My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL PINAL
>
1325
>
2231-2238 – Tiered Permitting Program
>
PR0543720
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2022 11:40:34 AM
Creation date
1/12/2021 8:57:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0543720
PE
2231
FACILITY_ID
FA0024706
FACILITY_NAME
METAL FINISHING SOLUTIONS - STOCKTON CA
STREET_NUMBER
1325
STREET_NAME
EL PINAL
STREET_TYPE
DR
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1325 EL PINAL DR STE 1
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Metal Finishing Solutions, Inc. <br />SELF -!MONITORING SAMPLE PROGRAM <br />The permittee, Metal Finishing Solutions, Inc., located at 1325 EI Pinal Drive, shall perform the following self-monitoring <br />sample program effective October 1, 2018, and continuing until the complete expiration of this permit. The permittee shall <br />perform sample monitoring for the listed pollutant parameters using sample frequencies, sample types, and <br />methodologies specified in this self-monitoring sample program. All handling and preservation of the collected samples <br />and laboratory analyses of samples shall be performed in accordance with 40 CFR Part 136, and amendments thereto, <br />unless otherwise specified in the monitoring conditions of this permit. <br />The permittee shall sample for pollutant parameters at those designated sample location points identified below,- <br />Sample <br />elow; <br />Sample Point Locations <br />Sample Point No. <br />Sample Point Description <br />001 <br />Final Effluent Automatic Sampler <br />002 <br />Final Effluent Grab Sample Spigot <br />003 <br />Final Effluent Flow Monitor <br />004 <br />Final Effluent pH Monitor <br />Sample <br />Discharge Limit <br />Pollutant <br />Sample <br />p <br />Sample <br />p <br />Location <br />(1) Instantaneous maximum <br />Parameter <br />Frequency <br />Type <br />(diagram <br />(2) Daily maximum <br />attached) <br />(3) Monthly maximum <br />(4) Monthly average <br />Flow <br />Continuous <br />Metered and <br />003 <br />130,000 gallons/month - local limit <br />recorded <br />(3) <br />15 gallons/minute - local limit (1) <br />pH <br />Continuous <br />Metered and <br />004 <br />5.0-10,0 —local limit (1) <br />recorded <br />Cadmium, total <br />1 per 6 months <br />24-hour flow <br />001 <br />0.11 mg/L - categorical limit (2) <br />proportional <br />0,07 mg1L - categorical limit (4) <br />composite, <br />representative of <br />reporting period. <br />Copper, total <br />1 per 6 months <br />24-hour flow <br />001 <br />3.38 mg/L - categorical limit (2) <br />proportional <br />composite, <br />2,07 mg/L - categorical limit (4) <br />representative of <br />reporting period. <br />Chromium, total <br />1 per 6 months <br />24-hour flow <br />001 <br />2.77 mg/L - categorical limit (2) <br />proportional <br />composite, <br />1.71 mg/L - categorical limit (4) <br />representative of <br />reporting period. <br />Lead, total <br />1 per 6 months <br />24-hour flow <br />001 <br />0.69 mg/L - categorical limit (2) <br />proportional <br />composite, <br />0.43 mg1L - categorical limit (4) <br />representative of <br />reporting period. <br />Nickel, total <br />1 per 6 months <br />24-hour flow <br />001 <br />3.98 mg1L - categorical limit (2) <br />proportional <br />composite, <br />2.38 mg1L - categorical limit (4) <br />representative of <br />reporting period. <br />Zinc, total <br />1 per 6 months <br />24-hour flow <br />001 <br />2.61 mg1L - categorical limit (2) <br />proportional <br />composite, <br />1,48 mg1L - categorical limit (4) <br />representative of <br />reporting period. <br />
The URL can be used to link to this page