br />JOINT. <br />BFP <br />14 <br />DISHWASHER <br />BEVERAGE MACHINES, COFFEE MACHINE, TEA BREWER AND ESPRESSO <br />- <br />11/2 <br />- <br />3/4 <br />- <br />15 <br />HOT FOOD WELL <br />- <br />- <br />3/4 <br />1/2 <br />- <br />- <br />IS <br />SODA STATION <br />- <br />- <br />3/4 <br />1/2 <br />- <br />- <br />19 <br />COFFEE MAKER <br />- <br />- <br />3/4 <br />1/2 <br />- <br />- <br />NO. <br />HAND SINK <br />11/2 <br />2 <br />- <br />'/2 <br />I/2 <br />- <br />21 <br />ICE MACHINE <br />- <br />- <br />3/4 <br />I/2 <br />- <br />_ <br />22 <br />PREP SINK <br />TOTAL <br />FU <br />3 -COMPARTMENT SINK <br />1 <br />3 <br />3 <br />GENERAL PLUMBING NOTES <br />1. ALL EQUIPMENT AND MATERIALS USED SHALL BE NEW AND SHALL <br />BE EQUAL IN QUALITY, TYPE, CAPACITY AND ACCESSORIES TO THE <br />EQUIPMENT NOTED ON THE DRAWINGS. ADJUSTMENTS TO <br />CONSTRUCTION AND ACCESSORIES ON SUBSTITUTED EQUIPMENT <br />MAY BE REQUIRED TO ACHIEVE THIS EQUALITY, AND SHALL BE <br />INCLUDED AT NO EXTRA COST TO THE OWNER MAKE ANY CHANGES <br />IN PIPING, FRAMING, ETC., AS REQUIRED TO ACCOMMODATE <br />SUBSTITUTED EQUIPMENT. <br />2, INSTALL ALL EQUIPMENT AND MATERIALS AND PERFORM ALL WORK <br />IN ACCORDANCE WITH ALL APPLICABLE CODES. APPLICABLE <br />CODES SHALL INCLUDE, BUT NOT BE LIMITED TO THE LATEST <br />EDITIONS OF THE UNIFORM MECHANICAL CODE FOR THE STATE OF <br />CALIFORNIA, UNIFORM PLUMBING CODE FOR THE STATE OF <br />CALIFORNIA, CALIFORNIA CODE OF REGULATIONS (CCR), UNIFORM <br />FIRE REGULATIONS AND TITLE 24 ENERGY EFFICIENCY STANDARDS. <br />WHERE HEAVIER GAGES OF MATERIAL, LARGER SIZES OR MOR_ <br />STRINGENT REQUIREMENTS THAN THE CODES ARE REQUIRED BY THE <br />CONTRACT DOCUMENTS, SUCH INCREASED REQUIREMENTS SHALL <br />APPLY. <br />3, PIPING MATERIALS SHALL BE AS FOLLOWS: <br />WASTE AND VENT SHALL BE SCHEDULE Ofd PVC. <br />POLYVINYL CHLORIDE (PVC) PLASTIC PIPE. ALL <br />PIPE, COUPLINGS AND FITTINGS SHALL BE MANUFACTURED OF <br />MATERIAL CONFORMING TO ASTM D 1185. PLASTIC SOLVENT CEMENT <br />FOR PVC PLASTIC PIPE SHALL CONFROM TO ASTM D 2235. <br />ACID RESISTANT WASTE AND VENT SHALL BE SCHEDULE 40 PVC. <br />POLYVINYL CHLORIDE (PVC) PLASTIC PIPE. ALL <br />PIPE, COUPLINGS AND FITTINGS SHALL BE MANUFACTURED OF <br />MATERIAL CONFORMING TO ASTM D 1185. PLASTIC SOLVENT CEMENT <br />FOR PVC PLASTIC PIPE SHALL CONFROM TO ASTM D 2235. <br />CONDENSATE DRAIN PIPING: TYPE DWV COPPER TUBING AND <br />FITTINGS OR SCHEDULE 40 GALVANIZED STEEL PIPE AND <br />MALLEABLE IRON FITTINGS. (PVC PIPING WILL NOT BE <br />ACCEPTABLE.) <br />WATER PIPE (HOT AND COLD