My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2022 12:49:48 PM
Creation date
1/6/2021 8:49:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0504388
PE
2361
FACILITY_ID
FA0006185
FACILITY_NAME
STOCKTON FOOD AND GAS
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
01
SITE_LOCATION
1605 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for EI Dorado Gas & Mart as of December 24, 2020. <br /> Open violations from May 28, 2020 inspection <br /> Violation#208-Failure to conduct the designated UST operator visual inspection at least once every 30 <br /> days. <br /> OBSERVATION:The designated operator failed to check and note all required items on the visual inspection <br /> reports.The incorrect and missing information included the following from the inspection reports: <br /> -The DO report of 11/14/2019 did not include the ownerloperator name,signature and date signed. <br /> REGULATION GUIDANCE:During the visual inspection,the designated operator shall check that all required <br /> testing and maintenance for the UST system have been wmpleted and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> IR This violation was corrected 0 This violation will be corrected by(date): <br /> IX Supporting documents included <br /> Describe actions taken or will be taken to correct violation: The document has been signed and updated <br /> Scanned copy is enclosed for reference <br /> Violation#209-Failure to maintain the"Facility Employee Training Certificate"on-site(after October 1, <br /> 2018). <br /> OBSERVATION:The Facility Employee Training Certificate dated 6/1412019 did not have date of assuming <br /> responsibility as a facility employee. <br /> REGULATION GUIDANCE:All site employees must be trained prior to taking responsibility as a facility employee if <br /> after October 1,2018, or within 30 days of hire if prior to October 1,2018. The Facility Employee Training <br /> Certificate shall contain accurate information for all employees trained_ <br /> CORRECTIVE ACTION: Update the Facility Employee Training Certificate to contain the accurate information and <br /> submit a copy of the updated form to the EHD. <br /> This violation was corrected ©This violation will be corrected by(date): <br /> Supporting documents included <br /> Describe actions taken or will be taken to correct violation: The document has been updated <br /> Page 7 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.