ELECTRICAL SPECIFICATIONS <br />GENERAL <br />1. <br />NOTES: <br />ELECTRICAL INSTALLATION SHALL COMPLY WITH TITLE 24, CALIFORNIA <br />CODE <br />OF <br />REGULATIONS, <br />INCLUDING THE FOLLOWING: <br />TITLE <br />24, <br />CCR, <br />PART 2, <br />2016 CBC <br />TITLE <br />24, <br />CCR, <br />PART 3, <br />2016 CEC <br />TITLE <br />24, <br />CCR, <br />PART 4, <br />2016 CMC <br />TITLE <br />24, <br />CCR, <br />PART 9, <br />2016 CFC <br />ALL APPLICABLE <br />LOCAL <br />CODES. <br />2. ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL LICENSES, ETC. <br />REQUIRED TO CARRY ON AND COMPLETE THE WORK. PERMIT BY OWNER. <br />3. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, TRANSPORTATION AND <br />PERFORM ALL OPERATIONS NECESSARY FOR ANY REASONABLE INCIDENTAL TO PROPER <br />EXECUTION AND COMPLETION OF ALL "ELECTRICAL WORK" WHETHER SPECIFICALLY <br />MENTIONED OR NOT; ALL AS INDICATED, SPECIFIED HEREIN, AND/OR IMPLIED THEREBY TO <br />CARRY OUT THE APPARENT INTENT THEREOF. <br />4. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERS' <br />LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL BEAR THEIR LABEL <br />WHEREVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY <br />FURNISHED BY THAT AGENCY. <br />5. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZE <br />AND LOCATIONS OF EQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE, <br />CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFY <br />THIS INFORMATION AT THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT <br />AND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH OTHER TRADES. <br />6. CONDUCTORS SHALL BE COPPER CONDUCTORS TYPE THWN UNLESS OTHERWISE <br />NOTED OR REQUIRED BY CODE. <br />7. ALL LUMINAIRES AND BALLASTS SHALL BE CERTIFIED BY THE MANUFACTURER TO <br />THE CALIFORNIA ENERGY COMMISSION. <br />B. FLASH AND COUNTER FLASH ALL ITEMS PASSING THROUGH THE ROOF. ANY ROOF <br />PENETRATIONS WILL BE APPROVED BY THE OWNER. ROOFING MFG. HAS SPECS. AS TO <br />NOT VOID 20 YEAR WARRANTY. <br />9. WORK SHOWN ON THE DRAWINGS TO BE INSTALLED UNDERGROUND SHALL BE <br />INSTALLED AT LEAST 24" BELOW GRADE. BACKFILL IN 6" THICK, PROPERLY MOISTENED <br />LAYERS, SOLIDLY PACKED AND IRON TAMPED TO A DENSITY NOT LESS THAN THAT OF <br />ADJACENT, UNDISTURBED EARTH. RESTORE SURFACES, ROADWAYS, WALKS, CURBS, <br />WALLS, EXISTING UNDERGROUND INSTALLATIONS TO ORIGINAL CONDITION IN AN <br />ACCEPTABLE MANNER. <br />10. THE OWNER RESERVES THE RIGHT TO RELOCATE ALL LIGHTING, OUTLETS AND <br />SWITCHES BEFORE THEY ARE ROUGHED IN AT NO EXTRA COST. <br />11. ALL EXIT SIGNS TO BE UNSWITCHED. <br />NAMEPLATES & IDENTIFICATION: <br />INSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, ETC. <br />NAMEPLATES SHALL BE SECURELY FASTENED TO THE EQUIPMENT WITH #4 PHILLIPS <br />ROUND HEAD CADMIUM PLATED SELF—TAPPING