Laserfiche WebLink
Site: GRIN ARCO <br /> Appendix B Date : 10/ 15/21 <br /> 71 SO Overfill Valve in Tank Shut off Level Worksheet Tank ID 91 Tester FEld <br /> Important: This is meant to be supplemental worksheet and not a substitute to following the installation <br /> manual instructions . All length measurements are in inches . Please contact the Authority Having Jurisdic- <br /> tion (AHJ ) and review local, state, and national codes to determine the regulatory requirements governing <br /> shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. <br /> Take the following measurements with the valve in- <br /> stalled in the tank: <br /> Distance from the 71 SO inlet tube flange to the cast <br /> lug in the 71 SO body ( see figures ), upper tube length . <br /> Note : the Upper Tube Length must be at least 16" to in - <br /> clude the protective bend in the tube . <br /> ( D) = 84 .5 <br /> 0 <br /> Distance from the 71 SO inlet tube flange to the top and <br /> bottom of lower tube, valve length . ( D) <br /> (W) = 190 Upper <br /> ( U ) = 190 Tube <br /> Distance from the 71 SO inlet tube flange to the bottom <br /> of the tank. Note : If a tank bottom protector is present it <br /> may be necessary to add this thickness to dimension <br /> (OPW 6111 & 61TP models add 0 .6") (W) Valve <br /> ( B ) = 192 Length, <br /> bottom of <br /> From the tank calibration chart provided by tank manu - cut <br /> facturer find the dipstick number (Y) which corresponds <br /> to the 100 % volume . ( B) <br /> (Y) = 120 To Tank <br /> (Y) <br /> 1 . To determine shut-off percentage: Tank <br /> Subtract upper tube length ( D) from distance to tank ( U) Valve Chart <br /> bottom ( B ) Length, 100% <br /> (X) _ ( B) — ( D ) 111Y' = 105 .5 top of cut Volume <br /> Dipstick <br /> Using the tank calibration chart provided by the tank <br /> manufacturer determine the tank capacity at the cal- <br /> culated (X) dimension and the 100% volume (Y) tank <br /> capacity. <br /> (X) tank capacity in gallons = 11283 <br /> (Y) tank capacity in gallons = 11907 <br /> 50% _ (X) capacity / (Y) capacity x100 = 94 , 7% <br /> Note: The overfill valve must be installed per AHJ require- <br /> ments and all applicable local, state, and national codes . If <br /> the overfill valve is set above the allowable shut-off percent- <br /> age the overfill valve must be removed and replaced . For <br /> reference 40 CFR part 280 Subpart B Section 280 .20 overfill <br /> valves should be set to a maximum of 95 %. <br /> 21 <br />