My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL PINAL
>
1325
>
2231-2238 – Tiered Permitting Program
>
PR0543720
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2022 11:40:34 AM
Creation date
1/12/2021 8:57:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0543720
PE
2231
FACILITY_ID
FA0024706
FACILITY_NAME
METAL FINISHING SOLUTIONS - STOCKTON CA
STREET_NUMBER
1325
STREET_NAME
EL PINAL
STREET_TYPE
DR
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1325 EL PINAL DR STE 1
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />CCUNT <br />Environmental Health Department <br />Permit By Rule Treatment Facility Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />METAL FINISHING SOLUTIONS - STOCKTON <br />1325 EL PINAL DR, STOCKTON <br />July 20, 2021 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />Title 22 California Code of Regulations section 66270.11 <br />(d) Certification. I certify under penalty of law that this document and all attachments were prepared under my <br />direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and <br />evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those <br />persons directly responsible for gathering the information, the information submitted is, to be the best of my <br />knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting <br />false information, including the possibility of fine and imprisonment for knowing violations. <br />Title 22 California Code of Regulations section 66265.192(k) <br />The tank system assessment shall include all of the following information: <br />(1) tank configuration (i.e., horizontal, vertical), material of construction, and gross capacity (in gallons); <br />(2) design standard(s), if available, according to which the tank and ancillary equipment were or will be constructed <br />and all of the following information: <br />(A) material of construction; <br />(B) material thickness and the method used to determine the thickness; <br />(C) description of tank system piping (material, diameter); <br />(D) description of any internal and external pumps; and <br />(E) sketch or drawing of tank including dimensions. <br />(3) documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the <br />age); <br />(4) description and evaluation of any leak detection equipment; <br />(5) description and evaluation of any corrosion protection equipment, devices, or material; <br />(6) description and evaluation of any spill prevention or overfill equipment; <br />(7) description and evaluation of secondary containment for the tank system (secondary containment must meet <br />minimum standards as specified in subsections 0)(1) through 0)(3) of this section) including applicable secondary <br />containment for ancillary equipment as required in subsection 66265.193(f); <br />(8) hazardous characteristics of the waste(s) that have been or will be handled; <br />(9) prior to placing a new tank system or component in use, an independent, qualified installation inspector or an <br />independent, qualified, professional engineer, registered in California, either of whom is trained and experienced in <br />the proper installation of tank systems, shall inspect the system or component for the presence of any of the <br />following items and document in writing the results of the inspection: <br />(A) weld cracks or breaks; <br />(B) scrapes of protective coatings; <br />(C) corrosion; <br />(D) any structural damage or inadequate construction or installation such as cracks, punctures, damaged fittings. All <br />discrepancies shall be documented in the assessment and remedied before the tank system is placed in use. <br />(10) all new tanks and ancillary equipment shall be tested for tightness prior to being placed in use. The results of <br />the test(s) shall be documented in this assessment. Tank system integrity or leak test requirements must be in <br />compliance with all local requirements. Prior to conducting a tank system integrity test or leak test, contact local <br />agency staff for local requirements. <br />(11) estimated remaining service life of the tank system based on findings of subsections (k)(1) through (k)(10). <br />Title 22 California Code of Regulations section 66265.1920) <br />(1) tank system must have secondary containment capable of containing 100 percent of the contents of the tank <br />and ancillary piping volume; and <br />(2) if the tank system is exposed to precipitation, the secondary containment system must have sufficient capacity, <br />FA0024706 PR0543720 SCO01 07/20/2021 <br />EHD 22-04 Rev. 9/16/2020 Page 8 of 11 Permit By Rule Treatment Facility OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.