My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2022 10:26:36 AM
Creation date
2/8/2021 9:29:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #551121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />COUNTY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />QUIK STOP MARKET #551121 <br />1196 W LOUISE AVE, MANTECA <br />May 19, 2021 <br />Single -Walled Non -Pressurized Piping <br />404 <br />CCR 2643(e), 2661(f) <br />Failure to conduct 0.1 gph test on single -walled gravity piping biennially or post repair (pre -1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />122 <br />CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report. <br />OBSERVATION: An inspection was last done on 05/18/2020 and an inspection report was issued identifying <br />information to be submitted to bring this site into compliance. This information was required to be submitted by <br />06/17/2020. This information was received on 09/03/2020, three months late resulting in a non-compliant status for <br />this facility. <br />REGULATION GUIDANCE: An operator that receives an inspection report shall have 30 days to implement the <br />corrections specified in the inspection report and comply with permit conditions. The corrective action shall include <br />all of the recommendations made in the report. The operator shall submit a written response that includes a <br />statement documenting corrective actions taken or proposing corrective actions which will be taken. <br />CORRECTIVE ACTION: Ensure that a written response documenting corrective actions taken or proposed is <br />submitted and all corrections implemented within 30 days of receiving an inspection report. <br />This is a repeat violation, Class Il. <br />202 <br />CCR 2712(i) Failure to retain a paper or electronic copy of the permit to operate at the facility. <br />OBSERVATION: A copy of the current UST operating permit was not found on site. <br />REGULATION GUIDANCE: A copy of the current UST operating permit and all attachments and conditions shall be <br />retained at the facility. <br />CORRECTIVE ACTION: Immediately obtain a copy of the current permit and retain it on site. <br />This is a repeat violation, Class Il. <br />FA0000848 PR0231430 SCO01 05/19/2021 <br />EHD 23-01 Rev. 9/16/2020 Page 4 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.