Laserfiche WebLink
Environmental Health Department <br /> SAN 10AQUIN <br /> COUNTY Jasjit Kang , RENS, Director <br /> Muniappa Naidu, REHS, Assistant Director <br /> PROGRAM COORDINATORS '.. <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> Willy Ng, REHS <br /> Michael Kith, REHS <br /> Melissa Nissim, REHS '.. <br /> February 22 , 2021 <br /> Dan Rauscher <br /> Granite Petroleum , Inc. <br /> 3726 E Boone Ave <br /> Spokane , WA 99202 <br /> Re : SAFEWAY FUEL CENTER #2600 SR0082924 <br /> 1987 W ELEVENTH ST, TRACY, CA 95376 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the application for a permit to do the following on the underground storage tank (UST) system at <br /> the above noted address: <br /> • Replace existing product piping <br /> • Replace existing ten ( 10) dispensers and under-dispenser containment sumps <br /> • Replace three (3) turbine sumps <br /> • Replace three (3) turbine manways <br /> • Replace six (6) spill containers <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements. <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustpsjgay. org to arrange the following appointments (a 48- <br /> hour notice is required for inspection appointments) . <br /> a) Witness water and/ or soil sampling under removed UDCs and piping . <br /> b) Primary piping soap test of all piping and penetrations (product) : One hour pneumatic <br /> pressure test at 110% of operating pressure , or 40 psi , whichever is greater. <br /> c) Secondary piping soap test of all piping and penetrations (product) : One-hour pressure <br /> test at the manufacturers recommended specification . <br /> d) Secondary piping slope , at 1 / 8 inch per foot or greater, to a containment sump with an <br /> audible/visual alarm . <br /> e) Verification of all pipe setbacks and burial depth according to the manufacturer's <br /> installation Instructions. Verification of appropriate backfill . <br /> f) Integrity testing of all STP sumps and UDCs per the manufacturer's installation <br /> instructions . <br /> g) Since concrete will be broken near the tanks , sumps, or existing piping , a secondary <br /> containment test must be performed on the affected components once concrete is poured <br /> in accordance with the manufacturer's guidelines. <br /> h) Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic test <br /> (or equivalent) . Proper drainage must also be verified . <br /> 1868 E . Hazelton Avenue I Stockton, California 952051 T 209 468-34201 F 209 464-0138 1 www.sjgov.org/ehd <br />