My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082610
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
13650
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0082610
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2021 4:12:58 PM
Creation date
2/2/2021 2:56:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0082610
PE
4219
STREET_NUMBER
13650
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
LODI
Zip
95242
APN
05514023
ENTERED_DATE
9/16/2020 12:00:00 AM
SITE_LOCATION
13650 N THORNTON RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\fgarciaruiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALLATION (2 of 2) _ Tablet <br /> ,o <br /> Riser Height Needed Risers Required <br /> TELEG LIDE RISER(24 SERIES) 0-3-1/2" None(use adapter) <br /> INSTALLATION GUIDELINES >3-1/2'-22" SR24 <br /> Tools needed:7/16'Nut driver tool/bit(included),marker(included), Adapter >22' 37" LR24 <br /> tape:measure and drill with 1/2'chuck.Jigsaw,circular saw or <br /> reciprocating saw will be needed if risers need to be cut. <br /> NOTE:To remove a component or adjust its position,the Uppei <br /> Band Clamp needs to be loosened or removed using nut driver bit. <br /> Loosened clamps should be retightened to 5-8 ft lbs.of torque <br /> (same;as a rubber no-hub coupling).The Lower Band Clamp is SR24 <br /> factory set and should not be adjusted or removed. S1 10er Riser } <br /> Adapter <br /> Riser Assembly Instructions/Steps Riser <br /> 1. Set unit so the pipe connections line up with jobsite piping and Height <br /> measure riser height needed from top of cover to finished grade. Needed <br /> See*'able 1 to select risers needed. Riser <br /> 2. Remove covers from adapters.Remove adapters from main unit. Alignment Mark } <br /> On a level surface,pre-assemble the risers and adapters, - ---------- <br /> adjusting the components upwards or downwards to achieve; LR24 5' <br /> the riser height.needed.Make sure to maintain minimum and Long Riser <br /> maximum insertion depths as shown in Figure 2. If components __ Cut lino. _� 1 <br /> aro:too long,make a circular line around the sidewall with <br /> marker and cut with a power saw.The lowest rut line on the riser <br /> assembly will be 5"beyond the riser height needed to allow for <br /> ideal insertion depth(See Figure 1).An alignment mark should be <br /> drawn]'beyond the riser height needed which will align with the TeleGlide Riser <br /> top of the base unit gasket.DO NOT c:ut the alignment mark.The <br /> Adapters and risers should sit level with each other.Tighten Figurents <br /> upper clamps to keep riser/adapter assembly from shifting. <br /> Make alignment marks on the sidewalls at the top of all riser <br /> gaskets to aid final assembly. Cover <br /> 3. IMPORTANT:Before the next step, make sure both diffusers <br /> are installed inside the main unit at the appropriate locations. <br /> Check if there needs to be any flow control adjustment at the <br /> inlet diffuser(see general installation instructions). Adapter(shown) <br /> 4. Take apart riser assembly and clean all sidewalls and insides of or Riser <br /> gaskets to remove dust/debris.Install components into the main Gasket <br /> unit starting from the lowest riser and work your way up to <br /> finished grade.Maintain minimum and maximum insertion Upper Band Clamp <br /> depths for all components(see Figure 2).1 ighten Upper Clamps 2 1/2'Minimum Insertion Depth (field adjustable) <br /> to specified torque after correctly positioning components.Riser Lower Band Clamp <br /> assembly may need to be supported during backfill. - - - - -- - --- -- - - - - - (factory set-do not <br /> 4'Maximum Insertion Depth adjust or remove) <br /> b. If tilting of the adapter is required to be flush with grade,do so (into GB unit only) <br /> AFTER all clamps have been tightened with risers)/adaptor in a - - - - -- -- --- - - - - - - GB Unit(shown) <br /> vertical and level position.Tilting is done using gasket flexibility, or Riser <br /> Tilting before tightening clamps may ruin a perfect gasket seal. <br /> Schier recommends tilting only the adapter versus the entire <br /> riser assembly to make sure your riser height and proper tank Depths <br /> access is maintained. Figure 2-Insertion <br /> S. If riser height conditions change after completing above steps, <br /> there may be room for adjustment.As long as minimum and <br /> maximum insertion depths are maintained(see Figure 2),the <br /> adaptors/risers can be adjusted/cut as many times as necessary. <br /> When riser system installation is complete,see Leak/Seal Testing Anchor hook <br /> procedure if reqt aired(p3 of 5). UTI <br /> X NO EaCEPION TA.[Nx <br /> - —ODAREETIONSNOID <br /> ❑A[IfcrtD � Tvu AND REwaMn <br /> ANCHOR KIT INSTALLATION ]—,SRECIEED HEM <br /> Anchor Strep <br /> [HE"LNG IS ONLY IN EONTORTMNCI WITH THE MNG. <br /> CONCIAT M 111E M.1111 AND GENfMI COMVnANCE <br /> Stainless steel anchor kit is recommended for installation in high WRH THE INEORMANON GIVEN IN THE CONINA0 <br /> GOCUMfN15.AM 9110H SHOWN 15 SUNECY 10 111 <br /> water table conditions to prevent float out.Necessity to be Anchor plate, AFOUREMENTS OT THE PLANS AND SHFOtlUTIONS <br /> CONI.a0 IS.""w TOR GIMENNONS— <br /> determined by specifying engineer.Hold down force achieved by SHMI RE CONFIRMED AND COARELATIU AT THE Wa WE: <br /> COORDINATION Of HIS—MNTN THAT OE ALL OTHEA <br /> backfill weight acting on Anchor Plate. _ AADES AND'.I ATIE A DAY 11NIONMANCF U1 HIS <br /> WDR, <br /> TURLEY AND ASSOCIATES,INC <br /> Slide Anchor Hook over tie down point on end wall and bolt to 7431 CAPITOL AVENUE <br /> Anchor Strap.Bolt Anchor Strap to Anchor Plate using SACRAMENTO.CA 95616 <br /> p g provided - Brian Provencal <br /> stainless steel hardware.If required,Anchor Plate may be bolted to GATE 0e104rzo2o er <br /> concrete slab using provided holes. ANCHOR KIT INSTALLATION DETAIL <br /> r] SCHIER <br /> LIFETIME GUARANTEED <br /> MODEL NUMBER: DESCRIPTION:Polyethylene Grease Interceptor <br /> G B��Q 50 GPM 52 gallon capacity <br /> GREASEINTERCEPTO <br /> - PART n:4025 001-XX DWG BY:C.O'Boyle DATE:10/08/2015 REV:O J�201_ ECO: <br /> 0 Copyright 2015 <br />
The URL can be used to link to this page
Your browser does not support the video tag.