Laserfiche WebLink
is a manual shut off valve for each pipeline located outside of the general store on the land side <br /> of the levee and on the water side of the levee by the gang plank and dock shack. The two <br /> pipelines run supported from the levee to the fuel dock. The fuel dock maintains two fuel <br /> dispensers. Emergency Shut-offs include electrical and manual devices such as the emergency <br /> shutoff switch located near the metering pumps and manual valves on the land side and the <br /> water side of the levee. <br /> The tidal water level rise and fall in this area is approximately 4-6 feet and the pipelines are <br /> designed to move with this tide using reinforced flexible piping. In case of the loss of the dock <br /> breaking free from its moorings, the pipelines have spring loaded breakaway valves installed. <br /> There is an emergency shut off switch located on the fuel dock and valves that can be closed <br /> manually stop the flow of fuel to the pumps. There are also electrical breakers located at the <br /> marina office that can be shutoff in the event of an emergency. <br /> 3. Aboveground Storage Tank System Description <br /> 3.1. AST Type/ Listing/ Construction Standard <br /> The inspected 10,000 gallon split gasoline Aboveground Storage Tank was constructed under UL <br /> Standard 2085 and is a Fireguard Lightweight Double Wall tank. According to the SP001 <br /> standard, the tank is categorized as a Category 1 tank due to having Spill Control and a <br /> Continuous Release Detection Method. The Spill Control requirement is satisfied due to the <br /> tank having a secondary containment system. The Continuous Release Detection Method <br /> requirement is satisfied due to the tank being a double wall Aboveground Storage Tank with <br /> visibility under the tank. The placard on the tank was painted over, but the model and serial # <br /> of the tank was legible and confirmed with the Steel Tank Institute to have been manufactured <br /> by Joor Manufacturing in 1999. The construction of the tank was observed to be consistent with <br /> the UL 2085 standard for Aboveground Storage Tanks. <br /> As noted prior, the tank is a split 10,000 gallon tank with a 6,000 gallon compartment holding <br /> regular gasoline and a 4,000 gallon compartment holding premium gasoline. Both <br /> compartments were equipped with primary vent tubes having EVR Approved vent caps, <br /> weighted Morrison Bros emergency vents for both primary tanks and a single weighted <br /> emergency vent for the secondary containment intersticial space. <br /> Tank Manufacturer: Joor Manufacturing <br /> Date of Production: 1999 <br /> Steel Tank Institute Serial Number: 10466 <br /> External Tank Dimensions: 338.5" long x 102" diameter. <br /> Internal Tank Dimensions: 312" long x 95" diameter. <br /> AST Category: Category 1 Tank <br /> FUEL, LLC 4 <br />