Laserfiche WebLink
Site : GRIN ARCO <br /> Appendix B Date : 10/ 15/21 <br /> 71 SO Overfill Valve in Tank Shut off Level Worksheet Tank ID DIESE Tester FEId <br /> Important : This is meant to be supplemental worksheet and not a substitute to following the installation <br /> manual instructions . All length measurements are in inches . Please contact the Authority Having Jurisdic- <br /> tion (AHJ ) and review local, state, and national codes to determine the regulatory requirements governing <br /> shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt . <br /> Take the following measurements with the valve in - <br /> stalled in the tank: <br /> Distance from the 71 SO inlet tube flange to the cast <br /> lug in the 71 SO body ( see figures ) , upper tube length . <br /> Note: the Upper Tube Length must be at least 16" to in - <br /> clude the protective bend in the tube. <br /> ( D ) = 85.250 <br /> 0 <br /> Distance from the 71 SO inlet tube flange to the top and JL <br /> bottom of lower tube, valve length . (D) <br /> (W) = 190 Upper <br /> ( U ) = 191 Tube <br /> Distance from the 71 SO inlet tube flange to the bottom rj <br /> of the tank. Note : If a tank bottom protector is present it <br /> may be necessary to add this thickness to dimension <br /> (OPW 6111 & 61TP models add 0 .6") (W) Valve <br /> ( B) = 194 Length, <br /> bottom of <br /> From the tank calibration chart provided by tank manu - cut <br /> facturer find the dipstick number (Y) which corresponds <br /> to the 100 % volume . ( B) <br /> (Y) = 120 To Tank <br /> (Y) <br /> 1 . To determine shut-off percentage: Tank <br /> Subtract upper tube length ( D) from distance to tank ( U) Valve Chart <br /> bottom ( B) Length, 100% <br /> (X) _ ( B) - ( D ) - 2" = 106 .750 top of cut Volume <br /> Dipstick <br /> Using the tank calibration chart provided by the tank <br /> manufacturer determine the tank capacity at the cal- <br /> culated (X) dimension and the 100% volume (Y) tank <br /> capacity. <br /> (X) tank capacity in gallons = 7499 <br /> (Y) tank capacity in gallons = 7901 <br /> SO% _ (X) capacity / (Y) capacity x100 = 94.9 % <br /> Note: The overfill valve must be installed per AHJ require- <br /> ments and all applicable local, state, and national codes . If <br /> the overfill valve is set above the allowable shut-off percent- <br /> age the overfill valve must be removed and replaced . For <br /> reference 40 CFR part 280 Subpart B Section 280 . 20 overfill <br /> valves should be set to a maximum of 95%. <br /> 21 <br />