WATER): TYPE L BELOW GRADE, <br />TYPE M ABOVE GRADE, COPPER TUBING, HARD -TEMPER, WITH <br />WROUGHT COPPER FITTINGS. SOLDERING / BRAZING MATERIAL <br />SHALL BE LEAD FREE, SILVER SOLDER BELOW GRADE, 95-5 OR <br />SIMILAR ABOVE GRADE. CAPPED OR PLUGGED OUTLETS SHALL BE <br />SCHEDULE 40 SCREWED BRASS. ELBOWS AT BRANCH OUTLETS <br />SHALL BE SCREWED OUTLET, WITH EARS, FOR NAILING OR SCREWING <br />TO WALL BACKING. <br />GAS PIPING: PIPING SHALL BE BLACK STEEL, STM A-53, WITH <br />MALEABLE STEEL FITTINGS. PIPE SIZES 3" AND OVER SHALL <br />HAVE WELDED JOINTSt SIZES 2-1/2" AND SMALLER MAY BE THREADED <br />OR MELDED, AT CONTRACTOR'S OPTION, EXCEPT THAT ,ALL PIPING <br />UNDERGROUND SHALL BE WELDED, REGARDLESS OF SIZE. <br />4. PIPING AND EQUIPMENT ACCESSORIES SHALL BE AS FOLLOWS: <br />PROVIDE STOPS FOR ALL FIXTURES. STOPS SHALL HAVE <br />THREADED INLETS, SIMILAR TO SPEEDWAY SR 3112. STOPS WITH <br />BRAZED (SOLDERED) OR COMPRESSION INLET CONNECTIONS WILL <br />NOT BE ALLOWED. <br />PROVIDE ELBOWS AT ALL PIPING PENETRATIONS OF WALLS TO <br />STOPS. ELBOWS SHALL HAVE NAILING EARS, AND SHALL BE <br />SECURELY FASTENED TO THE STRUCTURE. NIPPLES THROUGH THE <br />WALLS SHALL BE IPS WEIGHT THREADED COPPER OR BRASS. <br />PROVIDE TRAPS FOR ALL FIXTURES. TRAPS FOR SINKS AND LAV$ <br />SHALL BE BRASS, 11 GAGE MINIMUM THICKNESS, WITH INTEGRAL <br />CLEANOUT <br />PROVIDE CHROME PLATED ESCUTCHEON PLATES ON ALL PIPES <br />PASSING THROUGH WALLS OR CEILINGS. ALL EXPOSED PIPING <br />SHALL BE CHROME PLATED. <br />PROVIDE PERMANENT CLEVIS TYPE HANGERS FOR ALL PIPING. <br />WIRE, ROPE, WOOD BLOCKING OR PERFORATED METAL TAPE WILL <br />NOT BE ACCEPTED. PROVIDE PLASTIC WRAPPING OF PIPE WHERE <br />DISSIMILAR METALS OCCUR SUCH AS BETWEEN COPPER AND IRON <br />PIPING AND SUPPORTS. <br />PROVIDE WRAP ON WASTE, HOT AND COLD WATER PIPING UNDER <br />ADA ACCESSIBLE PLUMBING FIXTURES. PLUMBEREX <br />"PRO -EXTREME" ONE-PIECE PROTECTOR WITH FULL ROTATION <br />OPTION, AND 3-M DUAL LOCK FASTENERS SECURED WITH SELF <br />LOCKING NYLON STRAPS. <br />5. CATHODIC PROTECTION: <br />WRAP ALL COPPER OR STEEL WATER PIPING UNDER FLOOR OR <br />BELOW GRADE WITH TWO LAYERS OF PABCO-WRAP, OR SIMILAR <br />MATERIALS, INCLUDING ALL JOINTS. GAS PIPING BELOW GRADE <br />SHALL BE WRAPPED AS DESCRIBED FOR WATER PIPING, OR, AT <br />CONTRACTOR'S OPTION, MAY HAVE EXTRU-COAT OR SIMILAR <br />COVERING. ALL FIELD JOINTS SHALL BE WRAPPED AS FOR BARE <br />PIPING JOINTS. PLACE EXTRU-COAT GAS PIPING IN A SAND OR <br />SIEVED EARTH BED, WITH SIMILAR COVERING TO A LEVEL OF 4" <br />ABOVE TOP OF PIPE. <br />WRAP WATER, WASTE