My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013872
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4010
>
2600 - Land Use Program
>
PA-1900284
>
SU0013872
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2021 8:42:05 AM
Creation date
1/8/2021 11:43:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013872
PE
2631
FACILITY_NAME
PA-1900284
STREET_NUMBER
4010
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215-
APN
14333029
ENTERED_DATE
1/7/2021 12:00:00 AM
SITE_LOCATION
4010 E FREMONT ST
RECEIVED_DATE
1/7/2021 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PA-1900284 – Conditions of Approval 3 <br />1. A building permit for each separate structure or building is required. Submit plans, <br />Specifications and supporting calculations, prepared by a Registered Design Professional <br />(architect or engineer) for each structure or building, showing compliance with The 2019 <br />California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes <br />as may be applicable. Plans for the different buildings or structures may be combined into a <br />single set of construction documents. <br />2. A grading permit will be required for this project. Submit plans and grading calculations, <br />including a statement of the estimated quantities of excavation and fill, prepared by a <br />Registered Design Professional. The grading plan shall show the existing grade and finished <br />grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br />show in detail that it complies with the requirements of the code. The plans shall show the <br />existing grade on adjoining properties in sufficient detail to identify how grade changes will <br />conform to the requirements of the code. <br /> <br />3. The required plans must be complete at the time of submittal for a building permit. Plans must <br />address building design and construction, fire and life safety requirements, accessibility and <br />show compliance with the current California codes and San Joaquin County ordinances. A <br />complete set of plans must include fire sprinkler plans, truss design submittals, metal building <br />shop drawings, structural plans and calculations, plumbing, electrical and mechanical drawings <br />and energy report. <br /> <br />4. A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br />for grading. All recommendations of the Soils Report shall be incorporated into the construction <br />drawings. <br /> <br />For each proposed new building, provide the following information on the plans: <br /> <br />A. Description of proposed use <br />B. Existing and proposed occupancy Groups <br />C. Type of construction <br />D. Sprinklers (Yes or No <br />E. Number of stories <br />F. Building height <br />G. Allowable floor area <br />H. Proposed floor area <br />I. Occupant load based on the CBC <br />J. Occupant load based on the CPC <br /> <br />5. Accessible routes shall be provided per CBC § 11B-206. At least 1 accessible route shall be <br />provided within the site from accessible parking spaces and accessible passenger loading <br />zones; public streets and sidewalks; and public transportation stops to the accessible building <br />or facility entrance they serve. Where more than 1 route is provided, all routes must be <br />accessible. §11B- 206.2.1 <br /> <br />6. At least 1 accessible route shall connect accessible buildings, accessible facilities, accessible <br />elements and accessible spaces that are on the same site. §11B-206.2.2 <br /> <br />7. At least 1 accessible route shall connect accessible building or facility entrances with all <br />accessible spaces and elements within the building or facility, including mezzanines, which are <br />otherwise connected by a circulation path. §11B-206.2.4 <br /> <br />8. Parking spaces will be required to accommodate persons with disabilities in compliance with <br />Chapter 11B of the California Building Code. Note that accessible parking spaces are required <br />for each phase of the project. These parking space(s) shall be located as close as possible to <br />the primary entrance to the building. <br />