My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
11530
>
2800 - Aboveground Petroleum Storage Program
>
PR0516703
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2025 4:18:51 PM
Creation date
1/25/2021 10:38:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0516703
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0003930
FACILITY_NAME
KING ISLAND MARINA
STREET_NUMBER
11530
Direction
W
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95219
APN
07119006
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
11530 W EIGHT MILE RD STOCKTON 95219
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. Introduction to Inspection <br /> eFUEL, LLC. is pleased to present the following SP001 Formal External Inspection Report. This <br /> report details the results from the Formal External Inspection conducted at King Island Resort <br /> located at 11530 W. Eight Mile Rd. Stockton, CA 95219 on November 5, 2020 by STI/SPFA <br /> Aboveground Tank Inspector, Jon Lorente (STI Inspector No: AST-2069) from eFUEL, LLC. <br /> located in San Jose, CA. This inspection was required by Inspector J. Witful of the United States <br /> Environmental Protection Agency. <br /> The inspection followed the STI SP001 standard and focused on records review, testing the <br /> Veeder-Root tank monitor alarm, observing the foundation, tank type, tank category, UL <br /> Standard verification, piping, venting, sensors, methods of leak detection, NFPA requirements <br /> and electrical. Due to the observed corrosion on the exterior of the tank shell, Ultrasonic <br /> Thickness Testing was required under the SP001 standard. I was also informed that Bagley <br /> Enterprises conducted a pressure test on the tank. <br /> The sections below outline the facility per the SPCC plan, system components and observations <br /> and both the recommended and required actions for continued tank use to be in compliance <br /> with the STI SP001 Standard. <br /> 2. Facility Description Per the Existing SPCC Plan <br /> Facility Name: King Island Resort <br /> Owner or Operator Name: P.S. Marina 5 <br /> Address: 11530 W. Eight Mile Rd. Stockton, CA 95219 <br /> Phone: 209-951-2188 <br /> The King Island Resort (Marina) is located inland on two sloughs. Onsite is a 10,000 gallon <br /> aboveground fuel storage tank located below the marina water level on the land side of a flood <br /> control levee foer the San Joaquin Delta Sloughs. The tank is supported by a designed concrete <br /> slab. The tank is double walled and equipped with a Veeder-Root Leek Detection and fuel level <br /> monitoring system. The leak detection system provides test documentation of no leakage on a <br /> 24 hour (daily) time period. Overfill and malfunction alarms are part of this system... Fuel is <br /> pumped from the aboveground tank 125' to the fuel dock fuel dispensers by an explosion <br /> controlled electrical (1.5 horse power) - 12 gallon per minute pump through (two) a 2 inch <br /> threaded steal pipeline. The pump is located at the top of the double walled storage tank. <br /> The fuel pipelines (one for premium and one for regular gasoline) leave the aboveground tank <br /> and lay close to the foundation of the office building on the ground surface. As the pipelines <br /> approach the levee road they are placed within a containment pipe with a leak detection <br /> system and that containment pipe is placed into a culverty through the levee. The pipes are <br /> below surface until they emerge on the water side of the levee. The pipelines run below the <br /> dock deck to the dispensers and are mounted on lever action hose support type hangers. There <br /> eFUEL, LLC 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.