AND GAS PIPING THROUGH THE FLOOR SLAB <br />WITH I/2" THICK FIBERGLASS, 2" ABOVE _Ahl=� <br />SURFACES. <br />GENERAL PLUMBING NOTES (cont.) <br />1. INSTALLATION: <br />INSTALL ALL PIPING IN ACCORDANCE WITH THE UNIFORM PLUMBING <br />CODE WITH THE STATE OF CALIFORNIA AMENDMENTS. SLOPE ALL <br />WASTE PIPING AS INDICATED ON THE DRAWINGS, AND ALL WATER <br />PIPING TO INSURE ELIMINATION OF AIR CAREFULLY GRADE ALL <br />WASTE PIPING TO ENSURE A UNIFORM SLOPE IS ACHIEVED, WITHOUT <br />ANY DIPS OR HIGH POINTS IN THE PIPING. <br />CAREFULLY TRENCH FOR ALL UNDERGROUND PIPING, AVOID OTHER <br />UTILITIES, AND REPAIR ANY DAMAGES TO SAME CAUSED BY THE <br />WORK OF THIS CONTRACT. PROVIDE PROPER SHORING FOR ALL <br />DEEP TRENCHES, AS REQUIRED BY THE SAFETY REGULATIONS OF <br />THE STATE OF CALIFORNIA, AND BY OSHA. PROVIDE ALL REQUIRED <br />BARRICADES, WARNING SIGNS, ETC. CAP ALL PIPING ENDS AT THE <br />CLOSE OF THE DAY'S WORK TO PREVENT ENTRY OF FOREIGN <br />MATERIALS. FLUSH PIPING OF ALL DEBRIS BEFORE CONNECTING TO <br />FIXTURES. <br />EMBED ALL UNDERGROUND PIPING, OTHER THAN GAS PIPING, IN <br />SIEVED EARTH FOR A DEPTH OF 4" ABOVE THE PIPE. SMOOTH THE <br />TRENCHING BELOW THE PIPING FREE FROM ANY ROCKS OR SIMILAR <br />OBSTRUCTIONS, AND PROVIDE SPACE FOR BELLS OR MECHANICAL <br />JOINTS FOR ALL WASTE PIPING. LATERALLY BRACE PIPING TO <br />PREVENT PIPE MOTION DURING BACK FILLING OPERATIONS. <br />PROVIDE SHOCK ABSORBERS AT HOT AND COLD WATER AT ALL <br />FIXTURES. ABSORBER SHALL BE A LINE SIZE PIPE RISER <br />CONNECTING TO A 12" HIGH CAPPED PIPE CHAMBER SIZED ONE <br />SIZE LARGER THAN THE RISER A SINGLE MECHANICAL SHOCK <br />ABSORBER MAY BE UTILIZED FOR A BATTERY OF FIXTURES, <br />PROVIDED THE ABSORBER IS SIZED FOR THE MAIN LINE SERVING <br />THE BATTERY OF FIXTURES. <br />CHLORINATE ALL WATER PIPING FOR A PERIOD OF 8 HOURS, BY <br />CHARGING WITH A CHLORINE OR HYPO CHLORITE SOLUTION TO <br />ACHIEVE A 5 PPM STRENGTH AT THE FIXTURE FURTHEST FROM THE <br />POINT OF APPLICATION. UPON COMPLETION OF CHLORINATION, <br />FLUSH ALL PIPING UNTIL NO CHLORINE CAN BE DETECTED BY <br />TASTE. <br />AFTER CHLORINATION AND ALL TESTING HAS BEEN COMPLETED, <br />CLEAN ALL FIXTURE STRAINERS, AND SET WATER FLOWS FROM <br />FIXTURES IN ACCORDANCE WITH THE REQUIREMENTS OF T24, CCR <br />8, TESTS: <br />TEST ALL GAS PIPING FOR A PERIOD NOT LESS THAN TWO HOURS <br />AT A PRESSURE OF NOT LESS THAN 10 PSIG, USING SOAP AND <br />WATER OR SIMILAR MATERIALS AT ALL JOINTS. WELDED GAS PIPING <br />SHALL BE TESTED PER UPC/GPC. <br />TEST ALL WASTE AND VENT PIPING FOR A PERIOD OF NOT