My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 4:03:29 PM
Creation date
1/20/2021 9:53:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f� PEI/RP1200-12 <br /> ATGs are programmed to monitor the product level in warnings or alarms. In the event of any <br /> storage tanks and can be programmed to perform com- such warnings or alarms, notify the appro- <br /> pliance tests that can include 0.2 gph static and dynamic priate person before continuing the test. <br /> ("continuous")leak tests,and 0.1 gph("precision")tests. <br /> Where possible print out the system setup <br /> 8.2.1 ATG Functionality Test. and any alarm histories from the console. <br /> 8.2.1.1 General. The ATG must bepro- <br /> Save the printout for facility records or <br /> make an electronic copy. <br /> grammed using site-specific parameters <br /> for the UST system to ensure proper opera- 8.2.1.5 Test Equipment. Test equip- <br /> tion. On dual float systems, the second ment shall include: <br /> float indicates the level of water in the • tools for the removal of the ATG probe <br /> tank. <br /> and sensors; <br /> 8.2.1.2 Purpose. The purpose of this • tape measure or gauge stick; <br /> test is to: <br /> • determine whether the ATG shows the • water-finding paste. <br /> correct product level on the console; 8.2.1.6 Test Procedure. <br /> • determine whether the ATG shows the 1.Measure the product and water level <br /> correct water level on the console; in the tank and compare to the console <br /> • verify that the water alarm is operating readings to confirm ATG accuracy. If <br /> correctly and provides a warning at the the readings do not agree, contact the <br /> programmed set point. appropriate person. <br /> 2.Remove the ATG probe cap and discon- <br /> WARNING: Water ingress into tanks con- nect the cable from the ATG. <br /> taining ethanol-blended gasoline may not 3.Remove the ATG probe from the tank. <br /> be detected using water floats designed Use care to ensure that the floats on the <br /> for non-ethanol-blended gasoline. stem do not catch on the bottom of the <br /> riser during removal. <br /> 8.2.1.3 Description of Test. The pro- 4.Inspect the probe.The floats must move <br /> cedures in this test are for a probe,properly freely on the stem without binding. If <br /> installed per manufacturer's instructions, any parts are damaged or missing, con- <br /> equipped with floats having a range inside tact the appropriate person. <br /> the tank that extends from the bottom to 5.Reconnect the probe cable. <br /> the top of the tank. <br /> 6.Set the fuel float in the middle of the <br /> The ATG probe is removed from the tank, probe and verify that it is showing the <br /> The product float and water float positions correct inch reading on the console. <br /> are compared with the console readout. 7.Slowly move the fuel float up the probe <br /> 8.2.1.4 Preparation. Use this test pro- until the high product alarm is triggered <br /> cedure in conjunction with the monitor- on the console. If the system does not <br /> ing system manufacturer's installation and alarm at the pre-set level, contact the <br /> maintenance instructions. appropriate person. <br /> Refer to the tank manufacturer's tank 8.Measure the distance from the bot- <br /> chart for the capacity in gallons, the diam- tom of the probe to the fuel float when <br /> eter and the volume of product that corre- the float first triggers the high product <br /> sponds to the product level. alarm. <br /> Verify that the console has no active or 9.Clear the alarm conditions. <br /> recurring history of leak detection-related <br /> ® peLorg <br />
The URL can be used to link to this page
Your browser does not support the video tag.