My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLAY
>
655
>
2300 - Underground Storage Tank Program
>
PR0231065
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2022 10:41:44 AM
Creation date
1/20/2021 9:40:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231065
PE
2361
FACILITY_ID
FA0003699
FACILITY_NAME
DSS COMPANY
STREET_NUMBER
655
Direction
W
STREET_NAME
CLAY
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14707110
CURRENT_STATUS
01
SITE_LOCATION
655 W CLAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
From:Isabel Cuevas Fax:18669896652 To: Fax:(209)468.3433 Page:4 of 6 01119120214:13 PM <br /> Environmental Health ea th Department <br /> ,, SANA0A0U <br /> .� F,:` Linda Turkat <br /> ,,; . , -C:OU NT - . te, REHS, Director <br /> , Kasey Foley,REHS,Assistant Director <br /> . rQ<i ...." �^ tne .s : �c� s enc.: <br /> PROGRAM COORDINATORS <br /> Robert McClellan,REHS <br /> Jeff Carruesco,REHS,RDI <br /> Michael Kith,REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu,REHS <br /> 6. Dispenser replacement due to structural damage(e,g.vehicular incident),without conversion frame <br /> installation <br /> 7. Manway lids replacement over USTs,which require concrete removal/replacement. <br /> 8. Sump lids repair/replacement for tanks installed after lune 30, 2003. <br /> All above repairs must have a plan check service request submitted to and approved by the EHD prior to <br /> beginning of work. If above components are repaired or replaced and the approved plan check service <br /> request is not obtained, a full permit must be submitted to the EHD and a"Failure to Obtain a Permit" <br /> penalty(an additional 100%of the current plan check service request fee)will apply. <br /> Emergency repairs relating only to the UST system monitoring and release detection, may be performed by <br /> a properly licensed,trained,and certified contractor as long as a complete plan check service request is <br /> submitted to the EHD within one business day of such emergency repair.A"Failure to Obtain a Permit" <br /> penalty(an additional 100%of the current plan check service request fee)will apply if the plan check service <br /> request is not submitted to the EHD within one business day.All required testing for emergency repair work <br /> must be scheduled within five days of the plan check service request approval. <br /> All repaired components must be tested within 30 days of repairs being made and test results must be <br /> submitted to the EHD within 30 days of testing.A 48-hour notification is required to be submitted to the <br /> EHD(via ust@sicehd.com prior to testing). <br /> *CONDITIONS FOR EHD PLAN CHECK ONLY REPAIRS <br /> This work requires EHD written approval prior to implementation: <br /> 1. Submit a Service Request form, a completed UST retrofit application form, pertinent cut sheets, <br /> all applicable technician's certifications, and a payment for 1 hour of review time at the EHD's <br /> current hourly rate <br /> 2. Once the application has been reviewed and approved, provide a 48-hour notification to the EHD <br /> of repair and testing by emailing to UST@sicehd.com or faxing to(209)468-3433. <br /> 3. The service company must install and test the repaired component(according to the <br /> manufacturer's installation instructions) to verify functionality. <br /> 4. The service company must provide the following documentation to the tank Owner/operator for <br /> inspector to review during annual UST inspection. <br /> a. Description of part(s) installed(parts list, cut sheets, etc.) <br /> b. Name& UST ICC#of Service technician performing the work (ICC, manufacturer <br /> certification proof, etc.,) <br /> c. Testing documentation to verify installation and functionality of the repair <br /> P A Ci I-: 12 1 Apry 2019 <br />
The URL can be used to link to this page