LESS <br />THAN 8 HOURS BY CAPPING OR PLUGGING ALL JOINTS TO A LEVEL <br />OF THE HIGHEST FIXTURE OR FITTING, FILLING THE SYSTEM WITH <br />WATER AND OBSERVING FOR LEAKS, TEST UNDERGROUND SECTION <br />OF PIPE WITH A RISER TO ACHIEVE THE PRESSURE EQUIVALENT TO <br />THE HIGHEST FIXTURE OR FITTING. <br />TEST WATER PIPING AT 100 PSIG FOR A PERIOD OF EIGHT HOURS, <br />OBSERVING FOR ANY VISIBLE LEAKS. TEST PIPING AGAIN WITH <br />FIXTURES INSTALLED AT 60 PSIG. <br />REPAIR ANY LEAKS FOUND BY REMAKING THE JOINT. DO NOT USE <br />CAULKING OR SIMILAR METHODS TO CORRECT LEAKS. UPON <br />REPAIRING ANY LEAKS FOUND, AGAIN TEST THAT PORTION OF THE <br />SYSTEM AS DESCRIBED ABOVE. <br />g. PROVIDE SIX COPIES OF SUBMITTALS WITH MFR'S OPERATING AND <br />MAINTENANCE DATA FOR ALL ITEMS OF EQUIPMENT INSTALLED. <br />INDICATE THE EXACT MODEL($) OF EQUIPMENT, WHERE THE <br />MANUFACTURER'S DATA INCLUDES MODELS OTHER THAN THOSE <br />INSTALLED. BIND THE INFORMATION IN 3 RING BINDERS, WITH <br />DIFFERENT TYPES OF EQUIPMENT INDEXED. PROVIDE A SHEET <br />INDICATING THE CONTRACTOR'S (AND SUBCONTRACTOR'S) NAMES, <br />ADDRESSES AND TELEPHONE NUMBERS. INCLUDE ALSO THE <br />PREFERRED SOURCE$ OF SPARE PARTS FOR THE EQUIPMENT <br />INSTALLED, INCLUDING ADDRESSES, TELEPHONE NUMBERS, ETC. <br />10, CONTRACTOR SHALL VERIFY ALL WORK CONDITIONS, PRIOR TO <br />COMMENCING WORK, INCLUDING, BUT NOT LIMITED TO: PIPING SIZES, <br />INVERT ELEVATIONS, POINTS OF CONNECTION, FIXTURES AND <br />EQUIPMENT, STRUCTURAL ELEMENTS AND MATERIALS INDICATED AS <br />EXISTING, AS WELL AS THE COORDINATED INSTALLATION OF ALL <br />NEW WORK MATERIALS, EQUIPMENT, ETC. VERIFY THE LOCATION AND <br />REQUIRED PIPING CONNECTIONS OF ALL HVAC OR OTHER <br />MECHANICAL EQUIPMENT. NOTIFY ARCHITECT OF ANY <br />DISCREPANCIES PRIOR TO TRENCHING OR COMMENCING OTHER <br />WORK. <br />11. ROUTE CONDENSATE PIPING FROM EQUIPMENT TO NEAREST <br />APPROVED RECEPTOR ALL CONDENSATE SYSTEMS SHALL <br />TERMINATE INTO THE STORM DRAINAGE SYSTEM, UNLESS NOTED <br />OTHERWISE, AND SHALL OTHERWISE BE INSTALLED IN ACCORDANCE <br />WITH ALL APPLICABLE LOCAL AND STATE CODES. CONNECT TO <br />EQUIPMENT COMPLETE WITH VENTED P -TRAP. <br />12. MECHANICAL EQUIPMENT AND IDENTIFICATION TAGS SHOWN ON <br />DRAWING ARE FOR THE COORDINATION OF UTILITIES ONLY, REFER <br />TO MECHANICAL DRAWINGS FOR EQUIPMENT SPECIFICATIONS. <br />WATER PIPE SIZING CHART <br />PIPE SUES CALCULATED BASED ON UPC/CPC APPENDD( A <br />1/2" <br />0.545 <br />2.4 <br />3.3 <br />2 <br />0 <br />2.4 3.3 <br />2 <br />314" <br />0.785 <br />6.3 <br />4.2 <br />7 <br />0 <br />6.3 4.2 <br />7 <br />1"" <br />1.025 <br />12.8 <br />5.0 <br />16 <br />0 <br />12.8 5.0 <br />16 <br />1-114" <br />1.265 <br />22.2 <br />5.7 <br />34 <br />5 <br />19.6 5.0 <br />28 <br />1-V2" <br />1.505 <br />35.0 <br />6.3 <br />66 <br />20 <br />27.7 5.0 <br />46 <br />Z. <br />1.985 <br />72.5 <br />7.5 <br />236 <br />116 <br />48.2 5.0 <br />119 <br />PLUMBING SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL FIXTURES IN THIS <br />SCHEDULE OR THEIR APPROVED EQUIVALENT. REFER TO <br />F- <br />ARCHITECTURAL DRAWINGS FOR ALL MOUNTING HEIGHTS OF FIXTURES. <br />WC -1 <br />ACCESSIBLE WATER CLOSET: KOHLER "K-4405 "HIGHLINE" FLUSH <br />VALVE TYPE, 11/81/2" TOP SPUD, FLOOR MOUNTED, 10" ROUGH/81N, WHITE <br />VITREOUS CHINA, ELONGATED BOWL, DIRECTS/&FED SIPHON JET ACTION, <br />128 GFF, RIM 111/81/2" AFF. UNIT COMPLETE WITH KOHLER "K -46101/8C <br />OPEN FRONT SEAT LESS COVER, MATCHING BOLT CAPS, SLOAN <br />W <br />"ROYAL" "III -128 CHROME PLATED FLUSH VALVE, TRIP LEVER LOCATED <br />ON OPEN SIDE OF FIXTURE. UNIT SHALL CONFORM TO STATE ACCESS <br />� <br />REGULATIONS AND TITLE 24 REQUIREMENTS FOR ACCESSIBLE <br />INSTALLATIONS. <br />LAVATORY: KOHLER -2005 "KIN STOW WA HU VI%MODEL HIN , <br />W <br />- <br />F CHICAGO CHROME PLAT D FAUC2 <br />40 <br />Q-Al2A-43A"T, <br />�Na <br />T C X T <br />(0.5 GPM FLOW), AND METAL GRID DRAIN ASSEMBLY. INSULATE WATER <br />AND WASTE PIPING. UNIT SHALL CONFORM TO STATE ACCESS <br />REGULATIONS AND TITLE 24 REQUIREMENTS FOR ACCESSIBLE <br />INSTALLATIONS. <br />2" FD <br />FLOOR DRAIN: JR. SMITH " 2005(A), 5" DIAMETER NICKEL BRONZE TOP <br />WITH 2" PIPE, FLANGE AND SEEPAGE PAN. PROVIDE TRAP PRIMER <br />CONNECTION. <br />3" FS <br />FLOOR SINK: JR5 PRODUCTS 0325-YO3 WITH CAST IRON BODY, <br />ENAMELED INTERIOR, 6" DEEP SUMP, FLANGE AND SEEPAGE PAN, <br />ALUMINUM BOTTOM DOME STRAINER, HALF GRATE, 3" OUTLET, CAULK <br />JOINT. <br />BFP <br />WATTS SD3-MF 3/8" ASSE 1022 BACKFLOW PREVENTER FOR CARBONATE <br />BEVERAGE MACHINES, COFFEE MACHINE, TEA BREWER AND ESPRESSO <br />MACHINE. DRAIN TO FLOOR SINK. <br />MS <br />MOP SINK: FLORESTONE MODEL 'MSR -2424 FLOOR MOUNTED, 3" OUTLET <br />WITH AMERICAN STANDARD "8344.012 FAUCET WITH TOP BRACE, STOPS <br />AND VACUUM BREAKER, AND AMERICAN STANDARD 01121.038 DRAIN <br />WITH STRAINER <br />eWATER <br />HEATER: BRADFORD WHITE "EF -60T -125-3N, GAS FIRED, 125,000 <br />i <br />BTUH INPUT, 60 GALLON STORAGE CAPACITY, 188 GFH RECOVERY AT <br />60 F RISE. GLASS LINED STORAGE TANK, MAGNESIUM ANODE, <br />INSULATED AND JACKETED, CAST IRON BURNER, PRESSURE AND <br />TEMPERATURE