SCREWS, BRASS BOLT, OR WITH A PLASTIC <br />RESIN ADHESIVE GLUE, GOODYEAR "PLIEBOND" OR EQUAL. <br />ELECTRICAL SPECIFICATIONS <br />GENERAL NOTES (CONT.): <br />HVAC UNIT DISCONNECTS: <br />1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR <br />EXACT LOCATIONS OF ALL HVAC UNITS, DISCONNECTS AND DEVICES IN FIELD. VERIFY AND <br />CONFIRM THE ACTUAL MOUNTING LOCATION ON THE HVAC UNIT FOR THE DISCONNECT. <br />2. THE RATING OF THE DISCONNECT SHALL BE SUCH AS TO ENABLE THE LARGEST <br />FUSE SIZE ON THE UNIT NAMEPLATE TO BE INSTALLED IN THE DISCONNECT. PROVIDE <br />FUSES OF THIS RATING. <br />3. FURNISH AND INSTALL ALL LINE VOLTAGE AND LOW VOLTAGE CONDUITS AND LINE <br />VOLTAGE WIRING (LOW VOLTAGE WIRING BY OTHERS) TO HVAC EQUIPMENT AND <br />ASSOCIATED CONTROLS AND DEVICES AS SHOWN ON THE ELECTRICAL AND MECHANICAL <br />PLANS, UNLESS OTHERWISE NOTED. <br />WIRING METHODS: <br />1. ALL WIRING SHALL BE INSTALLED IN STEEL CONDUITS, CONCEALED IN WALL AND <br />CEILING U.O.N. <br />2. MINIMUM CONDUIT SIZE SHALL BE 1/2". MINIMUM ACCEPTABLE CONDUITS ARE <br />A. GALVANIZED RIGID STEEL. <br />B. GALVANIZED STEEL EMT. <br />C. LIQUID TIGHT STEEL FLEX — FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT <br />D. FLEXIBLE STEEL CONDUIT — FOR INDOOR FINAL CONNECTIONS TO <br />MECHANICAL EQUIPMENT (NOT TO EXCEED 36"). <br />E. PVC CONDUIT SCHEDULE 40, UNDERGROUND. <br />3. NMC CABLING SYSTEMS ARE NOT ALLOWED IN THIS BUILDING. <br />4. MC CABLING SYSTEMS ARE NOT ALLOWED IN THIS BUILDING. <br />WIRING DEVICES: <br />UNITS SHALL BE EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS <br />(BROWN, WHITE, GREY, BEIGE OR IVORY) AS SELECTED BY THE ARCHITECT: <br />A. WIRING DEVICES LEVITON # HUBBELL # P & S # <br />SINGLE POLE SWITCH 1221 1221 2OAC1 <br />THREE WAY SWITCH 1223 1223 20AC3 <br />DUPLEX CONV. OUT. 15A 5262 5262 5262 <br />DUPLEX GFI CONV. OUT. GF5262 <br />DEVICE PLATES: <br />1. ALL DEVICE PLATES FOR INDOOR USE SHALL BE SMOOTH NYLON OR APPROVED <br />EQUAL UNLESS OTHERWISE NOTED. ALL DEVICE PLATES FOR OUTDOOR USE SHALL <br />BE RAISED METAL. <br />2. DEVICE COVERS FOR SURFACE MOUNTED BOXES SHALL BE 1/2" RAISED STEEL <br />PLATES. WEATHERPROOF COVERS TO BE SNAP TYPE COVERS. <br />3. DEVICE PLATES FOR TELEPHONE AND COMPUTER OUTLETS TO BE PROVIDED BY <br />OWNER'S VENDOR. ALL TELEPHONE AND COMPUTER SYSTEM WIRING BY OWNER'S <br />VENDOR. <br />I ELECTRICAL SPECIFICATIONS I <br />GENERAL NOTES (CONT.): <br />SUPPORTS: <br />1. FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR ALL <br />ELECTRICAL ENCLOSURES, CONDUITS AND EQUIPMENT. <br />2. ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, <br />TO METAL WITH MACHINE SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION <br />ANCHORS AND MACHINE SCREWS OR BOLTS. <br />GROUNDING: <br />1. GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND <br />SPECIFICALLY INCLUDING SWITCHBOARD, PANELBOARDS, MOTOR CASES, ETC. <br />PANELBOARDS: <br />UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON THE PANEL <br />SCHEDULE, WITH THE NUMBER AND SIZE OF BREAKERS INDICATED ON THE PANEL <br />SCHEDULE. SINGLE POLE, TWO POLE AND THREE POLE BREAKERS SHALL BE BOLT— <br />ON TYPE. THE PANEL DOORS SHALL HAVE FLUSH TYPE LOCKS, ALL LOCKS SHALL BE <br />KEYED ALIKE AND HAVE TYPEWRITTEN DIRECTORIES INDICATING FIXTURES, <br />EQUIPMENT, OR OUTLETS SERVICED BY EACH BREAKER. ALL BUSSING SHALL BE <br />COPPER. <br />WORKING CLEARANCES FOR PANELS & SWITCHBOARDS <br />1. COORDINATE WITH OTHER TRADES TO ENSURE CODE REQUIRED WORKING <br />CLEARANCES, ACCESS, ETC. FOR PANELS AND SWITCHBOARDS PER C.E.C. <br />SECTIONS 110-16 AND 384-4. <br />TESTING: <br />1. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS <br />AND IMPROPER GROUNDS. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY <br />AND GROUNDS BEFORE ANY FIXTURES OR EQUIPMENT ARE CONNECTED AND <br />WHETHER SUCH TESTS INDICATE FAULTY INSULATION OR OTHER DEFECTS, THEY <br />SHALL BE LOCATED, REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE. <br />2. DEMONSTRATE TO THE OWNER AND THE ARCHITECT, THAT THE ENTIRE <br />INSTALLATION IS COMPLETE, IN PROPER OPERATING CONDITION AND THAT THE <br />CONTRACT HAS BEEN PROPERLY AND FULLY EXECUTED. PROVIDE ALL <br />INSTRUMENTS TO MAKE SUCH TESTS. <br />NORTH <br />ELECTRICAL SITE PLAN <br />SCALE: 1/16"=1'-0" (I <br />En ineerin <br />`' <br />50 years <br />4512 Feather River Or "F. Stockton. CA 95219 <br />209-478-8270 1 www.hcs-eng.com <br />® Richard C. Smith, PE richard@hcs-eng.Can <br />❑ Bhupendra Patel, PE bhupendra@hcs-mg.con <br />❑ Elizabeth Aguilar elizabeth@hcs-eng.com <br />PROJECT " 2019247 <br />spl COPYRIGHT 2019 <br />THIS DOCUMENT, AND THE IDEAS AND <br />DESIGNS INCORPORATED HEREIN, AS AN <br />INSTRUMENT OF PROFESSIONAL SERVICE, <br />IS THE PROPERTY OF `apl" AND IS <br />NOT TO BE USED, IN WHOLE OR IN <br />PART, FOR ANY OTHER PROJECT <br />PLANNING■■■ <br />RCHITECTUREN■ ■ <br />m 0 <br />P I <br />ARCHITECTURE PLUS INC. <br />4335—B NORTH STAR <br />WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />A R C Hl T E C T S <br />Q <br />U <br />p <br />Q <br />z ry <br />W <br />Q12 0 <br />W D__ <br />> ry <br />O z <br />ry I-- <br />Q a- 0 <br />N � z <br />— d <br />Q Z Q <br />ry Q <br />o- <br />z <br />0 <br />CI <br />CK <br />a <br />J <br />a <br />rn <br />J <br />a <br />U_ <br />v <br />w <br />J <br />W <br />O <br />Z <br />Q <br />to <br />0 <br />O <br />Z <br />J <br />6 <br />IZ' <br />W <br />Z <br />W <br />C7 <br />QRpF ESSIpy <br />t,�0 Rp C. S "� <br />No. E14303 <br />w Exp. 6-30-21 <br />"C TR <br />Or CALIF p� <br />DATE : AUGUST 2019 <br />JOB NO. : 18-114 <br />DRAWN: BA <br />CHECKED: RCS <br />SHEET: <br />E I I <br />