Laserfiche WebLink
I�QSi•PNG tI,Rltt!tt EXtSMNO TAW ANSU <br /> SUMP (TM, OF 4) <br /> (TIP. OF S) r <br /> EX4TIK FILL <br /> (TWI OF 7)TANK 0,3 <br /> I <br /> EXISTING <br /> 20.000 - yI 1 I 325r0 W <br /> GALLONI Rd <br /> FIrI <br /> TANK 02 <br /> (67 OCTANE) --- <br /> t <br /> GAIAON <br /> IF <br /> " I <br /> LXISTING — <br /> TAMC # N . . .,.�„- --- _ - <br /> (87 OCTME) I ISI7NG f4 <br /> 20,000 ADDTITYE <br /> SUN ; <br /> TA Scope of Work <br /> I - - <br /> EusnaF <br /> F ��UN ' � — u • 91A and 91B Product secondary piping failed SB989 testing. <br /> m <br /> ( ) - - - - C7 <br /> • • _--� 91A/B secondary piping failed due to bad test boots in UDC' s 1/2 <br /> FASTNR r" FIFMME I-- - - - - - -- -- ,I and 11/12. We will remove and replace the test boots and retest <br /> U�MtE WALL PAWOCT ti • • _ f <br /> PIP4b` 91A/B secondary piping . If testing passes, repairs will be <br /> DISTP4C 4' OYM a' Cry a�TrlrG complete . If testing fails, we will troubleshoot and replace <br /> oaIBLE WALL M7 RISMS <br /> nacouAss vApoR additional test boots as needed to achieve passing results . <br /> RE181FJtY \ti`� • Ll 1/2, 3/4 and 11/12 failed SB989 secondary containment <br /> nNO ESO testing. <br /> ExI9nNC MR `� `" + - UDC's 1/2 and 11/12 failed due to bad test boots on the 91A/B <br /> DrWSIAE ` ``1 E fkGL <br /> "SMU Wftf"R IAbOt �y ' F l = i- ALARM secondary piping. We will remove and replace the test boots as <br /> ALARM MONITOR - <br /> SYSTE3l, MONITtrin 24 l =--_ - - -_- --- -- needed and retest the ILL If testing passes, repairs will be <br /> FY. HUCRS/DAY I complete . If testing fails we will troubleshoot and replace entry <br /> - -- -- <br /> -- - _ _ STING <br /> H uY e.r , fittings as needed to achieve passing results. <br /> FIF— — C==4 • iN F' • UDC 3/4 failed possibly due to bad entry fittings but no visual <br /> � <br /> /1 2 —LLI ___ ' issues were found . We will tighten and adjust existing entry <br /> 9/10 I - i— 5/6 — —_-- 1 r G+ • • fittings and retest the UDC. If testing passes, repairs will be <br /> Imo' ( a I u I11 complete . If testing fails we will troubleshoot and replace entry <br /> fittings as needed to achieve passing results . <br /> / • We will remove/replace the existing conduit and piping entries as <br /> Ui needed in each UDC. <br /> We will install (4) Icon Mfg #IRF10132.5 2" piping entry, ( 1 ) Icon <br /> ExI!:TIIJ: f:4 111 I _n I I r) ® Mfg #IRF8B3 .5 3" piping entry ( 2) Icon Mfg # IRF4B1 .4M conduit <br /> t - entry fitting as needed in each UDC . <br /> i 3/4 • We will pretest all repaired components. <br /> f = 11/ 12 - 7/8 Our technicians are ICC and Manufacturer certified . <br /> y � • Local Regulatory Agency will be notified for any required <br /> inspections and forthe re-testing of repaired components . <br /> Costco Facility No . 0658 Site Location and Facility Layout <br /> 3250 W. Grant line Road 401 .� A � J ; 82131 GQmm0nwoaHh 1Vfi?0 6 <br /> Tracy CA 95377 <br />