RELIEF VALVE. INSTALL WITH EXPANSION TANK, AMTROL <br />"ST -5 "THERM-X-TROL", DIAPHRAGM TYPE, PREPRESSURIZED TANK <br />WATER AND WASTE SERVICE CALCULATIONS <br />JOB NAME: TAQUERIA LA ESTRELLA DATE: 01/14/20 <br />FIXTURE TYPE <br />NO. <br />WASTE <br />COLD WATER <br />HOT WATER <br />TOTAL <br />WATER <br />FU <br />TOTAL <br />FU <br />TOTAL <br />FU <br />TOTAL <br />FU <br />3 -COMPARTMENT SINK <br />1 <br />3 <br />3 <br />1.125 <br />1.125 <br />1.125 <br />1.126 <br />1.5 <br />LAVATORY <br />1 <br />1 <br />1 <br />0.75 <br />0.76 <br />0.75 <br />0.75 <br />1 <br />MOP SINK <br />1 <br />3 <br />3 <br />2.26 <br />2.26 <br />2.25 <br />2.25 <br />3 <br />HAND SINK <br />2 <br />2 <br />4 <br />1.5 <br />3 <br />1.5 <br />3 <br />4 <br />PREP SINK <br />1 <br />3 <br />3 <br />1.6 <br />1.6 <br />1.5 <br />1.6 <br />2 <br />WATER CLOSET, 1.28 FV <br />2 <br />4 <br />8 <br />6 <br />10 <br />0 <br />0 <br />10 <br />MISC EQUIP (ICE, SODA, COFFI <br />2 <br />1 <br />2 <br />1 <br />2 <br />0 <br />0 <br />2 <br />FUTURE RESTAURANT (SMALL <br />0 <br />30 <br />0 <br />30 <br />0 <br />0 <br />0 <br />0 <br />FUTURE RESTAURANT (LARGE <br />0 <br />60 <br />0 <br />60 <br />0 <br />0 <br />0 <br />1 0 <br />TOTAL FU <br />1 <br />24.0 <br />20.6 <br />8.6 <br />1 23.6 <br />EQUIVALENT COLD WATER FLOW RATE (GPM): 37 GPM <br />ADDITIONAL DEMAND LOAD (GPM) 0 0 GPM <br />PRESSURE AVAILABLE AT STREET MAIN (PSI): 40 PSI <br />MINIMUM REQUIRED FIXTURE PRESSURE (PSQ: 8 PSI <br />1 6 IFT 3 PSI <br />ELEVATION RISE (FT): <br />METER LOSS (PSI): 3 PSI <br />BACKFLOW PREVENTER LOSS (PSI): 10 PSI <br />ADDITIONAL LOSSES (PSI): 0 PSI <br />EQUIVALENT PIPE LENGTH FROM METER TO MOST REMOTE FIXTURE (FT 300 FT <br />FRICTION LOSS PRESSURE AVAILABLE (PSI): 16.40 <br />MAXIMUM ALLOWABLE FRICTION LOSS (PSI/100 FT): 5.47 <br />WATER FLOWVELOCITY (FPS): 3.79 <br />CALCULATED FRICTION HEAD LOSS (PS111100 FT): 1.54 <br />MINIMUM REQUIRED 'WATER' PIPE SIZE (INCHES): 2 <br />MINIMUM REQUIRED 'WASTE' PIPE SIZE (INCHES): 3 <br />(CALCULATIONS PER THE UPCICPC) <br />Q DESCRIPTION DATE <br />D <br />©BLDG DEPARTMIE <br />0 <br />A <br />STAMP <br />�NPRC ' S •c •.��c <br />Na.958 <br />Sp'• .,CIVIL, . ��P <br />Date Signed: January 15, 2020 <br />Q <br />W <br />F- <br />M <br />W-�Q <br />W <br />V <br />Z <br />Q <br />� <br />apV <br />00I <br />W <br />- <br />W <br />40 <br />Z <br />�Na <br />cy <br />m <br />SHEET TITLE <br />ILUMBING LEGENI <br />AND SCHEDULES <br />DATE OCTOBER 8, 2019 <br />DRAWN BY EH <br />CHECKED BY BC <br />SCALE: as noted <br />SHEET <br />il <br />